Ozito IGP-2018 Handleiding

Ozito Generator IGP-2018

Lees hieronder de 📖 handleiding in het Nederlandse voor Ozito IGP-2018 (24 pagina's) in de categorie Generator. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
PETROL
INVERTER
GENERATOR
2000W MAX. POWER
INSTRUCTION MANUAL
SPECIFICATIONS
Engine: 4-Stroke, OHV, 1-Cylinder
Displacement: 119cc
Max. Power: 2,000W (2min)
Rated Power: 1,800W
Economy Mode Power: 500W
AC Outlets: 2 x 240V ~ 50Hz
Max. Current Output: 7.5A
USB Outlets: 5V, 1 x 1.0A, 1 x 2.1A
Fuel Capacity: 10L (Petrol Unleaded)
Sump Capacity: 0.4L
Sound Pressure Level: 77.9dB (A) @ 7m
IP Rating: IP23
Weight: 22.0kg
IGP-2018
STANDARD EQUIPMENT
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY
YOU MUST RETURN THE PRODUCT TO YOUR NEAREST
BUNNINGS WAREHOUSE WITH YOUR BUNNINGS
REGISTER RECEIPT. PRIOR TO RETURNING YOUR
PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR
CUSTOMER SERVICE HELPLINE:
Australia: 1800 069 486
New Zealand: 0508 069 486
The benefits provided under this warranty are in addition to other rights and remedies which
are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to a
replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this warranty,
however, where you have suffered any additional direct loss as a result of a defective product
you may be able to claim such expenses by contacting our customer service helpline above.
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE HAVE
THE MODEL NUMBER AND DATE OF PURCHASE
AVAILABLE. A CUSTOMER SERVICE REPRESENTATIVE
WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS
YOU MAY HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO Australia/New Zealand (Head Office) 25 Fox Drive, Dandenong South, Victoria, Australia 3175.
ozito.com.au
Inverter Generator
0321
1 YEAR REPLACEMENT WARRANTY*
Your product is guaranteed for a period of 12 months from the original date of purchase. If
a product is defective it will be replaced in accordance with the terms of this warranty. Warranty
excludes consumable parts, for example: valve adapters and accessories.
*This product is intended for DIY use only and replacement warranty covers domestic use.
WARNING
The following actions will result in the warranty being void.
If the tool has been operated on a supply voltage other than that specified on the tool.
If the tool shows signs of damage or defects caused by or resulting from abuse, accidents
or alterations.
Failure to perform maintenance as set out within the instruction manual.
If the tool is disassembled or tampered with in any way.
Professional, industrial or high frequency use.
2000W PETROL INVERTER GENERATOR
4 STROKE 119CC ENGINE
2000W
INVERTER
TECHNOLOGY
2x
I
0
I
0
I
0
240V
1
240V
2
AC SOCKET 1
USB PORTS
AC SOCKET 2
FUEL ECONOMY
ENGINE POWER
OVERLOAD
AC OUTPUT
AC IF O VER LOADE D
RESTART ENGIN E TO RESET
AUT OM AT IC E NGIN E S HU T O FF
REFILL M OTOR OIL
LOW OIL
OFF O N
OFF O N
OFF O N
LOW OIL
AC POWER
2000W PETROL INVERTER GENERATOR
4 STROKE 119CC ENGINE
2000W
INVERTER
TECHNOLOGY
2x
I
0
I
0
I
0
240V
1
240V
2
AC SOCKET 1
USB PORTS
AC SOCKET 2
FUEL ECONOMY
ENGINE POWER
OVERLOAD
AC OUTPUT
AC IF OVERLOADED
RESTART ENG INE T O RESET
AUTOMAT IC ENG INE S HUT OFF
REFILL MOTOR OIL
LOW OIL
OFF ON
OFF ON
OFF ON
LOW OIL
AC POWER
400ml Generator Oil & 200ml Oil
Filler Bottle
15W40
MULTIGRADE OIL
4 S TROKE OVH 119CC
ENGINE OIL
GE N ER AT O R
OI L
400 MILLILIT R ES
2
1.5
1
0.5
E7RTC Replacement Spark Plug &
Spark Plug Wrench
2000W PETROL INVERTER GENERATOR
4 STROKE 119CC ENGINE
2000W
INVERTER
TECHNOLOGY
2x
I
00
I
0
240V
1
240V
2
AC SOCKET 1
USB PORTS
AC SOCKET 2
ECONOMY
ENGINE POWER
OVERLOAD
AC OUTPUT
AC IF O VER LOADE D
RESTART ENGIN E TO RESET
AUT OM AT IC E NGIN S HU T OFF
REFILL M OTOR OIL
LOW OIL
OFF O N
OFF O N
OFF O N
W OIL
AC POWER
ON
O
OHV
PETROL INVERTER GENERATOR
KNOW YOUR PRODUCT
1. LUBRICATION & FUEL
SETUP & PREPARATION
Checking The Oil
The generator is shipped without oil and must be filled before
starting. Oil sump capacity is 400ml.
Always check the oil level before every use. Depending on the
load/usage of the generator, the Generator may require up to
200ml of oil top up every 25 hours.
1. Be sure to check that the generator is on a level surface with
the engine stopped.
2. Remove the dipstick, and
wipe with a clean rag. Check
the oil level by inserting the
dipstick in the filler hole
without screwing it in and
then removing it again.
3. If the oil level is below the hatches on the
dipstick, using the oil filler bottle, refill until
it is just below the max. level. Use premium
quality 4-stroke engine oil. Recommended
SAE30 or 15W40 for most climate
conditions in Australia.
Note: The Oil Alert LED will
automatically illuminate when
the oil level is critically low.
When the LED illuminates,
stop using the generator
immediately and fill according
to instruction above. It is
recommended to check the oil
level before each use and top
up as necessary.
Refer to maintenance schedule for oil replacement
information.
H
OIL
L
LOW
IDEAL
MAX.
2 3
1413 15
64
7
9
10
8
1 5
11 12
1716
WARNING! DO NOT START THE GENERATOR WITHOUT
OIL. THE GENERATOR HAS A SAFETY DEVICE WHICH
WILL PREVENT STARTING WITH NO OIL.
WARNING! WHEN CHECKING THE OIL LEVEL, MAKE
SURE THE OIL IS COOL, FAILURE TO DO SO MAY
RESULT IN BURNS & PERSONAL INJURY.
WARNING! ALWAYS WEAR GLOVES, EYE & HEARING
PROTECTION WHEN OPERATING THE UNIT.
WARNING! READ & UNDERSTAND THE INSTRUCTIONS
& WARNINGS PROVIDED WITH THE GENERATOR
BEFORE OPERATION.
ONLINE MANUAL
Scan this QR Code with your mobile
device to take you to the online manual.
1. Frame/Carry Handles
2. Recoil Starter
3. Economy Mode Switch
4. Status Indicator Lights
5. Fuel Cap
6. AC Power Socket
7. Engine Power Switch
8. USB Ports
9. Grounding Terminal
10. Oil Drain Bolt
11. AC Power Switch
12. Oil Dipstick
13. Spark Plug Lead
14. Choke Lever
15. Fuel Tap
16. Spark Arrestor
17. Air Filter Cover
Fuel Consumption
Load Fuel Consumption Runtime (Full
Tank)
Full Load (2000W) 1950mL/h 5.0 hours
Half Load (1000W) 1200mL/h 8.3 hours
Economy Load
(500W) 720mL/h 13.9 hours
Fuel Stabiliser
Fuel gets old, oxidizes, and breaks down over time. It is
recommended that a fuel stabiliser (not included) is used to extend
the usable life of fuel and help prevent deposits from clogging the
fuel system. Follow the fuel stabiliser manufacturers directions for
correct ratio of stabiliser to fuel.
1. Mix fuel stabiliser and fuel prior to filling the tank by using an
approved fuel container and shaking gently to combine.
Note: To ensure correct amount of fuel stabiliser is added to the
engine, always mix fuel stabiliser with fuel before fueling the tank
rather than adding fuel stabiliser directly into the generator’s fuel
tank.
2. Start and run the engine for at least 5 minutes to allow stabiliser
to treat the entire fuel system.
Grounding Terminal
The inverter generator is
supplied with a grounding
terminal that may reduce the
risk of electric shock in certain
applications.
WARNING! ALWAYS CONSULT A QUALIFIED
ELECTRICIAN BEFORE CONNECTING THE GROUNDING
TERMINAL OR WHEN USING THE GENERATOR FOR
APPLICATIONS OTHER THAN DIRECT CONNECTION OF
APPLIANCES (SUCH AS CONNECTION TO A CARAVAN).
Refuelling The Generator
1. Switch off engine by moving
the engine switch to the OFF
position.
2. Remove the fuel cap by
rotating in a anti-clockwise
direction.
3. Add fuel to the tank (91 RON
Unleaded Petrol). Do not
overfill the fuel tank, check
the fuel gauge on the fuel
tank. Do not use ethanol
blended fuels. Fuel tank
capacity is 10L.
4. After refuelling, make sure the fuel cap is closed properly and
securely.
WARNING! BE CAREFUL NOT TO SPILL FUEL WHEN
REFUELLING. SPILLED FUEL OR FUEL VAPOUR MAY
IGNITE. IF ANY FUEL IS SPILLED, MAKE SURE THE
AREA IS DRY BEFORE STARTING THE ENGINE.
AC
USB PORTS
OVERLOAD
AC OUTPUT
AC POWER
I
0
I
0
ENGINE POWER
OFF ON
OFF ON
2000W
PETROL INVERTER GENERATOR
4 STROKE 119CC ENGINE
E | F
FUEL
GAUGE
WARNING! PETROL IS VERY FLAMMABLE. DO NOT
SMOKE OR CAUSE ANY SPARKS OR FLAMES NEAR
FUEL. MAKE SURE THAT YOU STOP THE ENGINE
& ALLOW IT TO COOL BEFORE REFUELLING THE
GENERATOR. SELECT AN OPEN OUTDOOR AREA FOR
FUELLING & MOVE AT LEAST 3M AWAY FROM THE
FUELLING POINT BEFORE STARTING THE ENGINE.
WARNING! MAKE SURE TO STORE FUEL IN A
APPROPRIATE FUEL CONTAINER & KEEP AWAY FROM
FOOD & DRINK SOURCES.
WARNING! CHECK FUEL LINES, TANK, CAP AND
FITTING FREQUENTLY FOR CRACKS OR LEAKS.
WARNING! ONLY USE RON 91 UNLEADED PETROL. DO
NOT USE DIESEL OR ANY OTHER TYPE OF FUEL.


Product specificaties

Merk: Ozito
Categorie: Generator
Model: IGP-2018

Heb je hulp nodig?

Als je hulp nodig hebt met Ozito IGP-2018 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Generator Ozito

Ozito

Ozito IGP-2018 Handleiding

18 Januari 2023

Handleiding Generator

Nieuwste handleidingen voor Generator