Pacific Energy FP16 LE Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Pacific Energy FP16 LE (32 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 23 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
020323-32 FP16 LE 100004090
INSTALLATION
AND OPERATING
INSTRUCTIONS
SAFETY NOTICE
If this Fireplace is not properly installed,
a house re may result. For your safety,
follow the installation instructions.
Contact local building or re ofcials
about restrictions and installation
inspection requirements in your area.
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER.
MODEL:
FP16 LE,
FP16 AR LE
SERIAL #
Meets the U.S. Environmental Protection
Agency's 2020 Particulate Emission Standards
for Cord Wood
Visit www.pacicenergy.net for the most recent version of this manual
TESTED and LISTED to;
CAN/ULC S610 AND UL127
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation / operation of the Pacic Energy, FP16 LE / FP16 AR LE wood burning Fireplace.
SAFETY NOTICE: If this heater is not properly installed, a house re may result. For your safety, follow the installation
instructions. Contact local building or re ofcials about restrictions and installation inspection requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
Contents
Table of Contents 2 ............................................................
Rating Label 3 ....................................................................
Efciency and BTU Output 3 .......................................
Safety 4 ..............................................................................
Chimney Smoke and Creosote Formation 4 ................
Avoiding a Chimney Fire 5 ...........................................
In The Event of a Chimney Fire 5 .................................
Curing of the Paint Finish 5 ..........................................
Operation 6 .........................................................................
Wood Selection; 6 .......................................................
How to Test Your Wood 6 .............................................
DO NOT BURN THESE MATERIALS 6 .........................
Lighting a Fire 7 ............................................................
Basic Operation 8 ........................................................
Restarting After Extended or Overnight Burns 8 .........
Over Firing 8 .................................................................
Proper Draft 8 ...............................................................
Maintenance Checks 9 .......................................................
Weekly: 9 ......................................................................
Monthly 9 .........................................................................
When Cleaning the Chimney System: 9 .......................
Maintenance 10 ..................................................................
Disposal of Ashes 10 ...................................................
Door Glass/Gaskets 11 ................................................
Blowers: 11 ..................................................................
Bafe: 11 ......................................................................
Bafe Removal: 12 .......................................................
Secondary Air Box Cleaning 12 ...................................
Blower Replacement 13 .....................................................
Fireplace Installation 14 ......................................................
Locating your Fireplace 14 ...........................................
Mobile Home Installation notes: 14 .............................
Crate Removal 14 ........................................................
Dimensions 15 ....................................................................
Fireplace Installation Clearances and Dimensions 15 .
Minimum Framing Dimensions 16 ......................................
Framing Kit Installation 17 ..................................................
Assembly 17 .................................................................
Installing the unit into the chase 17 .............................
Chimney Installation 18 ......................................................
Offset Chimney: 19 .....................................................
Masonry Chimney: 20 ..................................................
Combustion Air 21 ..............................................................
Installation: 21 ..............................................................
Convection Blower Wiring 22 .............................................
Ember Protection 23 ..........................................................
Safety Strip 23 .............................................................
Ember Protector 23 ......................................................
Finshing The Chase 24 .......................................................
Finishing / Mantel Clearances 26 .......................................
Mantel Clearances and Dimensions 27 .......................
Firebrick Installation Instructions 28 ...................................
Troubleshooting 29 .............................................................
Parts Diagram 30 ..................................................................
Rating Label Location & Access 31 .....................................
Table of Contents
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
WARNING: this product can expose you to chemicals
including ceramic bers, which are known to the state of
California to cause cancer,and to carbon monoxide, which
is known to the state of California to cause birth defects or
other reproductive harm.
For more information go to www.p65warnings.ca.gov.
This warning is applicable to all
PACIFIC ENERGY FIREPLACE
PRODUCTS
2FP16 LE 020323-32
100004090
EPA Certied Emissions 1.4 grams per hour
LHV Tested Efciency 1 68%
HHV Tested Efciency 2 63%
EPA BTU Output 3 12,200 to 47,000 btu/hr
Peak BTU/Hr Output 4
Maximum Wood Length 17 inches
Ideal Wood Length 16 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
Efciency and BTU Output
This heater meets the U.S. Environmental Protection Agency's 2020 Cord wood emission limits for wood
heaters sold after May 15, 2020 Tested to ASTM 3053.
Under specic test conditions this heater has been shown to deliver heat at rates ranging from
12,200 to
47,000Btu/hr. Emissions testing was performed by PFS-TECO Inc.
For instructions on locating and accessing the Rating label, see page 31.
Rating Label
CLEARANCES TO SIDE AND BACK STANDOFFS/ DÉGAGEMENTS 0 in. / 0 mm
C. CORNER TO SIDEWALL/ COIN AU MUR LAT. 3.1 in. / 79mm
D. FRAMING OPENING/ OVERTURE DE CADRAGE 42 in. / 1.07m
E. CEILING TO UNIT/ DU PLAFOND AU FOYER 33 in. / 838mm
NON-COMBUSTIBLES ONLY IN THE SPACE ABOVE UNIT TO CEILING, NOT INCLUDING
APPROVED FRAMING / NON-COMBUSTIBLES SEULEMENT AU-DESSUS FOYER À PLAFOND
F. BASE OF UNIT TO MANTEL/ BASE DE L’UNITÉ AU MANTEAU
G. EMBER PROTECTION FROM FRONT OF UNIT/
PROTECTEUR de PLANCHER À
L’AVANT DU FOYER 18 in. / 457 mm
H. EMBER PROTECTION TO SIDE OF DOOR /
PROTECTION DE LA COUPE À CÔTÉ DE LA PORTE 8 in./ 203 mm
IN USA: (Type 1 fl oor protector - approved to UL1618)Equal to Minimum 20GA steel
DO NOT REMOVE THIS LABEL/ NE RETIREZ PAS CETTE IQUETTE
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS/ DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES
SN-
100004092 270420
MANTEL HEIGHT MUST BE MEASURED FROM THE BASE OF THE UNIT AS FOLLOWS:
46 1/2”(1.18m) FOR A 4”(102mm) DEEP MANTEL UP TO 50 1/2”(1.28m) FOR A 12”(305mm) DEEP
MANTEL./// LA HAUTEUR DU MANTEAU, MESURÉE DE LA BASE DE L’APPAREIL, 46 1/2 ”(1,18
m) POUR UN MANTEL PROFOND DE 4” (102mm) JUSQU’À 50 1/2 ”(1,28m) POUR UN MANTEL
DEEP 12” (305mm).
***
***
MODEL/ MODÈLE: FP16 LE FP16AR LE
LISTED FACTORY BUILT FIREPLACE, also for use in Mobile Home.
CERTIFIED TO / CERTIFIÉ POUR:
ULC S610-M87 AND UL 127-2011 for CANADA AND U.S.A.
ETL#4001507
Refer to Intertek’s Directory of Building Products for detailed information
•
•
•
•
•
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629,
- CHEMINÉE HOMOLOGUÉE ULC-S-629,
- CHEMINÉE HOMOLOGUÉE ULC-S-629,
- CHEMINÉE HOMOLOGUÉE ULC-S-629,
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629,
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
• LES PARTIES DU FOYER INCORPORANT DES CONDUITS CHAUDS OU FROIDS DOIVENT ÊTRE ENCHÂSSÉES, CONFORMÉMENT AUX IN-
STRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
• CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE POUR LES RESTRICTIONS, PERMIS
D’INSTALLATION ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION.
• NE RACCORDEZ PAS CE FOYER À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
• NE PAS OBSTRUER PAS LES OUVERTURES DEVANT LE FOYER, NI RESTREINDRE L’ALIMENTATION D’AIR NÉCESSAIRE POUR LE FONC-
TIONNEMENT NORMAL DU FOYER, TEL QUE SPÉCIFIÉ DANS LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC
L’APPAREIL. LA PROVISION INADEQUATE D’AIR POUR COMBUSTION, MAI DE VENTILATION ET DILUTION A POUR RESULTAT L’OPERATION
DANGEREUSE DE CECI ET AUTRES APPAREILS.
• VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT, POUR LES PRÉCAUTIONS EXIGÉES LORSQU’UNE CHEMINÉE
TRAVERSE UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES.
• REMPLACEZ LA VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE. • LA SOUFFLERIE CLASSEMENT ELECTRIQUE 115V, 60 Hz, 1.1AMP
• CETTE CHEMINEE n’A pas ETE ESSAYEE AVEC UN UNVENTED JOURNAL DE GAZ A REGLE. POUR REDUIRE LE RISQUE DE FEU OU BLES-
SURE, LE PAS INSTALLE UN UNVENTED JOURNAL DE GAZ A REGLE DANS CHEMINEE.
• UTILISEZ SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. NE L’OUVREZ QUE POUR ALIMENTER LE FEU.
• CE FOYER PEUT ÊTRE INSTALLÉ DANS UNE MAISON PRÉFABRIQUÉE. UTILISER DU BOIS SOLIDE SEULEMENT.
• POUR COMBUSTIBLE SOLIDE SEULEMENT.
• COMPOSANTS OPTIONNELS: KIT DE CONDUITS DE DISTRIBUTION DE CHALEUR (PIÈCE no WODC.RHKA).
• UTILISEZ LES COMPOSANTS SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION DE PACIFIC ENERGY.
MANUFACTURED BY/ FABRIQUÉ PAR :
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
MADE IN CANADA
/ FABRIQUÉ AU CANADA
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certi ed to comply with 2020 particulate
emission standards,
using Cordwood.
Tested to ASTM 3053 1.4g/hr.
DATE OF MANUFACTURE
• ALSO FOR USE IN MANUFACTURED HOMES WITH SOLID WOOD FUEL ONLY
• INSTALL AND USE IN ACCORDANCE WITH THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE
• AREAS OF THE FIREPLACE INCORPORATING WARM OR COLD AIR DUCTS SHALL BE ENCLOSED IN ACCORDANCE WITH THE
INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
• DO NOT OBSTRUCT THE OPENINGS IN FRONT OF THE FIREPLACE OR OTHERWISE RESTRICT SUPPLY AIR NECESSARY FOR NORMAL
FIREPLACE OPERATION AS SPECIFIED IN INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE. INADEQUATE
AIR SUPPLY FOR COMBUSTION, VENTILATION AND DILUTION MAY RESULT IN DANGEROUS OPERATION OF THIS AND OTHER APPLIANCES.
• CHIMNEY SYSTEM MUST BE LISTED TO:
ULC S-629 IN CANADA / UL-103 HT IN USA
ULC S-629 IN CANADA / UL-103 HT IN USA
ULC S-629 IN CANADA / UL-103 HT IN USA
ULC S-629 IN CANADA / UL-103 HT IN USA -
-
-
-
ULC S-629 IN CANADA / UL-103 HT IN USA - SEE LOCAL BUILDING CODE AND MANUFACTURER'S
INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• USE SOLID WOOD FUEL ONLY. OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• BLOWER ELECTRICAL RATING 115V, 60HZ, 1.1AMP • REPLACE GLASS ONLY WITH 5mm CERAMIC GLASS.
• DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.
• THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN
UNVENTED GAS LOG SET INTO FIREPLACE.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. - CONSULT THE OWNER’S MANUAL FOR
FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTANT WITH THE OPERATING
INSTRUCTIONS IN THE OWNER’S MANUAL.
C
D
E
G
F
CAN.
U.S.A.
H
H
3
FP16 LE 020323-32 100004090


Product specificaties

Merk: Pacific Energy
Categorie: Heater
Model: FP16 LE

Heb je hulp nodig?

Als je hulp nodig hebt met Pacific Energy FP16 LE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Pacific Energy

Handleiding Heater

Nieuwste handleidingen voor Heater