“Factory Reset”
To perform a factory reset, press on the Micro Smart Plug button
during 5 seconds until the LED becomes orange. Release the
button, the LED will blink red/green.
Factory Reset clears the Micro Smart Plug’s memory and set
parameters to their default value.
Warning : Please use this procedure only when the primary controller is missing or otherwise
inoperable.
Resetting the Micro Smart Plug does not mean it has been removed from Z-Wave® network
controller’s memory.
Use the primary controller to remove the Micro Smart Plug from its Z-Wave® network (follow
“EXCLUSION” procedures below), before doing a Factory Reset.
INCLUSION PROCEDURE
To add the Micro Smart Plug into a Z-Wave® network:
1Plug the Micro Smart Plug.
2Put the Micro Smart Plug in “Learning mode”.
3Within 30 seconds put the Z-Wave® Controller in
“Learning mode” (See the Controller user guide for its
own Inclusion procedure).
The Micro Smart Plug will conrm the success of the Inclusion
procedure by blinking its LED in Green.
EXCLUSION PROCEDURE
To remove the Micro Smart Plug from a Z-Wave® network:
1Make sure the Micro Smart Plug is plugged.
2Put the Micro Smart Plug in “Learning mode”.
3Within 30 seconds put the Z-Wave® Controller in
“Learning mode” (See the Controller user guide for its
own Exclusion procedure).
The Micro Smart Plug will conrm the success of the Exclusion
procedure by blinking its LED in Red.
METERING
Micro Smart Plug is able to measure the amount of electric energy
consumed by the load plugged on it. This function is able to return
the power in Watt (W) and the cumulative energy in Watt-hour (Wh)
consumed since the product was installed or since the last reset.
This energy and power reports are accessible through your
gateway’s interface.
ASSOCIATION GROUPS
Using association group, the Micro Smart Plug is able to command
or notify another device of a Z-Wave ® network.
The association groups are set by the Main Controller. Once set,
the association groups allow direct control, between Micro Smart
Plug and associated devices, without involving the Main Controller
in the communication.
The NodOn® Micro Smart Plug proposes 6 association groups:
Group Group Name
1 Lifeline
2 Follow State
3 Follow Complementary State
4 Metering - High Threshold - Set
On/Off
5 Metering - Low Threshold - Set On/Off
6 Metering - Report
Group 1 – Lifeline
Maximum number of devices in group: 5
This group is generally used to report information of the Micro
Smart Plug to the Main Controller of the network.
Group 2 – Follow State
Maximum number of devices in group: 5
When the Micro Smart Plug is switched ON (respectively OFF)
using the local button, it will send ON (respectively OFF) command
to the associated devices. No command is sent if the Micro Smart
Plug is switched ON or OFF wirelessly.
This group is congurable through the parameter 3.
Group 3 – Follow Complementary State
Maximum number of devices in group: 5
When the Micro Smart Plug is switched ON (respectively OFF)
using the local button, it will send OFF (respectively ON) command
to the associated devices. No command is sent if the Micro Smart
Plug is switched ON or OFF wirelessly.
This group is congurable through the parameter 3.
Group 4 - Metering - High Threshold - Set On/Off
Maximum number of devices in group: 5
When the Micro Smart Plug reaches over the high threshold of
power dened by the conguration parameter, it will send OFF or
ON command to the associated devices.
This group is congurable through the parameter 25 and 27.
Group 5 - Metering - Low Threshold - Set On/Off
Maximum number of devices in group: 5
When the Micro Smart Plug reaches below the low threshold of
power dened by the conguration parameter, it will send OFF or
ON command to the associated devices.
This group is congurable through the parameters 26 and 27.
Group 6 - Metering - Report
Maximum number of devices in group: 5
All the meter reports and notications triggered by Metering
parameters will be reported to the devices present in this group.
This group is congurable through the parameters 21, 22, 23 and
24.
CONFIGURATION
The Micro Smart Plug NodOn® offers a wide range of
congurations, which can be set and handled by the Z-Wave®
network Main Controller.
Default State
Parameter Number Default Value Size
1 2 1 [byte]
This parameter denes the status of the Micro Smart Plug after a power outage
or after being plugged.
Value Description
0 OFF
1 ON
2 Status before power outage
Follow State
Parameter Number Default Value Size
3 3 1 [byte]
This parameter allows to enable or disable Group 2 & Group 3.
Value Description
0 Group 2 & Group 3 disable
1 Group 2 enable
2 Group 3 enable
The value may be the sum of available values.
For example, if you want to enable Group 2 & 3, the parameter
value is 1+2=3.
Always On
Parameter Number Default Value Size
4 0 1 [byte]
This parameter forces the Micro Smart Plug status to be ON. While enable it is
not possible to switch OFF the plug (local or wireless).
Value Description
0 Always ON disable
1 Always ON enable
Power Auto-Sending Report
Parameter Number Default Value Size
21 10 1 [byte]
This parameter will send a power report automatically if the power value
changes of x % W (Watt) compared to the last report.
Value Description
0 Power Auto-Polling Report Disable
1 (to 100) Power Auto-Polling Report Enable
if 1% (to100%) variation
Micro Smart Plug Type E
Reference: MSP-3-1-01
Micro Smart Plug Schuko
Reference: MSP-3-1-11
Power supply: 230V AC +/-10% - 50Hz
Self-consumption <1W
Max. power: 1800W continuous (Resistive load)
Radio frequency: 868MHz
Range up to 80 meters outdoor
Range up to 40 meters indoor
Operational temperature: -10°C / 50°C
IP20
Radio protocol: Z-Wave Plus® (500 series)
Dimensions: 46mm (Diameter) x 74mm (H)
Weight: 67g
Warranty: 2 years
USER GUIDE
MICRO SMART PLUG
The NodOn® Micro Smart Plug allows to control (Power ON or
Power OFF) an electrical appliance plugged on it: bedside lamp,
electrical heater, coffee machine, etc.
The NodOn® Micro Smart Plug is compatible with the worldwide
Home Automation standard, Z-Wave®, and all the products
Z-Wave® or Z-Wave Plus® certied from other manufacturers and/
or other applications. All non-battery operated nodes within the
network will act as repeaters regardless of vendor to increase
reliability of the network.
INSTALLATION
1Plug the NodOn® Micro Smart Plug on your power
outlet.
2Plug the electrical appliance, you want to control, on
the NodOn® Micro Smart Plug.
3The Micro Smart Plug allows to switch ON (Power ON)
or switch OFF (Power OFF) the device you want to control.
Switching ON or OFF can be done through the Micro Smart Plug
local button, or any kind of Z-Wave® compatible devices, such as
the NodOn® Octan Remote, the NodOn® Soft Remote or a Home
Automation Gateway.
If the electrical appliance (ex.: bedside lamp) has an ON/OFF button, make sure it’s positioned
on “ON”, in order that the power ON of the Micro Smart Plug will switch ON the lamp.
MICRO SMART PLUG MODES
“Local Control”
The Micro Smart Plug can be switched ON or OFF locally, through
a short press on the local button. By default, the Micro Smart Plug
is switched ON when the LED is green, OFF when the LED is OFF.
“Learning Mode”
Press on the Micro Smart Plug button during 2 seconds until the
LED becomes red. Release the button, the LED will then glow in red.
The Micro Smart Plug is in “Learning mode”.To add or to remove
the Micro Smart Plug from a Z-Wave®
network, follow “INCLUSION”
or “EXCLUSION” procedures below.
If the Micro Smart Plug is not added or removed from a network
within 30 seconds (or if the button is pushed during learning
mode), the Micro Smart Plug will automatically exit learning mode.
Expert remark: NodOn® created a power ecient « Learning
mode ». During this mode, the Micro Smart Plug will send its
« Node Information » (NIF) at regular interval.
If the Primary Controller is battery powered (such as the NodOn
® Octan Remote), rst put
the Micro Smart Plug in “Learning mode”, and then proceed to the INCLUSION/EXCLUSION
procedure of your controller.
To send a single NIF, just triple press on the Micro Smart Plug’s button.
LED state Smart Plug State
Shine Red Learning mode activated
Blink in Green Successful Inclusion
Blink in Red Successful Exclusion
Blink in Orange “Learning mode” Timeout
ON
OFF
<1 s
<1 s
2 s {Shining}
Overload Report
Parameter Number Default Value Size
22 2000 2 [byte]
This parameter will switch off the Micro Smart Plug in case the power is above
x W (Watt) and send an alarm to the primary controller.
This parameter has the highest execution priority between all the metering
congurations for security reason.
Value Description
0 Overload Report Disable (Not Recommended)
1(to 2000) Overload Report enable with a upper limit of 1 W
(to 2000 W)
Energy Auto-Sending Report
Parameter Number Default Value Size
23 1000 2[byte]
This parameter will send a new energy report automatically if the energy value
changes of x Wh (Watt-hour) compared to the last report.
Value Description
0 Energy Auto-Polling Report Disable
1 (to 65535) Energy Auto-Polling Report enable
if 1 Wh (to 65535 Wh) variation
Metering Heartbeat
Parameter Number Default Value Size
24 3600 2 [byte]
Whatever other metering reports, this parameter will send one power and
one energy report to the lifeline every x s (Seconds).
Value Description
0 Metering Pulse disable
1 (to 65535) Metering Pulse enable and send report every
1 s (to 65535 s)
Power High Threshold
Parameter Number Default Value Size
25 20 2 [byte]
This parameter denes the High Threshold power value.
Value Description
0 Power High Threshold disable
1 (to 65535) Power High Threshold enable
with the value from 1 W (to 65535 W)
Power Low Threshold
Parameter Number Default Value Size
26 5 2 [byte]
This parameter denes the Low Threshold power value.
Value Description
0 Power Low Threshold disable
1 (to 65535) Power Low Threshold enable
with the value from 1 W (to 65535 W)
Power Threshold Action
Parameter Number Default Value Size
27 7 1 [byte]
This parameter will dene the Micro Smart Plug actions if the power Low and
High Threshold are reached.
Value Description
0 Power Threshold Action is disable.
1 Power High Threshold Action is enable
and send the command OFF to Group 4
3 Power High Threshold Action is enable
and send the command ON to Group 4
4 Power Low Threshold Action is enable
and send the command OFF to Group 5
12 Power Low Threshold Action is enable
and send the command ON to Group 5
The value may be the sum of available values.
For example, if you want:
- Power High Threshold Action is enable and sent ON to Group
4(3)
- Power Low Threshold Action is enable and sent OFF to Group
5 (4)
the parameter value must be 3+4=7.
DECLARATION OF CONFORMITY
EN61058-1 :2002+A2 :2008
NF C 61-314 :2008+A1 :2010 (Type E)
DIN VDE 0620 -1: 2013 (Schuko)
DIN VDE 0620 -2-1: 2013 (Schuko)
EN301489-1 V1.9.2
EN301489-3 V1.6.1
EN300220-2 V2.4.1
2012/19/EC WEEE Directive
Hereby, ID-RF SAS declares that the RE type MSP-3-1-01 and
MSP-3-1-11 are in compliance with RED 2014/53/EU, Directive
1999/5/EC and RoHS 2011/65/EU.
The full text of the EU DoC is available at the following internet
address:
www.nodon.fr/support/NodOn_MicroSmartPlug_ZWave_CE.pdf
WARNING!
Unplug the product only when it is powered OFF.
Do not plug the products one behind the other.
Do not use the product in a high humidity area.
The product must be easy to access once plugged.
LOGOTYPE
This product is compliant with all relevant
European standards.
When sorting your waste, please observe the
disposal regulations in force. Please place your
waste in the facilities provided for that purpose
and with all due respect for the environment.
This product must be used indoor only.
This product uses a wireless communication
protocol.
This product must not be in contact with water.
This product must not be exposed to a
temperature higher than 50°C.
This product must not be exposed to any kind
of re or heat source.
This product must not be exposed to a
temperature lower than -10°C.
This product is compatible with
Z-Wave® and Z-Wave Plus® protocol.
ADDRESS
NodOn® by ID-RF:
ID-RF SAS
121 rue des HĂŞtres
45590 St CYR EN VAL (FRANCE)
AFTER SALES
www.nodon.fr section “support”
contact@nodon.fr
For user guides in other languages, please visit
www.nodon.fr/notices
ALARMS
The NodOn® Micro Smart Plug embeds Smart Alarm management
features, in order to react to different kinds of notications and
events (According to “Notication V1” command class).
Up to 8 Alarms can be congured, through conguration
parameters #5 to #20.
For each Alarm, the set-up is done through 2 conguration
parameters, as below:
Alarm Number Alarm Type Cong.
Parameter
Alarm Specications
Cong. Parameter
1 5 6
2 87
3 9 10
4 11 12
5 13 14
6 15 16
7 17 18
8 19 20
Parameter # Default Value Size
5/7/9/11/13/15/17/19 0 2 [byte]
This parameter is to set the Alarm X Type
Value Description
Use the Home Automation Gateway interface or our Alarm set-up form to dene
the value corresponding to your need*.
Parameter # Default Value Size
6/8/10/12/14/16/18/20 0 4 [byte]
This parameter is to set the Alarm X Specications.
Value Description
Use the Home Automation Gateway interface or our Alarm set-up form to dene
the value corresponding to your need*.
*In order to congure properly each alarm, please use your Home
Automation Gateway interface or our online form at :
www.nodon.fr/support/msp3/alarm
Over the Air Firmware Update (OTA)
The Micro Smart Plug can update its rmware using a Z-Wave
Plus® compatible gateway installed in your network.
During the update the LED blink alternately from green to red
When the LED is blinking, the product can’t be switched ON or OFF
locally or by radio.The OTA procedure last few minutes.
At the end of the update the product will automatically restart.
Note: After the update, the Micro Smart Plug will keep its Node ID and network pairing.
Do not unplug the Micro Smart Plug during the OTA. Do not press on the local button neither.
For more information please check your gateway user manual.
COMMAND CLASS
The NodOn
® Micro Smart Plug supports the following Command
Class :
COMMAND CLASS VERSION
All switch V1
Application status** V1
Association V2
Association Group Information V1
Basic*** V1
Binary Switch V1
Conguration V1
Device Reset Locally V1
Firmware Update Meta Data V2
Indicator V1
Manufacturer Specic V2
Meter V4
Notication V4
Power Level V1
Protection V2
Version V2
Z-Wave® Plus info V2
** Controlled only (not supported)
*** Controlled AND supported


Product specificaties

Merk: NodOn
Categorie: Niet gecategoriseerd
Model: Micro

Heb je hulp nodig?

Als je hulp nodig hebt met NodOn Micro stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd NodOn

NodOn

NodOn Micro Handleiding

7 November 2022

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd