BA 873010rlc N;DE,GB -23247- 2013.01-- V01 ED
INSTRUCTION MANUAL DIMMER [RLC]
Technical Features
Safetey instructions
Supply voltage
230 V, 50Hz
CAUTION!! DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!
Installation and assembly of electrical equipment must be carried out only by professional electrician!
Connect the supply voltage/frequency as stated on the product!
Disconnect device from power supply for wiring and installation purposes! Check power supply is disconnected!
Defective devices have to be put out of service immediately!
Warranty void if housing opened by unauthorised person!
The electronic circuit is protected against a wide range of external influences.
Incorrect operating may occur if external influences exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with local building and electrical codes!
Power consumption
3 VA
Suitable type of lamps
Incandescence and halogen lamps
LOAD
Incandescence, 230V Halogens &
LV Halogens with Electronic transformer
15 400– W
Halogens with Ferromagnetic
transformer
20 250– W
Max. number of pushbuttons
3 lighted pushbuttons & unlimited
non-lighted pushbuttons
Dimensions
45 x 45 x 12 mm
Weight
40 g
Important Note
Permitted ambient temperature
0º +40ºC…
When calculating the max. loads please take into account power dissipation of transformers:.
For conventional transformers ~ 20% power dissipation / For electronic transformers ~ 2% power dissipation
For all transformers and lamps, please take into accountthe specifications of the manufacturer !
Storage temperature
- 30º… +70ºC
Type of protection
IP20 according to
DIN EN 60529
Conformity with Standard
DIN EN 60669-2-1
Description / Installation / Operation
Wiring Diagram
Description
Small size dimmer, for flush- mounting (e.g. behind standard pushbutton)
For leading or trailing edge dimming.
Automatic detection of the load type.
Protected against overload and short -circuit. Builtin heat protection.
Controlled by pushbutton.
With or without memory.
Suitable for R, L & C loads:
- Incandescent & 230V halogen lamps (R)
- ) LV Halogen lamps with Ferromagnetic transformer (L
- LV Halogen lamps with Electronic transformer (LC)
For all transformers and lamps, please take into account the specifications of the manufacturer!
Installation
C AUTION! Do not connect different types of lamps / loads to the same dimmer!
1 Disconnect installation frompower supplyand cpower supply is disconnected heck that .
2 Install the dimmer according to the wiring diagram.
3 Make sure the loads are connectedproperand ly reconnect power supply. The lamps flicker.
(This indicates that the dimmer has done the automatic load type detection)
4 The dimmer is ready for use.
Operation
Press shortly the pushbutton to switch the lamps on and off!
=> Switch on „No Memswitches on with max. brightness.“ = Lamp(s)
=> (s) Switch on „Mem“ = Lampswitches on with the brightness of the last switch off
With a long press you can dim!
(*)Only for very inductive loads necessary
Example:
Product specificaties
| Merk: | Muller |
| Categorie: | Dimmer |
| Model: | 873010 |
Heb je hulp nodig?
Als je hulp nodig hebt met Muller 873010 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Dimmer Muller
12 Februari 2024
Handleiding Dimmer
Nieuwste handleidingen voor Dimmer
28 December 2025
25 December 2025
8 December 2025
8 December 2025
7 December 2025
6 December 2025
3 December 2025
1 December 2025
18 November 2025
11 November 2025