Mitsubishi DXKM07Z6-W Handleiding


Pagina's 28 Engels Airco

Bekijk de handleiding van Mitsubishi DXKM07Z6-W gratis online of download de PDF. 93 mensen vonden deze handleiding nuttig. Vraag over dit model? Stel een vraag

MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD.
2-3, Marunouchi 3-chome, Chiyoda-ku, Tokyo, 100-8332, Japan
https://www.mhi-mth.co.jp/en/
MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, LTD.
5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET, United Kingdom
Tel : +44-333-207-4072
Fax: +44-333-207-4089
https://mhiae.com
MHIAE SERVICES B.V.
(Wholly-owned subsidiary of MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, LTD.)
Herikerbergweg 238, Luna ArenA, 1101 CM Amsterdam, Netherlands
P.O.Box 23393 1100 DW Amsterdam, Netherlands
Tel : +31-20-406-4535
http://www.mhiaeservices.com/
DXKM05Z6-W
DXKM07Z6-W
DXKM09Z6-W
DXKM12Z6-W
ORIGINAL INSTRUCTIONS
MANUAL DEL PROPIETARIO
ACONDICIONADOR DE AIRE
USER’S MANUAL
AIR-CONDITIONER
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO
РЪКОВОДСТВОЗАЕКСПЛОАТАЦИЯ
КЛИМАТИК
ENGLISH
PORTUGUÊS
БЪЛГАРСКИ
ESPAN
˜
OL
USER’S MANUAL
AIR-CONDITIONER
202412
RLC012A116B
ΕΛΛΗΝΙΚΑ
ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ
ΚΛΙΜΑΤΙΣΤΙΚΟ
RLC012A116B_Cover.indd1RLC012A116B_Cover.indd 12024/12/2413:02:162024/12/24 13:02:16

Beoordeel deze handleiding


Foutcodes Mitsubishi DXKM07Z6-W

Foutcodes uit de officiële handleiding, met betekenis en oplossing.

Code Betekenis Oplossing Pagina
1-time flash Indoor of heat exchanger sensor 1 error Broken connection at heat exchanger sensor 1 wire, poor connector connection 25
1-time flash TIMER Outdoor temperature sensor error Broken outdoor sensor wire, poor connector connection
1-time RUN ON Current cut Short circuit, power outage, poor connection or closed service valve
2-time 2-time Rotor lock Open phase on compressor, defective outdoor unit boards
2-time flash Room temperature sensor error Broken room temperature sensor wire, poor connector connection 25
2-time flash TIMER Outdoor heat exchanger sensor error Broken heat exchanger sensor wire, poor connector connection
2-time RUN ON Trouble of outdoor unit Compressor or broken wire, poor connection
3-time flash Indoor of heat exchanger sensor 3 error Broken connection at heat exchanger sensor 3 wire, poor connector connection 25
3-time RUN ON Over current Overload operation, overcharge of refrigerant
4-time flash RUN Discharge pipe sensor error Broken discharge pipe sensor wire, poor connector connection
4-time RUN ON Power transistor error Broken power transistor
5-time flash Circuit error Circuit failure or poor connector connection 25
5-time flash RUN Suction pipe sensor error Broken suction pipe sensor wire, poor connector connection
5-time RUN ON Over heat of compressor Gas shortage, defective discharge pipe sensor, closed service valve
6-time flash Indoor fan motor error Defective fan motor, poor connector connection 25
6-time RUN ON Error of signal transmission Defective indoor/outdoor unit, broken signal wire
7-time 1-time Closed service valve Closed service valve
7-time flash Refrigerant is insufficient Refrigerant is insufficient, leaking, or closed service valve 25
7-time RUN ON Outdoor fan motor error Defective fan motor, poor connector connection
Keep flashing Cooling high pressure protection Overcharge of refrigerant, short circuit of outdoor unit, defective compressor