Revision C
Nectre Big Bakers Oven
Installaon Instrucons
Keep these instrucons for future reference
Glen Dimplex Australia proudly supports the acvies of Landcare Australia through its membership of the AHHA
1
CONTENTS
1. INSTALLATION ................................................................... 1
1.1. IMPORTANT INFORMATION .................................... 1
1.2. INSTALLING THE HEATER ......................................... 2
1.2.1. Posioning the Heater 2 ........................................
1.2.2. Standard Installaon ........................................... 2
1.2.3. Corner Installaon 2 ..............................................
1.2.4. Floor Protector .................................................... 2
1.3. REDUCING CLEARANCES TO COMBUSTIBLES .......... 3
1.4. INSTALLING THE BYPASS DAMPER HANDLE ............ 3
1.5. INSTALLING THE FLUE .............................................. 4
1.6. INSTALLING FIRE BRICKS .......................................... 4
1.7. INSTALLING FIREBOX SIDE SHIELDS ......................... 4
1.8. INSTALLING BAFFLE PLATE 5 ......................................
1.9. INSTALLING TOP AIR CONTROL HANDLE ................. 5
1.10. TECHNICAL DRAWINGS 5 ...........................................
1. INSTALLATION
1.1. IMPORTANT INFORMATION
The unit must be installed according to all manufacturers’
instrucons included in manual. The manufacturer is not this
liable for installaons that do not meet the requirements
outlined in this manual.
Most building regulatory authories in Australia require any
wood heater installaon to comply with Installaon Standard
AS/NZS 2918. Dierent states and councils may have varying
regulaons. Check local building regulaons before installing
the appliance.
All Nectre wood heaters have been tested to ensure they will
meet the appropriate safety standard requirements if the
instrucons in this manual are followed. As the safety and
emissions performance can be aected by altering the
appliance, no modicaons are allowed without wrien
permission from the manufacturer.
WE RECOMMEND THAT THE INSTALLATION OF YOUR NECTRE
WOOD HEATER BE CARRIED OUT BY A QUALIFIED INSTALLER.
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE
INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE
APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING
CODE OR CODES.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED
FOR COMPLIANCE WITH AS/NZS 4012 & AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM
COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS
CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED
IN THE FIRST INSTANCE.
CAUTION: CRACKED AND BROKEN COMPONENTS, EG. GLASS
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION
UNSAFE.
THE INSTALLATION INSTRUCTIONS IN THIS MANUAL
APPLY TO THE NECTRE BIG BAKERS OVEN.
2
1.2. INSTALLING THE HEATER
1.2.1. Posioning the Heater
Review the necessary clearances specied in this secon
before considering where to posion the heater.
Also check the praccability of installing the ue system in
relaon to any obstrucng roof beams before posioning the
heater.
The clearance distances can only be reduced if the
surrounding walls are made of non-combusble material such
as stone, brick or concrete. If non-combusble material,
distance can be reduced to 100 mm. Alternavely, shielding of
the wall(s) can reduce clearances (refer to next secon for
more detail).
1.2.2. Standard Installaon
Dimensions given in the image below represent the minimum
clearance (in millimetres) to combusble materials.
Side clearance 325mm =
Rear clearance = 125mm
1.2.3. Corner Installaon
Dimensions given in the image below represent the minimum
clearance (in millimetres) to combusble materials.
Corner clearance = 275mm
1.2.4. Floor Protector
Unless the heater will be standing on a heat resistant oor
such as concrete slab with slate or les, it will be necessary to
provide a oor protector.
The minimum required dimensions for the oor protector are
shown in the previous images. It must extend no less than
300mm in front of the door opening, no less than 200mm
either side of the door opening and extend under the heater.
Minimum dimensions for the oor protector are 900mm wide
by 900mm deep. It may be desirable, for example aesthec
reasons, for the oor protector to be larger than these
minimum dimensions.
The oor protector shall be constructed of n -combusble on
material no less than 15mm thick and with a thermal
conducvity not greater than 0.33W/m °K, eg. compressed
cement sheet.
The oor protector may be laid directly on the combusble
oor.
For more details and variations on oor protectors refer to
AS/NZS 2918 Clause 2.2, 3.3.1, & 3.3.2.


Product specificaties

Merk: Nectre
Categorie: Heater
Model: Big Bakers Oven

Heb je hulp nodig?

Als je hulp nodig hebt met Nectre Big Bakers Oven stel dan hieronder een vraag en andere gebruikers zullen je antwoorden