Pacific Energy Super Insert LE Handleiding

Pacific Energy Heater Super Insert LE

Lees hieronder de 📖 handleiding in het Nederlandse voor Pacific Energy Super Insert LE (28 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/28
210619-28 SUPER INSERT LE 100002686
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS
MODEL:
SUPER INSERT LE
INSTALLATION
AND OPERATING
INSTRUCTIONS
SERIAL #
SAFETY NOTICE
If this stove is not properly installed, a house
re may result. For your safety, follow the
installation instructions. Contact local
building or re ofcials about restrictions and
installation inspection requirements in your
area.
Meets the US Environmental Protection
Agency's 2020 Particulate Emission
Standards.
Visit www.pacicenergy.net for the most recent version of this manual
2
SUPER INSERT LE 210619-28100002687
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacic Energy, SUPER INSERT LE;
Fireplace Insert wood heater. Please read this entire manual before you install and use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or even death.
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN
THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently.
This may be due to curing of stove paint or fumes caused by accidentally leaving the re door open. Do not
disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house re may result. For your safety, follow
the installation instructions. Contact local building or re ofcials about restrictions and installation
inspection requirements in you area.
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
Rating Label 3 .....................................................................
Efciency and BTU Output 3 ..........................................
Safety 4 ...............................................................................
Chimney Smoke and Creosote Formation 4 ...................
Chimney Fires 4 ..............................................................
To Avoid a Chimney Fire 5 ..............................................
In Case of a Chimney Fire 5 ............................................
Curing of the Paint Finish 5 .............................................
Disposal of Ashes 5 ........................................................
Operation 6 ..........................................................................
Wood Selection 6 ............................................................
DO NOT BURN : 6 ..........................................................
How to Test Your Wood 6 ...............................................
Lighting a re 7 ...............................................................
Normal Operation 7 ........................................................
Convection Blower Operation 8 ......................................
Restarting After Extended or Overnight Burns 8 ............
Proper Draft 8 .................................................................
Ash Removal 8 ................................................................
Maintenance 9 .....................................................................
Door Gaskets - 9 .............................................................
Door Glass - 9 ................................................................
Maintenance Checks 10 ......................................................
Weekly: 10 .......................................................................
Monthly 10 ......................................................................
When Cleaning the Chimney System: 10 .......................
Blower: 10 .......................................................................
Bafe: 10 .........................................................................
Bafe Removal 10 ...............................................................
Removal 10 .....................................................................
Dimensions 11 .....................................................................
Surround Dimensions 11 ................................................
Minimum Fireplace Dimensions 12 .....................................
Hearth Requirements: 12 ................................................
Ember Protection: 13 ......................................................
Optional Leveling Legs 13 ..............................................
Clearances 14 .....................................................................
Minimum Clearances to Combustibles 14 ......................
Installation 15 ......................................................................
Into a Masonry Fireplace 15 ...........................................
Into a Factory Built Fireplace 18 .....................................
Combustion Air 18 ..........................................................
Electrical Supply 19 ........................................................
Fan Cover Removal 19 ........................................................
Surround Assembly and Installation 20 ...............................
Fan Speed Controller Relocation 21 ...................................
Troubleshooting 23 ..............................................................
Firebrick Installation 24 .......................................................
Replacement Parts 26 .........................................................
Table of Contents
3
SUPER INSERT LE 210619-28 100002686
This heater meets the 2020 U.S. Environmental Protection Agency's crib wood emission limits for wood
heaters sold after May 15, 2020 using Method 28R. Under specic test conditions this heater has been
shown to deliver heat at rates ranging from 12,518 to 38,177 Btu/hr.
EPA Certied Emissions 1.8 grams per hour
LHV Tested Efciency 1 77%
HHV Tested Efciency 2 71%
EPA BTU Output 3 12,518 to 38,177 btu/hr
Maximum Wood Length 18 inches
Ideal Wood Length 16-18 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using
CSA B415 Performance testing of solid-fuel-burning heating
appliances and burn rates from the low and high EPA tests
using Douglas Fir dimensional lumber.
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct
air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather
conditions. With practice, you will become procient in operating your heater and will obtain the performance
for which it was designed.
Rating Label
Efciency and BTU Output
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DE
PACIFIC ENERGY.
• CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE,
CONCERNANT LES CODES, RESTRICTIONS ET EXIGENCES D’INSPECTION D’INSTALLATION
DE VOTRE RÉGION.
• INSTALLEZ ET UTILISEZ SEULEMENT DANS UN FOYER PRÉFABRIQUÉ OU EN
MAÇONNERIE. NE RACCORDEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE
DESSERVANT UN AUTRE APPAREIL.
• COMPOSANTS REQUIS POUR L’INSTALLATION : GAINE DE CHEMINÉE COMPLÈTE
CONFORME À CAN/ULC-S635 OU CAN/ULC-S640.
• ALIMENTATION ÉLECTRIQUE : 115 V, 60 HZ, 1.2 AMP. ÉLOIGNEZ LE CORDON ÉLECTRIQUE
DE L’APPAREIL. DANGER : RISQUE D’ÉLECTROCUTION.
• POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. AUCUN PORTE-BÛCHES NI FEU
SURÉLEVÉ - MONTEZ LES BÛCHES DE BOIS DIRECTEMENT SUR L’ÂTRE. REMPLACEZ LA
VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE.
• INSPECTEZ ET NETTOYEZ LA CHEMINÉE RÉGULIÈREMENT - EN CERTAINES CONDITIONS,
DES DÉPÔTS DE CRÉOSOTE PEUVENT SE FORMER RAPIDEMENT.
• UTILISEZ CET APPAREIL SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE.
OUVREZ-LA SEULEMENT POUR ALIMENTER LE FEU. CE POÊLE EST CONÇU UNIQUEMENT
POUR BRÛLER DU BOIS DE CORDE. BRÛLER D’AUTRES MATÉRIAUX PEUT ENDOMMAGER
LE POÊLE OU LE BÂTIMENT.
• COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT TOUT TRAVAIL D’ENTRETIEN SUR
L’APPAREIL.
A) ADJACENT SIDEWALL / PAROI LATÉRALE ADJACENTE 255 MM / 10 IN
B) MANTEL / MANTEAU 305 MM / 12IN
C) TOP FACING / REVÊTEMENT SUPÉRIEUR 305 MM / 12IN
D) SIDE FACING / REVÊTEMENT LATÉRAL 155 MM / 6 IN
E) FIRING SIDE / EPREUVE DU FEU, CANADA 457 MM / 18 IN
FIRING SIDE, U.S.A. 406 MM / 16 IN
F) OTHER SIDES / AUTRES CÔTÉS. 200 MM / 8 IN
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH UNDER THE UNIT, EXTENDING A DISTANCE OF 16IN /
406MM IN FRONT OF THE FIREPLACE OPENING FACE. // INSTALLER UNIQUEMENT SUR UN COEUR NON
COMBUSTIBLE SOUS L’APPAREIL, S’ÉTENDANT À UNE DISTANCE DE 16po / 406mm DEVANT LE FACE
D’OUVERTURE DU FOYER.
• INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND
OPERATING INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA.
• INSTALL AND USE ONLY IN MASONRY OR FACTORY BUILT FIREPLACE.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• COMPONENTS REQUIRED FOR INSTALLATION : FULL FLUE LINER CONFORMING TO CAN/
ULC-S635 OR CAN/ULC-S640. IN U.S.A. FLUE LINER CONFORMING TO UL-1777 OR DIRECT
FLUE CONNECTION ASSEMBLY.
• ELECTRICAL RATING 115V, 60HZ, 1.2 AMP. ROUTE POWER CORD AWAY FROM UNIT.
• DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
• FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE - BUILD
WOOD FIRE DIRECTLY ON HEARTH.
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY. REPLACE GLASS
ONLY WITH CERAMIC GLASS.
• INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE,
CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
• STOVE IS DESIGNED TO BURN CORDWOOD ONLY. BURNING OTHER MATERIALS MAY
CAUSE DAMAGE TO STOVE OR HOME.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
• CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER
INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL
LISTED SOLID WOOD FUEL FIREPLACE INSERT / APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMINÉE
CERTIFIED FOR USE IN CANADA AND U.S.A.
CERTIFIED TO / CERTIFIÉ POUR:ULCS628-93/ UL1482 (2011)
CLEARANCE TO COMBUSTIBLES
ADJACENT SIDE WALL
C# 4001507
260419 SUPER INSERT LE 100002100
Refer to Intertek’s Directory of Building Products for detailed information
MODEL / MODÈLE:
SUPER INSERT LE ALDERLEA T5 INSERT LE
MADE IN CANADA
MANUFACTURED BY:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
DATE OF MANUFACTURE
BC
AD
F
FE
1.8
g/hr
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certied to comply with 2020 crib wood particulate
emission standards, using test Method 28R
.
MINIMUM CLEARANCE TO COMBUSTIBLES (MEASURED FROM FAN COVERS)
DÉGAGEMENT MINIMUM AUX COMBUSTIBLES (MESURÉ À PARTIR DE COUVERTURES DE VENTILATEUR)
SUPER _ ALT5 Insert LE Rating label.


Product specificaties

Merk: Pacific Energy
Categorie: Heater
Model: Super Insert LE

Heb je hulp nodig?

Als je hulp nodig hebt met Pacific Energy Super Insert LE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Pacific Energy

Handleiding Heater

Nieuwste handleidingen voor Heater