Nexa CMA-968 10Y Handleiding


Bekijk gratis de handleiding van Nexa CMA-968 10Y (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 115 mensen en kreeg gemiddeld 4.4 sterren uit 58 reviews. Heb je een vraag over Nexa CMA-968 10Y of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
LED
STATUS
INDIKERING
Grön
Enheten är ok och i drift
LED blinkar var 48e sekund
Röd
Hög CO halt
Låg batterispänning
LED blinkar och larmet ljuder 4 ggr var 5e sekund
LED blinkar och larmet ljuder kort en gång i minuten
Gul Internt fel
Enheten behöver bytas ut
LED blinkar och larmet ljuder kort 2 ggr en gång i minuten
LED blinkar och larmet ljuder 3 ggr var 48e sekund
Gul LED
Röd LED
Grön LED
TEST/PAUS-knapp
CMA-968/10Y
CO-VARNARE
TEKNISK DATA
CMA-968/10Y
Strömkälla 3V CR-17335 (litium, inbyggt)
Batteritid 10 år
Drifttemperatur -10°C till +40°C
Luftfuktighet 10 till 90% RH
Larmsignal 85 dB(a) @ 1m
Standard EN 50291-1:2010+A1:2012
Mått (B x D x L) 40 x 30 x 75 mm
CMA-968/10Y är en liten och nätt varnare som detekterar
kolmonoxid (CO)
och ger en tidig varning om koncentrationen
i inomhusmiljön överstiger farliga nivåer.
Kolmonoxid är en osynlig och luktfri giftig gas som uppstår
vid ofullständig förbränning av bland annat kol, gas, olja,
bensin och trä.
Typiska riskkällor kan vara kakelugnar, gasspisar, grillar,
kaminer och olika typer av gasvärmare.
PLACERING
Helstr en CO-varnare installeras i varje rum som
innehåller en potentiell lla till kolmonoxid r att
kunna få en
tidig varning för hög halt av kolmonoxid.
SVENSKA
Kolmonoxid har samma densitet som varm luft och
varnaren kan därför monteras på olika ställen.
Om varnaren monteras vägg bör den placeras över
dörr/fönster höjd men minst 150 mm från taket.
Vid takmontering bör den placeras minst 300 mm från
vägg.
Varnaren bör placeras mellan 1 m och 3 m från
potentiell källa. Om det finns en skiljevägg i ett rum, bör
varnaren placeras på samma sida som den potentiella
källan.
I rum med sluttande tak skall varnaren placeras i den
högsta delen av rummet.
Undvik att placera varnaren
i dammiga och fuktiga miljöer
där luftcirkulationen runt varnaren kan blockeras
i direkt anslutning till dörrar och fönster
direkt ovanför diskbänk, spis och ugn
i direkt närhet av luftkonditionering / luftvärmepump
INSTALLATION
CMA-968/10Y kan användas fristående, placerad
bord eller skåp, eller monteras fast på vägg eller i tak
med medföljande skruv och plugg.
CO-varnaren aktiveras när den monteras på vägg eller
tak, vid fristående användning aktiveras den manuellt
med den medföljande monteringsskruven som då förs
uppåt i fästhålet.
DRIFT
CO-varnaren utför regelbundet självtest för att
säkerställa funktion. LED-indikeringar visar aktuell
status för enheten, se tabell.
TEST/PAUS KNAPP
När larmet ljuder kan det pausas tillfälligt under 10
timmar genom att trycka ned TEST/PAUS-knappen
under 2 sekunder.
Om CO halten överstiger 30 PPM går det ej att pausa
larmet, se åtgärder vid larm.
TESTA
CO-varnaren bör testas regelbundet, minst en gång i
månaden för att säkerställa funktionen.
Tryck och håll inne TEST/PAUS-knappen i 3 sekunder.
d LED skall då blinka och larmet ljuda kort 4 ggr,
testläget avslutas därefter automatiskt.
AVAKTIVERING
När CO-varnaren har uppnått maximal livslängd (10 år)
eller om internt fel har uppstått skall den avaktiveras.
1. Bryt loss den lilla plastfliken på baksidan av CO-
varnaren med en liten skruvmejsel.
2. Sätt plastfliken i det rektangulära spåret och tryck det
därefter nedåt för att avaktivera enheten.
3. CO-varnaren skall därefter lämnas till återvinning av
elektronikskrot enligt WEEE direktivet.
ÅTGÄRDER VID LARM
1. Utrym omedelbart rummet som larmet avser, öppna
fönster/dörrar och vädra om möjligt.
2. Stäng om möjligt av misstänkta källor som kan vara
upphov till larmet.
3. Ring räddningstjänst
RESPONSTIDER
CO NIVÅ
RESPONSTID
50 ppm
60-90 minuter
100 ppm
10-40 minuter
300 ppm
< 3 minuter
NEXA AB, DATAVÄGEN 37B, 436 32 ASKIM, SWEDEN
info@nexa.se | www.nexa.se
INDIKERINGAR
CO LEVEL
RESPONSE TIME
50 ppm
6090 minutes
100 ppm
1040 minutes
300 ppm
< 3–40 minutes
LED
STATUS
INDICATION
Green
The unit is OK and operating
LED flashes every 48 seconds
Red
High CO level
Low battery charge
LED flashes and the alarm sounds 4 times every 5 seconds
LED flashes and the alarm sounds briefly once a minute
Yellow
Internal error
The unit needs to be replaced
LED flashes and the alarm sounds briefly twice a minute
LED flashes and the alarm sounds 3 times every 48 seconds
Yellow
Red LED
Green
TEST/PAUSE
CMA-968/10Y
CO SENSOR
TECHNICAL DATA
CMA-968/10Y
Power supply 3V CR-17335 (lithium, built-in)
Battery lifetime 10 years
Operating temp. -10°C to +40°C
Ambient humidity 1090% RH
Alarm signal 85 dB(a) @ 1 m
Standard EN 50291-1:2010+A1:2012
Dimensions (W x D x L) 40 x 30 x 75 mm
The CMA-968/10Y is a neat little sensor that is designed to
detect carbon monoxide (CO) and it issues an early warning
if the indoor concentration of the gas reaches dangerous
levels.
Carbon monoxide is an invisible and odourless gas that
arises from the incomplete combustion of fuels such as coal,
gas, oil, petrol and wood.
Typical sources of risk include wood-burning stoves, gas
cooking ranges, fireplaces and different types of gas-fired
heaters.
PLACEMENT
Ideally, a CO sensor should be installed in every room that
contains a potential source of carbon monoxide to ensure
ENGLISH
Carbon monoxide has the same density as hot air and
the sensor can therefore be installed in different places.
If the sensor is mounted on a wall, it should be
positioned above door/window height, but at least 150
mm from the ceiling.
When fitted on the ceiling, it should be positioned at
least 300 mm from walls.
The sensor should be positioned 13 m from potential
sources of CO. If there are dividing walls in a room,
make sure to position the sensor on the same side as
the potential source.
In rooms with an angled ceiling, the sensor should be
positioned at the highest point in the room.
Avoid placing the sensor
in dusty and humid environments
in places where the air circulation around the sensor
can be blocked
immediately next to doors and windows
directly above sinks, cooking ranges and ovens
in the immediate vicinity of air conditioning units/hot
air pumps
INSTALLATION
The CMA-968/10Y can be used as a free-standing
device, placed on a table or cabinet, or affixed to a wall
or ceiling using the screw and plug supplied.
The CO sensor is activated automatically when it is
installed on a wall or ceiling. When used as a free-
standing device, it must be activated manually by
pressing the installation screw supplied upwards in the
installation hole.
OPERATION
The CO sensor performs a regular self-test to ensure
that it is functioning correctly. The LED indicator shows
the status of the unit, see the table below.
TEST/PAUSE BUTTON
When the alarm sounds, it can be paused temporarily for
10 hours by pressing the TEST/PAUSE button for 2
seconds.
It is not possible to pause the alarm if the CO level
exceeds 30 PPM see “Actions in the event of an alarm”
TEST
The CO sensor should be tested regularly, i.e. at least
once a month, to ensure it is functioning correctly.
Press the TEST/PAUSE button and hold it in for 3
seconds. The red LED should then flash and the alarm
sound briefly 4 times. The test status will then be
discontinued automatically.
DEACTIVATION
When the CO sensor has reached its maximum service
life (10 years), or if an internal error has occurred, it must
be deactivated.
1. Use a small screwdriver to remove the small plastic
tab on the rear of the CO sensor.
2. Insert the plastic tab into the rectangular slot and
then press it down to deactivate the unit.
3. The CO sensor must then be disposed of as
electronic scrap for recycling, in accordance with the
WEEE directive.
ACTIONS IN THE EVENT OF AN ALARM
1. Immediately evacuate the room to which the alarm
applies; open doors and windows and air the room
out if possible.
2. If possible, shut off any sources that you suspect
may have triggered the alarm.
3. Call the emergency services
NEXA AB, DATAVÄGEN 37B, 436 32 ASKIM,
SWEDEN
info@nexa.se | www.nexa.se
INDICATIONS
RESPONSE TIME


Product specificaties

Merk: Nexa
Categorie: Niet gecategoriseerd
Model: CMA-968 10Y

Heb je hulp nodig?

Als je hulp nodig hebt met Nexa CMA-968 10Y stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Nexa

Nexa

Nexa Bridge X Handleiding

23 September 2024
Nexa

Nexa MGDR-3500/SET Handleiding

23 September 2024
Nexa

Nexa MWTT-2 Handleiding

23 September 2024
Nexa

Nexa MWTE-1 Handleiding

23 September 2024
Nexa

Nexa LDR-075 Handleiding

26 Maart 2024
Nexa

Nexa MYCR-2 Handleiding

26 Maart 2024
Nexa

Nexa WT-1 Handleiding

26 Maart 2024
Nexa

Nexa WTE-2 Handleiding

26 Maart 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Beper

Beper 90.071 Handleiding

14 September 2025
Qoltec

Qoltec 50685 Handleiding

13 September 2025
70mai

70mai X200 Omni Handleiding

13 September 2025
Alluserv

Alluserv VL2020S Handleiding

13 September 2025
VOREL

VOREL 80308 Handleiding

13 September 2025
VOREL

VOREL 80307 Handleiding

13 September 2025
K&K Sound

K&K Sound M8000 Handleiding

13 September 2025
Maginon

Maginon RAG-1 Handleiding

13 September 2025