Bekijk gratis de handleiding van M-Locks EM2010 DX (4 pagina’s), behorend tot de categorie Kluis. Deze gids werd als nuttig beoordeeld door 62 mensen en kreeg gemiddeld 3.5 sterren uit 31.5 reviews. Heb je een vraag over M-Locks EM2010 DX of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/4

DirectXion
M-LOCKS BV Tel: +31 (0)314 376 876
Vlijtstraat 40 ver. 1.2 2010 10 28 Fax: +31 (0)314 376 878
NL-7005 BN Doetinchem 1 of 2 www.m-locks.com
Technical manual
Mounting instructions
EM2010 DX
CHARACTERISTICS
The DirectXion lock can be mounted in all four mounting directions. Also, by flipping the lock,
all blocking directions can be achieved. The mounting dimensions are standard. The lock is
delivered with metric (M6) mounting screws. The PCB board in this lock is intended as an
OEM solution for customers who would like to control the lock via their own electronics. Once
voltage is supplied the lock will open for a 5 seconds and the boltwork can be moved into
OPEN position by pushing the bolt inside the lock case. After 5 seconds the board will cut
power to blocking element regardless if voltage is still supplied from external system. When
moving the boltwork into LOCKED position the DirectXion automatically locks. To open the
lock again the voltage has to be dropped and re-applied.
BOLTWORK REQUIREMENTS and MOUNTING INSTRUCTIONS
The maximum allowed cable/spindle-hole diameter is 12mm (if located under the lock body)
If the DirectXion lock is used in conjunction with another lock, the boltwork must be
constructed in a way that the DirectXion secures first.
In the LOCKED position the distance between the
DirectXion bolt and the boltwork part that is
moving the lock bolt should be approximately 1
mm.
Only use supplied screws to mount the lock.
Tighten the screws securely so the lock body is
attached firmly to the mounting surface.

DirectXion
M-LOCKS BV Tel: +31 (0)314 376 876
Vlijtstraat 40 ver. 1.2 2010 10 28 Fax: +31 (0)314 376 878
NL-7005 BN Doetinchem 2 of 2 www.m-locks.com
Connection to lock is via a RJ45 (female) connector on lock case. Cable (Art.nr. 390) has to
be ordered separately. Min voltage: 9V, Maximum voltage: 12V.

DirectXion
M-LOCKS BV Tel: +31 (0)314 376 876
Vlijtstraat 40 ver. 1.2 2010 10 28 Fax: +31 (0)314 376 878
NL-7005 BN Doetinchem 1 of 2 www.m-locks.com
Technical manual
Mounting instructions
EM3510 DX
CHARACTERISTICS
The DirectXion lock can be mounted in all four mounting directions. Also, by flipping the lock,
all blocking directions can be achieved. The mounting dimensions are standard. The lock is
delivered with metric (M6) mounting screws. The PCB board in this lock is intended as an
OEM solution for customers who would like to control the lock via their own electronics. Once
voltage is supplied the lock will open for a 5 seconds. The lock can be opened. After 5
seconds the board will cut power to blocking element regardless if voltage is still supplied
from external system. To open the lock again after closure the voltage has to be dropped and
re-applied.
BOLTWORK REQUIREMENTS and MOUNTING INSTRUCTIONS
The maximum allowed cable/spindle-hole diameter is 12mm (if located under the lock body)
If the DirectXion lock is used in conjunction with another lock, the boltwork must be
constructed in a way that the DirectXion secures first.
Only use supplied screws to mount the lock. Tighten the screws securely so the lock body is
attached firmly to the mounting surface.
Product specificaties
Merk: | M-Locks |
Categorie: | Kluis |
Model: | EM2010 DX |
Heb je hulp nodig?
Als je hulp nodig hebt met M-Locks EM2010 DX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Kluis M-Locks
26 September 2023
26 September 2023
26 September 2023
26 September 2023
26 September 2023
26 September 2023
26 September 2023
26 September 2023
26 September 2023
26 September 2023
Handleiding Kluis
- Winholt
- Stamony
- Philips
- Duralock
- Topcraft
- Royal Safe
- Rottner
- Oxloc
- First Austria
- Sentry
- Suncast
- Varo
- Homak Security
- Conrad
- Burg Wächter
Nieuwste handleidingen voor Kluis
14 Juni 2025
14 Juni 2025
3 Juni 2025
30 Mei 2025
22 Mei 2025
22 Mei 2025
22 Mei 2025
21 Mei 2025
21 Mei 2025
15 April 2025