Bekijk gratis de handleiding van Lowell SEQ-8 (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 22 mensen en kreeg gemiddeld 4.1 sterren uit 7 reviews. Heb je een vraag over Lowell SEQ-8 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1603
Model SEQ-8 Rev. 08-12-21 | pg. 1/4
INTERNAL USE ONLY: PN 24369
Compact low voltage eight step sequencer model SEQ-8 is
designed to work with single or multiple external switches and
low voltage remote power controls (RPCs) to provide time-
delayed activation and deactivation of AC powered equipment
Note: This sequencer is for use with compatible components that feature classic
connections. It is not for use with devices that feature pass-through connections.
FEATURES:
Power Requirement: 100-240VAC 12W
Activation Trigger: Sequencing is initiated by a remote
external SPST switch or switches (order separately). Slide the
bar to select single or multiple switch mode.
For Single Switch Applications: Use an SPST switch with
MAINTAINED contact closure.
For Multiple Switch Applications: Use SPST switches with
MOMENTARY contact closure.
Eight (8) Step Delay:
Eight time-delayed closure circuits activate in sequential
order (1, 2, 3, 4, 5, 6, 7, 8) and deactivate in reverse order.
The delay between steps can be adjusted via an externally
accessible trimpot (0.5-10 seconds).
LEDs provide visual status of the sequence.
Includes auxiliary 24VDC output (300mA max.) for use with
remote indicators.
Compact Chassis:10" x 3.28" x 1.69" steel chassis with
black powder epoxy finish and mounting holes.
Unit can be installed in a remote location or rack panel (2U).
Operational diagram printed on top of chassis aids system
set-up.
Country of Origin: Made in U.S.A. with global components
Power Supply:UL Listed power supply (100-240VAC input,
24VDC 500mA output) with 6 ft. cord and NEMA 1-15P plug.
Includes three adaptors for international use (Schuko CEE
7/16, BS1362, AS3112).
Installation: The sequencer is typically installed in a
convenient location, while remote power controls are placed
near equipment to be controlled—in another rack, room or
building.
Maximum distance between sequencer and remote power
controls: 22 gauge wire = 6,600 ft.; 18 gauge wire =
17,160 ft.
Maximum distance between sequencer and switch:
22 gauge wire = 100 ft.; 18 gauge wire = 200 ft.
System Capacity: Accepts up to 10 RPCs per step.
Connections:Order compatible remote power controls and
switches separately. (See last page.)
A&E Specications:The power sequencer shall be Lowell
model SEQ-8, which shall feature barrier strip terminals for
connection to a single external SPST switch with maintained
contact closure or multiple external SPST switches with
momentary closure. The sequencer shall connect to remote
power controls (RPCs) to activate equipment in up to eight
steps with an adjustable time delay between each step. It shall
activate the RPCs in sequential order and deactivate them in
reverse order. The sequencer shall feature a steel chassis
with mounting holes, black powder epoxy finish, and overall
dimensions of 10" x 3.28" x 1.69". shall be made in the It
USA with global components, and include a UL Listed power
supply with NEMA 1-15P plug and three adaptors (Schuko
CEE 7/16, BS1362, AS3112). External switch(es) and remote
power controls are required for sequencer use and shall be
ordered separately.
Low Voltage Sequencer (8 step): SEQ-8
Made in USA
INPUT for activation trigger (select single or multiple switches)
Chart for connections
Screwdriver-adjustable delay setting
Includes power supply
with NEMA 1-15P plug
and three adaptors
OUTPUT to connections
(up to 10 RPCs per circuit)
LEDs show sequencing status

Beoordeel deze handleiding

4.1/5 (7 Beoordelingen)

Product specificaties

Merk: Lowell
Categorie: Niet gecategoriseerd
Model: SEQ-8

Heb je hulp nodig?

Als je hulp nodig hebt met Lowell SEQ-8 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Lowell

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Ruvati
Fluidmaster
Waterstone
Haws

Haws AX13S Handleiding

11 Februari 2026
Dals

Dals LWJ24-CC Handleiding

11 Februari 2026
Maax

Maax 420005 Handleiding

11 Februari 2026
Kohler

Kohler K-7261 Handleiding

11 Februari 2026