Pagina 1/46
3.6KW/5.6KW
SOLAR INVERTER GER/ CHAR
Version: 1.0
User Manual
Table Contents of
ABOUT THIS MANUAL ...................................................................................................................................... 1
Purpose ............................................................................................................................................................ 1
Scope ............................................................................................................................................................... 1
SAFETY INSTRUCTIONS ................................................................................................................................... 1
INTRODUCTION ................................................................................................................................................. 2
Features ........................................................................................................................................................... 2
Basic System Architecture ............................................................................................................................... 2
Product Overview ............................................................................................................................................. 3
Unpacking and Inspection ............................................................................................................................... 4
Preparation ...................................................................................................................................................... 4
Mounting the Unit ............................................................................................................................................. 4
Battery Connection .......................................................................................................................................... 5
AC Input/Output Connection ............................................................................................................................ 6
PV Connection ................................................................................................................................................. 7
Final Assembly ................................................................................................................................................. 9
Communication Connection ............................................................................................................................. 9
Dry Contact Signal ......................................................................................................................................... 10
OPERATION ...................................................................................................................................................... 11
Power ON/OFF .............................................................................................................................................. 11
Operation and Display Panel ......................................................................................................................... 11
LCD Display Icons ......................................................................................................................................... 12
LCD Setting .................................................................................................................................................... 15
LCD Display ................................................................................................................................................... 31
Operating Mode Description .......................................................................................................................... 37
Faults Reference Code .................................................................................................................................. 40
Warning Indicator ........................................................................................................................................... 41
BATTERY EQUALIZATION .............................................................................................................................. 42
SPECIFICATIONS ............................................................................................................................................. 43
Table 1 Line Mode Specifications ................................................................................................................... 43
Table 2 Invert Mode Specificationser ............................................................................................................. 44
Table 3 Charge Mode Specifications ............................................................................................................... 45
Table 4 General Specifications ........................................................................................................................ 45
TROUBLE SHOOTING ..................................................................................................................................... 46
Appendix I: Parallel function .......................................................................................................................... 47
Appendix II: BMS Communication Installation ............................................................................................. 64
Appendix III: The Wi-Fi Operation Guide ....................................................................................................... 72
1
ABOUT THIS MANUAL
Purpose
This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read
this manual carefully before installations and operations. Keep this manual for future reference.
Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
SAFETY INSTRUCTIONS
WARNING: This chapter contains important safety and operating instructions. Read and keep
this manual for future reference.
1. Before using the unit, read all instructions and cautionary markings on t unit, the batteries and all he
appropriate sections of this manual.
2. CAUTION – To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries.
Other types of batteries may burst, causing personal injury and damage.
3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required.
Incorrect re-assembly may result in a risk of electric shock or fire.
4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning.
Turning off the unit will not reduce this risk.
5. CAUTION – Only qualified personnel can install this device with battery.
6. NEVER charge a frozen battery.
7. For optimum operation of this inverter/charger, please follow required spec to select appropriate cable
size. It’s very important to correctly operate this inverter/charger.
8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop
a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please
refer to INSTALLATION section of this manual for the details.
10. Fuses are provided as over-current protection for the battery supply.
11. GROUNDING INSTRUCTIONS -This inverter/charger should be connected to a permanent grounded
wiring system. Be sure to comply with local requirements and regulation to install this inverter.
12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input
short circuits.
13. Warning !! Only qualified service persons are able to service this device. If errors still persist after
following troubleshooting table, please send this inverter/charger back to local dealer or service
center for maintenance.
14. WARNING: Because this inverter is non-isolated, only three types of PV modules are acceptable:
single crystalline, poly crystalline with class A-rated and CIGS modules. To avoid any malfunction, do
not connect any PV modules with possible current leakage to the inverter. For example, grounded PV
modules will cause current leakage to the inverter. When using CIGS modules, please be sure NO
grounding.
15. CAUTION: It’s required to use PV junction box with surge protection. Otherwise, it will cause
damage on inverter when lightning occurs on PV modules.


Product specificaties