Bekijk gratis de handleiding van Mean Well WDR-240-24 (7 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 369 mensen en kreeg gemiddeld 4.5 sterren uit 185 reviews. Heb je een vraag over Mean Well WDR-240-24 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/7

Test Report: WDR-240-24
240W Single Output Industrial DIN RAIL Power Supply
DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
Control Function Test
Component Stress Test
SAFETY & E.M.C. TEST
Safety Test
E.M.C. Test
RELIABILITY TEST
ENVIRONMENT TEST

WDR-240series
Model: WDR-240-24 Test Report 2 / 7
DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 RIPPLE & NOISE V1:150
mVp-p (Max )
I/P: 400VAC
O/P:FULL LOAD
Ta:25℃
V1:
50
mVp-p (Max )
P
2 OUTPUT VOLTAGE
ADJUST RANGE
CH1: 24 V ~ 28 V I/P: 400 VAC
I/P: 230 VAC
O/P:MIN LOAD
Ta:25℃
23.501
23.496
V ~
V ~
28.739
28.734
V/ 400 VAC
V/ 230 VAC P
3 OUTPUT VOLTAGE
TOLERANCE
V1: 1 %~ -1 % (Max) I/P:200 VAC / 550 VAC
O/P:FULL/ MIN LOAD
Ta:25℃
V1:
0.2 %~
-0.2 %
P
4 LINE REGULATION V1: 0.5%~ -0.5 % (Max)
I/P:200 VAC ~ 550 VAC
O/P:FULL LOAD
Ta:25℃
V1:
0.03 %~
-0.03 %
P
5 LOAD REGULATION V1: 1 %~ -1 % (Max)
I/P: 400 VAC
O/P:FULL ~MIN LOAD
Ta:25℃
V1:
0.2 %~
-0.2 %
P
6 SET UP TIME 400VAC: 1500 ms (Max) I/P: 400 VAC
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
400VAC/ 434 ms
P
230VAC: 3000 ms(Max) 230VAC/ 810 ms
7 RISE TIME 400VAC: 150 ms (Max) I/P: 400 VAC
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
400VAC/ 44 ms
P
230VAC: 150 ms (Max) 230VAC/ 57 ms
8 HOLD UP TIME 400VAC: 16 ms (TYP) I/P: 400 VAC
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
400VAC/ 22 ms
P
230VAC: 14 ms (TYP) 230VAC/ 20 ms
9 OVER/UNDERSHOOT
TEST
< +5% I/P: 400 VAC
O/P:FULL LOAD
Ta:25℃
TEST: < 5 %
P
10 DYNAMIC LOAD V1: 2400 mVp-p I/P: 400 VAC
(1).O/P:FULL /Min LOAD 90%DUTY/
1KHZ
(2).O/P:FULL /Min LOAD 50%DUTY/
120HZ
Ta:25℃
(1). 293
(2) 903
mVp-p
mVp-p
P

WDR-240series
Model: WDR-240-24 Test Report 3 / 7
INPUT FUNCTION TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 INPUT VOLTAGE RANGE 180VAC~550 VAC I/P:TESTING
O/P:FULL LOAD
Ta:25℃
160 V~550V
P
I/P:
LOW-LINE-3V= 177 V
HIGH-LINE+10V=560 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
( AC POWER ON/OFF NO DAMAGE )
TEST: OK
2 INPUT FREQUENCY
RANGE
47HZ ~63 HZ
NO DAMAGE OSC
I/P:180 VAC ~ 550 VAC
O/P:FULL~MIN LOAD
Ta:25℃
TEST: OK
P
3 EFFICIENCY 91 % (TYP) I/P: 400 VAC
O/P:FULL LOAD
Ta:25℃
91.46 %
P
4 INPUT CURRENT 400V/ 1 A (TYP) I/P: 400 VAC
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
I = 0.76 A/ 400 VAC
P
230V/ 2 A (TYP) I = 1.30 A/ 230 VAC
5 INRUSH CURRENT 400V/ 50 A (TYP) I/P: 400 VAC
O/P:FULL LOAD
Ta:25℃
I = 46 A/ 400 VAC
P
COLD START
6 LEAKAGE CURRENT < 3.5 mA / 530 VAC I/P: 530 VAC
O/P:Min LOAD
Ta:25℃
L-FG: 1.1 mA
P
N-FG: 1.1 mA
7 POWER FACTOR 0.84 / 400VAC(TYP)
0.84 /230 VAC(TYP)
I/P: 400 VAC
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
PF= 0.857 / 400VAC
PF= 0.859 / 230 VAC P
PROTECTION FUNCTION TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 OVER LOAD PROTECTION 105 % ~ 130 % I/P: 400 VAC
I/P: 230 VAC
O/P:TESTING
Ta:25℃
125.7 %/ 400 VAC
125.7 %/ 230 VAC
Constant current limiting, unit
will shut down after 3 sec. ,
auto-recovery after 1 minute if
the fault condition is removed
P
2 OVER VOLTAGE PROTECTION CH1: 29~ 33 V I/P: 400 VAC
I/P: 230 VAC
O/P:MIN LOAD
Ta:25℃
30.50 V/ 400 VAC
30.71 V/ 230 VAC
Shut down o/p voltage,auto
recovery after 1minute if the fault
condition is removed.
P
3 OVER TEMPERATURE PROTECTION SPEC:
TSW1: 90 + 5℃ O.T.P.
NO DAMAGE
I/P: 400 VAC
O/P:FULL LOAD
O.T.P. Active
Shut down o/p voltage,recovers
automatically after temperature
goes down
P
4 SHORT PROTECTION SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
I/P: 550 VAC
O/P:FULL LOAD
Ta:25℃
NO DAMAGE
Constant current limiting, unit
will shut down after 3 sec. ,
P
Product specificaties
Merk: | Mean Well |
Categorie: | Niet gecategoriseerd |
Model: | WDR-240-24 |
Kleur van het product: | Metallic |
Gewicht: | 1060 g |
Breedte: | 63 mm |
Diepte: | 113.5 mm |
Hoogte: | 125.2 mm |
Geluidsniveau: | - dB |
Temperatuur bij opslag: | -40 - 85 °C |
Stroomspanning bescherming: | Over voltage, Overheating, Overload, Short circuit |
Luchtvochtigheid bij opslag: | 10 - 95 procent |
Mean time between failures (MTBF): | 141100 uur |
Totaal vermogen: | 240 W |
Type koeling: | Passief |
Efficientie: | 91 procent |
AC-ingangsspanning: | 180 - 550 V |
AC-ingangsfrequentie: | 47 - 63 Hz |
Bedrijfstemperatuur (T-T): | -30 - 70 °C |
Relatieve vochtigheid in bedrijf (V-V): | 20 - 95 procent |
Ventilator diameter: | - mm |
Houd-tijd: | 18 ms |
Toename-tijd: | 150 ms |
Heb je hulp nodig?
Als je hulp nodig hebt met Mean Well WDR-240-24 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Mean Well
3 Januari 2025
3 Januari 2025
11 December 2024
17 November 2024
1 November 2024
9 Juli 2024
4 Mei 2024
15 Augustus 2023
9 Juli 2023
9 Juli 2023
Handleiding Niet gecategoriseerd
- Valueline
- Rug Doctor
- Beper
- Kelty
- Trijicon
- Monogram
- Acard
- Wacker Neuson
- Sonoff
- AvMap
- AvaValley
- IMAC
- Pyle Pro
- Baby Lock
- Tablo
Nieuwste handleidingen voor Niet gecategoriseerd
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025