Part No. CT-1701
OPERATION INSTRUCTIONS
Contour Crimp
CONTROLLED CYCLE
CRIMPING TOOL
Crimps Panduit #10 - #2 AWG
non-insulated P series terminals and
#14 - 10 AWG copper
code conductor lugs.
Includes 5-position, rotating die.
Provides UL Listed and CSA Certified terminations
with applicable Panduit terminals.
COPPER COMPRESSION CONNECTOR
CRIMPING INSTRUCTIONS
1. With the handles in the position,open
depress die release and rotate die to desired
pocket. The pocket will lock in place when
an audible “click” is heard (Die index number
appears to the left of corresponding pocket).
CAUTION: Do not cycle tool unless the
die release button has seated and the die
has locked in place.
Refer to product packaging for selection of
the proper crimp pocket. Place the desired
compression connector in the crimp pocket
(See Fig. 2).
2. Close handles until the connector is held
snugly in position—do not deform the
barrel.
3. Insert the stripped wire into the connector
until the wire stops. Refer to product
packaging for wire strip length.
4. Crimp the connector by closing the handles
until the controlled cycle mechanism
releases. Repeat this operation for the
compression connectors that require more
than one compression. Upon release, the
handles will open automatically and the
crimped connector can be removed.
After crimping, inspect that the crimp is
centered on the barrel in order to achieve
optimal pullout performance.
OPERATION INSTRUCTIONS
PA23829A01
Rev.: 05 3-2017
CT-1701
Figure 1
CRIMP POCKETS FOR Panduit
Compression Connectors.
Refer to product packaging for
wire range and proper crimp
pocket. Crimp pockets are
identified with applicable die
index number.
Cushioned Handle Grips
Manual release lever, push
forward in the event that
controlled cycle mechanism
must be released.
Controlled cycle mechanism
prevents tool from opening
before crimp cycle is complete.
Š Panduit Corp. 2017
Email:
techsupport@panduit.com
EU Website: www.panduit.com/emea
EU Email: emeatoolservicecenter@panduit.com
Technical Support:
Tel: 1-800-777-3300
Panduit Europe • EMEA Service Center
Tel: +31 546 580 452 • Fax: +31 546 580 441
CAUTION: Verify power is “OFF” before
working on wiring with this tool. The
cushioned grips are for the user’s com-
fort, and are not intended to insulate
against shock while working on live
electrical circuits.
Page: 1 of 2
Rotating Crimp Die Wheel
Crimp Die Release Push Button
Figure 2
www.panduit.com
INSPECTION / MAINTENANCE
VISUAL INSPECTION
1. Visually inspect the tool for missing or loose
pins, then close the tool and note the return
action of the handles.
2. Inspect the crimping dies for worn, chipped
or broken edges.
3. If parts are missing, defective or damaged,
contact Panduit Customer Service or
Panduit EMEA Service Center for
information on repair or replacement of tools.
DIE CLOSURE INSPECTION
Die closure is measured by using GO/NO GO
gage members (dimensions listed in Table 1).
1. Clean the crimping dies and gage member surfaces.
2. Close the tool handles until the crimping dies are bottomed and the controlled cycle mechanism
releases. Keep the handles closed together.
3. Using the appropriate gage member, attempt to insert the NO GO gage into the die opening. The NO
GO side may partially enter the die closure but must NOT pass completely through. Perform this test
for all three crimp pockets.
4. Repeat Step 3 with the appropriate GO gage for all three crimp pockets. The GO side must enter
and pass completely through the die closures.
5. If both gage conditions are met, the tool is dimensionally correct. If either condition fails, contact
Panduit Customer Service, or Panduit EMEA Service Center for technical assistance.
PRELOAD FORCE INSPECTION
1. Close the handles until the controlled cycle
mechanism is engaged, but before the
mechanism releases.
2. Apply a force to the handles 1-1/4" (32 mm)
from the end of the handles, until the
controlled cycle release mechanism
releases. Record the reading using a force
gauge.
3. The force required to release the controlled
cycle release mechanism should be a
minimum of 15 pounds-force (67 N). If the
force required is less than 15 pounds-force
(67 N), contact Panduit Customer Service, or
Panduit EMEA Service Center for technical
assistance.
Table 1
NEW TOOLS -
BEFORE PLACING INTO SERVICE:
All Panduit crimping tools are calibrated and inspected before they are
shipped from the factory. All new tools should be inspected before being
used.
New tools are shipped, factory lubricated, in protective packaging. After
inspection, simply clean any excess oil from the crimping dies and place into
service.
When the tool is not in use, keep the handles closed to prevent objects from
becoming lodged in the crimping area. Store the tool in a clean, dry area.
IN-SERVICE TOOLS -
AFTER TOOLS HAVE BEEN IN SERVICE:
It is recommended that each operator of the tool be made aware of-and
responsible for following these maintenance steps.:
In-service tools should be cleaned and inspected at least ONCE A MONTH.
To clean-wipe with a clean cloth.
In-service tools should be lubricated ONCE A WEEK, and after every
cleaning. Lubricate all pins, pivots and bearing surfaces with DOW
CORNINGÂŽMolykote BR2 Plus. Do not use oil excessively.
Be sure to clean any excess oil from the crimping dies before using.
ÂŽ Molykote BR2 Plus is the Registered Trademark
of DOW CORNING
DIE CLOSURE GO / NO GO GAGE MEMBERS - TOOL NO. CT-1701
DIE INDEX
NUMBER
ENGLISH GO / NO GO GAGE MEMBERS METRIC GO / NO GO GAGE MEMBERS
“G” Dia. (GO) “NG” Dia. (NO GO) “G” Dia. (GO) “NG” Dia. (NO GO)
P10 0.099” 0.109” 2,51 mm 2,76 mm
P8 0.179” 0.201” 4,54 mm 5,10 mm
P6 0.217” 0.238” 5,51 mm 6,04 mm
P4 0.273” 0.295” 6,93 mm 7,49 mm
P2 0.351” 0.374” 8,91 mm 9,49 mm
Page: 2 of 2
TROUBLESHOOTING
Š Panduit Corp. 2017
OPERATION INSTRUCTIONS CT-1701


Product specificaties

Merk: Panduit
Categorie: Niet gecategoriseerd
Model: CT-1701

Heb je hulp nodig?

Als je hulp nodig hebt met Panduit CT-1701 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Panduit

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd