APPLY SERIAL NUMBER LABEL FROM CARTON
Serial No.
XXXXXX000000
MODEL NO.
N415-0175 APR 17.14
BUILT–IN UNIT INSTRUCTION GUIDE
Please use this manual in conjuncon with your main manual to properly assemble your built-in grill. Refer to
the main manual for operang, cleaning, and maintenance instrucons.
WARNING! This grill is designed for enclosures only, and must be installed and
WARNING!
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. A exible metal connector is included to simplify the
installaon of the unit. Connect this exible metal connector to the are ng on the end of the manifold.
Connect the other end of the connector to the gas piping. Ensure that the connector does not pass through a
wall, oor, ceiling or paron, and is protected from damage. Do not use a hose to connect the unit except to
connect the cylinder regulator to the piping system. It must be connected with rigid pipe, copper tube or an
approved exible metal connector which complies with Z21.4 /CSA 6.10.
The installaon must comply with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the
Naonal Fuel Gas code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner,
a separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon. If the enclosure is to house a propane cylinder, the tank poron of the enclosure must be venlated
according to local codes, and must not have communicaon with the cavity used to enclose the gas grill. A
propane tank can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must have
both of the following:
1. At least one unobstructed venlaon opening on the exposed exterior side of the enclosure located within
5 in (127 mm) of the top of the enclosure. The opening must have a total free area of more than 20 in
2
(130
cm2)
for a 20 lb (9.1 kg) cylinder and 30 in2 (195 cm2) for a 30 lb (13.6 kg) cylinder.
2. At least one venlaon opening on the exposed, exterior side of the enclosure located 1 in (25.4 mm) or less
from the oor level. The opening must have a total free area of more than 10 in2(65 cm2) for a 20 lb (9.1 kg)
cylinder and 15 in2(100 cm2) for a 30 lb (13.6 kg) cylinder. The upper edge must be no more than 5 in (127
mm) above the oor level.
www.napoleongrills.com
Napoleon Group of Companies
Product specificaties
| Merk: | Napoleon |
| Categorie: | Barbeque / Contactgrill |
| Model: | BUILT-IN ULTRA CHEF BIU405RB |
Heb je hulp nodig?
Als je hulp nodig hebt met Napoleon BUILT-IN ULTRA CHEF BIU405RB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Barbeque / Contactgrill Napoleon
Napoleon LA 300RB Handleiding Napoleon BIG32 Handleiding Napoleon PRESTIGE 665 Handleiding Napoleon TQ3225 Handleiding Napoleon BIB18 Handleiding Napoleon R425 Handleiding Napoleon ULTRA CHEF 405 Handleiding Napoleon PHANTOM PRESTIGE 500 Handleiding
Alle Napoleon Barbeque / Contactgrill handleidingen
Populair in Barbeque / Contactgrill
Handleiding Barbeque / Contactgrill
Nieuwste handleidingen voor Barbeque / Contactgrill
Firefriend BQ-6850 Handleiding Burnhard Nero Pizza oven Handleiding Perel BB100111 Handleiding Nova 110600 Felice grill 5 in 1 Handleiding BonFeu Bonsolo Handleiding Tepro 1065N - Key West Handleiding Outdoorchef City P420 G Handleiding Outdoorchef Chelsea 420 G Handleiding Outdoorchef Australia 415 G Handleiding Outdoorchef Gourmet Check Pro Handleiding