Bekijk gratis de handleiding van Mean Well WDR-120-24 (7 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 52 mensen en kreeg gemiddeld 4.0 sterren uit 26.5 reviews. Heb je een vraag over Mean Well WDR-120-24 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/7
Test Report: WDR-120-24
120W Single O utput Switching Power Supply
DESIGN VERIFY TEST
O F Tutput unction est
Input Function Test
Protection Function Test
C F Tontrol unction est
Component Stress Test
SAFETY & . E.M.C TEST
Safety Test
E.M.C. Test
RELIABILITY TEST
ENVIRONMENT TEST
WDR 120- series
Model: WDR- -120 24 Test Report 2 7 /
DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
SPECIFICATION
TEST CONDITION
RESULT
VERDICT
1 RIPPLE & NOISE
V1
120
mVp-p (Max )
I/P
400VAC
O/PFULL LOAD
Ta 25
V1
74.8
mVp-p (Max )
P
2 OUTPUT VOLTAGE
ADJUST RANGE
CH1
V 24 ~ 29 V
I/P
400 VAC
I/P 230 VAC
O/PMIN LOAD
Ta25
23.21
23.21
V ~
V ~
30.68
30.68
V/ 400 VAC
V/ 230 VAC P
3 OUTPUT VOLTAGE
TOLERANCE
V1
1 1 %~ % (Max)
I/P
200 VAC / 550 VAC
O/PFULL/ MIN LOAD
Ta25
V1
0.05
%~
- 0.05
%
P
4 LINE REGULATION
V1
0.5 %~ 0.5 % (Max)
I/P
200 VAC ~ 550 VAC
O/PFULL LOAD
Ta25
V1
0
%~
0
%
P
5 LOAD REGULATION
V1
0.5 %~ 0.5 % (Max)
I/P
400 VAC
O/PFULL ~MIN LOAD
Ta25
V1
0.05
%~
- 0.05
%
P
6 SET UP TIME
400VAC
2000
ms (Max)
I/P
400 VAC
I/P 230 VAC
O/PFULL LOAD
Ta
25
400VAC/
378
ms
P
230VAC 2000 ms(Max) 230VAC/ 417 ms
7 RISE TIME
400VAC
70
ms (Max)
I/P 400 VAC
I/P 230 VAC
O/PFULL LOAD
Ta25
400VAC/
51
ms
P
230VAC
70 ms (Max) 230VAC/ 50 ms
8 HOLD UP TIME
400VAC
50
ms (TYP)
I/P
400 VAC
I/P 230 VAC
O/PFULL LOAD
Ta25
400VAC/
61
ms
P
230VAC 10 ms (TYP) 230VAC/ 13.8 ms
9 OVER/UNDERSHOOT
TEST
< + 5% I/P 400 VAC
O/PFULL LOAD
Ta
25
TEST < 5 %
P
10 DYNAMIC LOAD
V1
2400 -p mVp
I/P
400 VAC
O/PFULL /Min LOAD 90%DUTY/
1KHZ
Ta25
261 -p mVp
P
WDR 120- series
Model: WDR- -120 24 Test Report 3 7 /
INPUT FUNCTION TEST
NO
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
VERDICT
1 INPUT VOLTAGE RANGE 200VAC ~ 550 VAC I/PTESTING
O/PFULL LOAD
Ta25
146V~550V
P
I/P
- - V LOW LINE 3V= 197
-HIGH LINE+10V= V 560
O/PFULL/MIN LOAD
ON30 Sec . OFF30 Sec 10MIN
( AC POWER ON/OFF NO DAMAGE )
TEST OK
2 INPUT FREQUENCY
RANGE
47HZ ~63 HZ
NO DAMAGE
I/P
200 550 VAC ~ VAC
O/PFULL~MIN LOAD
Ta25
TEST
OK
P
3 EFFICIENCY 91 % (TYP) I/P 400 VAC
O/PFULL LOAD
Ta
25
91.16 %
P
4 INPUT CURRENT
400V/
0.7
A (TYP)
I/P
400 VAC
I/P 230 VAC
O/PFULL LOAD
Ta25
I =
0.693
A/ 400 VAC
P
230 99 230V/ ( 1.2 A TYP) I = 0. A/ VAC
5 INRUSH CURRENT 400V/ 50 A (TYP) I/P 400 VAC
O/PFULL LOAD
Ta25
I = 4 2.6 A/ 400 VAC
P
COLD START
6 LEAKAGE CURRENT < 3.5 mA / 530 VAC I/P 5 30 VAC
O/PMin LOAD
Ta25
L-FG
1.35
mA
P
N-FG
1 .35 mA
PROTECTION FUNCTION TEST
NO
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
VERDICT
1 OVER LOAD PROTECTION % 105 ~ 130 %
I/P
400 VAC
I/P 230 VAC
O/PTESTING
Ta25
120%/ 400 VAC
120%/ 230 VAC
Constant Current Limiting
P
2 OVER VOLTAGE PROTECTION CH1: : V V 31 ~ 37 I/P 400 VAC
I/P 230 VAC
O/PMIN LOAD
Ta25
33.76 V/ 400 VAC
34.1 V/ 230 VAC
Shut down Re- power ON
P
3 OVER TEMPERATURE PROTECTION SPEC
+ 5 TSW1105 O.T.P.
NO DAMAGE
I/P 400 VAC
O/PFULL LOAD
O.T.P. Active
Shut down o/p voltagerecovers
automatically after temperature
goes down
P
4 SHORT PROTECTION SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
I/P
550 VAC
O/PFULL LOAD
Ta25
NO DAMAGE
Constant Current Limiting
P
CONTROL FUNCTION TEST
NO
T EST ITEM
SPECIFICATION
TEST CONDITION
RESULT
VERDICT
1 DC OK SIGNAL
Relay contact rating(max.) :
30V / 1A resistive
I/P: 400 VAC
O/P:FULL LOAD
OK
P
COMPONENT STRESS TEST


Product specificaties

Merk: Mean Well
Categorie: Niet gecategoriseerd
Model: WDR-120-24
Kleur van het product: Metallic
Breedte: 40 mm
Diepte: 113.5 mm
Hoogte: 125.2 mm
Geluidsniveau: - dB
Stroom: 0.7 - 1.2 A
Temperatuur bij opslag: -40 - 85 °C
Stroomspanning bescherming: Over voltage, Overheating, Overload, Short circuit
Luchtvochtigheid bij opslag: 10 - 95 procent
Mean time between failures (MTBF): 268000 uur
Totaal vermogen: 120 W
Type koeling: Passief
Efficientie: 91 procent
AC-ingangsspanning: 180 - 550 V
AC-ingangsfrequentie: 47 - 63 Hz
Bedrijfstemperatuur (T-T): -25 - 70 °C
Relatieve vochtigheid in bedrijf (V-V): 20 - 95 procent
Ventilator diameter: - mm
Houd-tijd: 50 ms
Voltage tolerantie: 1.5 procent
Toename-tijd: 70 ms

Heb je hulp nodig?

Als je hulp nodig hebt met Mean Well WDR-120-24 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden