Mean Well LPV-35-12 Handleiding


Pagina's 5 Engels Niet gecategoriseerd

Bekijk de handleiding van Mean Well LPV-35-12 gratis online of download de PDF. Deze handleiding is 15 keer bekeken. Vraag over dit model? Stel een vraag

35W Single Output Switching Power Supply LPV-35 series
Model: LPV-35-12 Test Report 1 / 5
MODEL:
:
:
::LPV-35-12
OUTPUT FUNCTION TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 RIPPLE & NOISE V1:120
mVp-p (Max )
I/P: 230VAC
O/P:FULL LOAD
Ta:25℃
V1:
20.4
mVp-p (Max )
P
2 OUTPUT VOLTAGE
TOLERANCE
V1:5 %~ -5 % (Max)
I/P: 100VAC / 264 VAC
O/P:FULL/ MIN LOAD
Ta:25℃
V1:
0.6 %~
-0.6 %
P
3 LINE REGULATION V1: 1 %~ -1 % (Max)
I/P: 100 VAC ~ 264 VAC
O/P:FULL LOAD
Ta:25℃
V1:
0.1 %~
-0.1 %
P
4 LOAD REGULATION V1: 2%~ -2% (Max)
I/P: 230 VAC
O/P:FULL ~MIN LOAD
Ta:25℃
V1:
0.6 %~
-0.6 %
P
5 SET UP TIME
230VAC:
500 ms (Max) I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/ 158 ms
P
115 VAC:
500 ms (Max) 115VAC/ 123 ms
6 RISE TIME 230VAC:
20 ms (Max) I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/ 11 ms
P
115VAC: 115VAC/ 20 ms (Max) 10 ms
7 HOLD UP TIME 230VAC:
50 ms (TYP)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/ 118 ms
P
115VAC: 16 ms (TYP)
115VAC/ 25 ms
8 OVER/UNDERSHOOT TEST < +5%I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
TEST: <5 %
P
9 DYNAMIC LOAD V1: 1200 mVp-p I/P: 230 VAC
O/P:FULL /Min LOAD
90%DUTY/1KHZ
Ta:25℃
172 mVp-p
P

Beoordeel deze handleiding


Product specificaties

Merk: Mean Well
Categorie: Niet gecategoriseerd
Model: LPV-35-12
Kleur van het product: Wit
Breedte: 148 mm
Diepte: 40 mm
Hoogte: 30 mm
Stroom: 3 A
Totaal vermogen: 35 W
AC-ingangsspanning: 100 - 264 V
AC-ingangsfrequentie: 47 - 63 Hz
Voltage tolerantie: 5 procent
Frequentie tolerantie: 85 procent

Heb je hulp nodig?

Als je hulp nodig hebt met Mean Well LPV-35-12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden