Myson ELECTRIC UNDERFLOOR HEATING Handleiding

Myson Verwarming ELECTRIC UNDERFLOOR HEATING

Lees hieronder de đź“– handleiding in het Nederlandse voor Myson ELECTRIC UNDERFLOOR HEATING (16 pagina's) in de categorie Verwarming. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Important: Please read carefully on receipt
of product and keep in a safe place.
MYSON
heatingthroughinnovation.
ELECTRIC
UNDERFLOOR HEATING.
INSTALLATION MANUAL
APRIL 2013
Contents
1.0 General Information 03
2.0 Preparation 04
3.0 Measuring the Mat and Installation 05
4.0 Measuring Values/Resistance with the Multimeter 09
5.0 Connecting the Thermostat 10
6.0 Thermostat User and Installation Guide 10
7.0 Electrical Connection 13
8.0 Technical Data 14
03Electric Underfloor Heating
1.0 General Information
The MYSON mat is manufactured from high
quality, durable materials. To guarantee that your
product functions optimally there are a few points
of attention which are described in the installation
manual. We can only offer you the full guarantee
if the mat is correctly installed in accordance with
the installation manual. Carefully read the
instructions prior to installation and ensure that
you have the correct tools and materials.
PLEASE NOTE: The electrical installation MUST BE carried out by a qualified electrician.
2
2
2
lBefore installing check if the heating mat is the
right size for the floor area to be heated and that
there is sufficient electrical capacity (Amps)
available. The mat should not be positioned over
expansion joints.
lIf multiple mats are installed in an area then a
shared power point can be installed so that only
1 power cable runs to the thermostat. Maximum
capacity of the thermostat is 16 Amps. The
thermostat should be installed by a qualified
electrician. The power supply must be turned off
during installation.
lThe MYSON mat consists of a heating cable of
8-9 Watts per metre that is equally distributed
and connected to a glass fibre net with an
inter-loop distance of approximately 70mm.
lEach mat is tested at the factory and has a unique
inspection card. Every mat is tested at 4000 volt.
You must check the mat after each installation
phase, in order to know at which phase any
defect occurs (section 4.0).
lThe heating cable, attached to the grey glass
fibre net, must NOT be broken. The mats must
NOT be laid over each other and the heating
cables must NEVER cross each other. The cable
junction (where the power supply cable joins the
heating cable) is just within the heating mat and
is marked.
lThe mat has 1 connecting cable, which is 5
metres in length. The connector cable MUST
NOT be shortened by more than 3 metres, there
must therefore always be at least 2 metres of
connecting wire left. The power supply must be
turned off during installation.
lThe heating mat is 3 - 4 mm thick and must be
incorporated in an adhesive or screed suitable for
floor heating. Check the manufacturer’s data.
lA distance from the wall of 100mm should
generally be adhered to. The mat may never be
installed under fixed objects like wall units,
kitchen units, baths or showers and must be able
to give off its warmth unimpeded.
lThe MYSON mat may only be incorporated into
the free floor/wall areas. As many bathrooms
consist mainly of a small free floor area the mat
may only be installed as supplementary heating.
Please contact your heating engineer who will
advise the heating requirement of the room.
lThe sensor MUST be installed in the middle of a
cable loop for optimal temperature registration.
Ensure that the sensor is installed well clear (min.
500mm) of hidden radiator and water pipes,
drains and electrical wiring.
lThe sensor MUST always remain in the sensor
pipe. Cap the end of the pipe to avoid the sensor
getting stuck during installation. If the sensor
ever needs to be replaced it can then easily
be removed.
lA sufficiently strong and thick compression
resistant floor, with or without reinforcing, must
be applied on wood and insulation. If this is not
the case please contact Customer Services and
enquire about our other products.
lThe electric heating mat is guaranteed for 10
years. The thermostat is guaranteed for 2 years.
The guarantee does not apply to damage caused
by external factors and/or incorrect installation.
lIn compliance with the EU Directive
2006/66/EC, the button cell battery located on
the printed circuit board inside this product,
can be removed at the end of the product life,
by professional personnel only.
MAT THERMOSTAT


Product specificaties

Merk: Myson
Categorie: Verwarming
Model: ELECTRIC UNDERFLOOR HEATING

Heb je hulp nodig?

Als je hulp nodig hebt met Myson ELECTRIC UNDERFLOOR HEATING stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Verwarming Myson

Handleiding Verwarming

Nieuwste handleidingen voor Verwarming