Bekijk gratis de handleiding van Megger HVDC650 (3 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.7 sterren uit 2 reviews. Heb je een vraag over Megger HVDC650 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/3

In the event of a power outage the automatic discharge
system remains in its current position and no automatic
discharging occurs. In this case however, discharging may
be manually initiated using a rip cord and the gas pressure
spring triggered in the process.
Control Unit with one-button-operation
The device is controlled using the standard Megger one-
button-operation with a quick selection menu as known
from other measurement systems. The display of the pro-
gression over time of current and voltage and the storage
of measurement data takes place on an automated basis
at a frequency of 4 Hz. Reports can be generated via the
Easyprot reporting software and storage of the datasets on
a USB Stick.
To ensure safe operation of the system during an ongoing
DC voltage test or cascade burning, the system automati-
cally shuts down in the event of an overcurrent (manually
adjustable) or overvoltage. This avoids major damage to the
test system and/ or test object in case of malfunctions or
breakdowns.
DESCRIPTION
Megger offers DC test devices for a wide range of voltages
and applications. The HVDC test set is a high-performance,
portable testing system that can be used to evaluate all kind
of high-voltage-direct-current components, in line with the
applicable regulations regarding the generation of HVDC
voltages of up to 800 kV.
The set is predominantly used by power supply companies,
service providers, cable installers and cable manufacturers
for DC testing on high-voltage systems and cables. In
addition, surge arresters, HVDC transformers or insulators
can also be tested and leakage measurements conducted.
The system is suitable for laboratory testing as a permanent-
ly installed installation system, and as a for mobile on-site
applications being stored in a trailer. The modular structure
of the test system facilitates its set-up on site, and allows it
to be adapted to the particular measuring tasks. The high
voltage system is water resistant and features an ammonium
sulphate solution which protects the cascade from surges
caused by breakdowns in the test object.
Apart from DC testing, the short-circuit-proof output circuit
and the system’s high power, enable the HVDC Systems use
during fault location as a burner for modifying high-imped-
ance and intermittent faults.
Each DC voltage test is automatically earthed by the motor-
ised discharge system and thereby set to a safe operational
state. This takes care of secure earthing as well as unearth-
ing before the start of a new measurement. The modular
cascade set for generating high DC voltage is optionally
available with positive polarity.
Test voltages of up to 800 kVDC
DC voltage ripple < 3%
Automatic measuring range switchover
Motorised discharge switch
One-button-operation on 5.7” LCD-colour display
Optionally available in positive polarity
HVDC test systems
Conducting DC voltage tests on all
electric power supply components
Product specificaties
| Merk: | Megger |
| Categorie: | Meetapparatuur |
| Model: | HVDC650 |
Heb je hulp nodig?
Als je hulp nodig hebt met Megger HVDC650 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Megger
24 Juni 2026
24 Juni 2026
23 Juni 2026
3 Juni 2026
2 Juni 2026
2 Juni 2026
1 Juni 2026
11 Augustus 2025
10 Maart 2025
17 November 2024
Handleiding Meetapparatuur
Nieuwste handleidingen voor Meetapparatuur
24 Juni 2026
23 Juni 2026
23 Juni 2026
23 Juni 2026
23 Juni 2026
22 Juni 2026
22 Juni 2026
22 Juni 2026
22 Juni 2026
17 Juni 2026