Megger DPM1000 Handleiding
Megger
Multimeter
DPM1000
Bekijk gratis de handleiding van Megger DPM1000 (42 pagina’s), behorend tot de categorie Multimeter. Deze gids werd als nuttig beoordeeld door 46 mensen en kreeg gemiddeld 4.3 sterren uit 23.5 reviews. Heb je een vraag over Megger DPM1000 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/42

DPM1000
User guide
EN

G Safety Information
Understand and follow the operating instructions carefully.
G WARNING
Identify hazardous conditions and actions that could cause BODILY HARM or DEATH
■ When using test leads or probes, keep your fingers behind the finger guards.
■ Personal protective equipment should be used if there are ACCESSIBLE HAZARDOUS
LIVE PARTS in the installation where measurement is to be carried out.
■ Remove test leads from meter before opening the battery door or meter case.
■ Use the meter only as specified in this manual; otherwise, the protection provided by
the meter may be impaired.
■ Always use the proper input terminals, switch position, and range for measurements.
■ Verify the meters operation by measuring a known voltage. If in doubt, have the meter
calibrated.
■ Do not apply more than the rated voltage, as marked on the meter, between terminals
or between any terminal and earth.
■ Use caution with voltages above 30 V AC rms, 42 V AC peak, or 60 V DC. These voltages
pose a shock hazard.
■ To avoid false readings that can lead to electric shock and injury, replace the battery as
soon as the low battery indicator blinks.
■ Disconnect circuit power and discharge all high-voltage capacitors before testing
resistance, continuity, diodes, or capacitance.
■ Do not use the meter around explosive gas or vapour.
■ To reduce the risk of fire or electric shock do not expose this product to rain or moisture.
■ Probe assemblies to be used for MAINS measurements shall be RATED as appropriate
for MEASUREMENT CATEGORY III or IV according to EN 61010-031 and shall have a
voltage RATING of at least the voltage of the circuit to be measured.
■ DO NOT USE the test leads if the internal white insulation layer is exposed.
■ DO NOT USE the test leads above maximum ratings of CAT Environment or voltage and
current that are indicated on the probe and probe tip guard.
■ Do not apply a current with a frequency that is higher than the frequency response
range specified in the Electrical Specifications section.
■ Do not apply or remove the clamp or test leads on or around uninsulated hazardous live
conductors where a potential to cause electric shock, electrical burns or arc flash exists.
User Guide www.megger.com
2
Product specificaties
Merk: | Megger |
Categorie: | Multimeter |
Model: | DPM1000 |
Heb je hulp nodig?
Als je hulp nodig hebt met Megger DPM1000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Multimeter Megger
7 December 2024
17 November 2024
17 November 2024
8 Juni 2024
3 Juli 2023
2 Juli 2023
1 Juli 2023
22 Juni 2023
Handleiding Multimeter
- Sauermann
- Milwaukee
- Rigol
- Testo
- Velleman
- Qian
- Elworks
- Benning
- Uni-T
- Extech
- Digi-tool
- Bosch
- Bearware
- Monacor
- Micronta
Nieuwste handleidingen voor Multimeter
8 September 2025
8 September 2025
8 September 2025
1 September 2025
1 September 2025
30 Augustus 2025
25 Augustus 2025
25 Augustus 2025
14 Augustus 2025
14 Augustus 2025