TIMER LIGHT STATUS OPTION CARD
The TLS1CARD has different configuration modes that determine how the TLS1CARD will function.
MODE COMPARABLE MODIFICATION DESCRIPTION
90-T1, 90-515774, or RDGRNCARD • 3 relay outputs (R1, R2, and R3) with optional flashing for R1TCP Mode 1
• Adjustable Pre-Warning
• R1 output on during Pre-Warning, while in motion, and at an
undefined stopped position
• R2 output on at fully open and at open mid-stop
• R3 output on while closing only
90-T2 • 3 relay outputs (R1, R2, and R3)TCP Mode 2
• Adjustable Pre-Warning
• R1 output on during Pre-Warning only
• R2 output on at fully open
• R3 output on only when a special input to open has been used to
open the door which does not activate the Timer-to-Close
TCP Mode 3 90-T4 • 3 relay outputs (R1, R2, and R3)
• Adjustable Pre-Warning
• R1 output on during Pre-Warning only
• R2 output on at fully open and at open mid-stop
• R3 output on while in motion
90-RGLFCIR or 90-HDFLASH2 • TCP Mode 4 2 relay outputs (R1, R2) with optional flashing for R1
• Adjustable Pre-Warning
• R1 output on during Pre-Warning and while closing
• R2 output on at fully open
90-T3 • 3 relay outputs (R1, R2, and R3)TCP Mode 5
• Adjustable Pre-Warning
• R1 output on at all times except fully open and fully closed
• R2 output on at fully open
• R3 output on only when a special input to open has been used to
open the door which does not activate the Timer-to-Close
90-L3FLASH • 3 relay outputs (R1, R2, and R3) with optional flashing for R1TC Mode 1
• R1 output on while in motion
• R2 output on at fully open and at open mid-stop
• R3 output on at fully open, open mid-stop, and at an undefined
stopped position
90-42104 This mode allows a second set of external, track mounted limits to act SP Mode 1
as primary or backup for the operator’s open, close, and safety limits.
NOTE: It is not required that all three inputs have a switch connected to
the TLS1CARD. Either the external close, external safety, external open,
or all three may be used.
2
TIMER FUNCTIONS
Timer-to-Close (TTC): The TTC is an adjustable setting that can be set to automatically close the
door after a specified period of time (Figure 1).
Timer-to-Close (TTC) with Pre-Warning: The TTC is an adjustable setting that can be set to
automatically close the door after a specified period of time. Pre-Warning is a separate adjustable
setting that will activate an auxiliary device for a specified period of time before the door starts to
close (Figure 2).
INTRODUCTION
TTC
starts
FIGURE 1: TIMER-TO-CLOSE (TTC)
Door starts
to close
EXAMPLE: TTC set
to 45 seconds.
FIGURE 2: TIMER-TO-CLOSE (TTC)
WITH PRE-WARNING
EXAMPLE: TTC set
to 45 seconds and
Pre-Warning set
to 15 seconds.
TTC
starts
Pre-Warning starts
Stage 1
Stage 2
Door starts
to close
WARNINGS
To prevent possible SERIOUS INJURY or DEATH from
electrocution, disconnect electric power to operator BEFORE
installing.
ALL electrical connections MUST be made by a qualified
individual.
WARNING
WARNING
WARNING
WARNING
WARNING
To prevent possible PROPERTY DAMAGE, ACCIDENTAL
ENTRAPMENT, SEVERE INJURY, or DEATH:
• Disconnect power to the operator and fully open or close the
door BEFORE installing ANY entrapment protection devices.
• LiftMaster Monitored Entrapment Protection (LMEP) devices
MUST be installed for all wiring types except constant
pressure to close. However, LiftMaster Monitored Entrapment
Protection (LMEP) devices are recommended for constant
pressure to close.
• LiftMaster Monitored Entrapment Protection (LMEP) devices
MUST be installed when a radio is used.
• LiftMaster Commercial Door Operators require that ONLY
LiftMaster Monitored Entrapment Protection (LMEP) devices
be installed. Installing devices other than LiftMaster Monitored
Entrapment Protection (LMEP) devices will void the warranty.
WARNING
WARNING
WARNING
WARNING
WARNING
APPLICATION
For use with Logic 4 Industrial Duty and Heavy Industrial Duty Operators.
When installed in a Logic 4 (L4) operator, the Timer Light Status Option Card (TLS1CARD) provides special functionality to control
auxiliary devices such as lights, bells, horns, horn/strobes, etc. at various door positions. The TLS1CARD also provides special timer
functions that are described in more detail on the following pages.
NOTE: Only one TLS1CARD can be used within the Logic 4 operator however it can be used in conjunction with other option cards such
as the AUXCARD, FDRCARD, or CPS3.
3
Disconnect power to the operator.
Turn all the DIP switches on the TLS1CARD to the OFF position.
Connect the auxiliary device(s) to the input and output terminals on the TLS1CARD as described below.
After configurations and connections have been made for your card mode proceed to Installation page 10.
TCP MODE 1
TCP (TRAFFIC CONTROL MODE WITH PRE-WARNING) MODE 1
This mode is intended to control auxiliary devices connected to relays R1, R2, and R3 with optional flashing for relay R1. It also
incorporates an adjustable Timer-to-Close (TTC) plus a separately adjustable Pre-Warning. The relays can be used with or without the
timers programmed. This mode has similar functionality to the RDGRNCARD used with Logic 3 operators. This mode would be used in
lieu of previous modification 90-T1, 90-515774, or RDGRNCARD functionality (light box not included).
Fully Open
(OLS)
Timer Stage 1
(OLS & OMS
Only)
Timer Stage 2
(Pre-Warning)
(OLS & OMS
Only)
Closing Fully Closed
(CLS)
Opening Undefined
Stopped
Position (USP)
Open Mid-Stop
(OMS)
Reversing from
Obstruction
R1 LED
R2 LED
R3 LED
OFF
ON
OFF
OFF
ON
OFF
ON or Flash
OFF
OFF
ON or Flash
OFF
ON
OFF
OFF
OFF
ON or Flash
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON or Flash
OFF
OFF
NOTES:
• Relay LEDs R1, R2, and R3 on the TLS1CARD will turn ON at the same time as relays R1, R2, and R3.
• During timer stages 1 and 2 the relays shown are only ON/OFF when the door is positioned as shown in parenthesis. The selector
dial on the operator would be set to T, TS, or FSTS.
1 2 3 4
O
N
TCP MODE 1 DIP SWITCH SETTINGS
TLS1CARD
40-35757-1
Timer Light Status Option Card
R3
R2
R1
6
5
4
3
2
1
T/TS 12
FD/SIS 11
COMMON 10
SIC 9
SIO 8
COMMON 7
(RELAYS)
OUTPUTS
INPUTS
5 A, 230 Vac, 30 Vdc Dry Contact Only
N.O.
Comm
N.O.
Comm
N.O.
Comm
Horn/Strobe
Green
Red
2-Position
Maintained Switch
TCP MODE 1 (TYPICAL CONNECTION)
1
2
3
Outputs:
• Connect a red light to the R1 terminals on the TLS1CARD. This will signal when the door is at any position other than the fully
open, fully closed or at a programmed mid-stop. With a timer enabled, this relay is also the Pre-Warning signal when at fully open
or at open mid-stop.
• Connect a green light to the R2 terminals on the TLS1CARD. This will signal that the door is fully open or at the open mid-stop
position.
• Connect an audio/visual signalling device to the R3 terminals on the TLS1CARD. This will signal that the door is closing.
Inputs:
• If the application warrants the use of Timer Secure mode at some times and Timer modes at other times, set the operator selector
dial to TS and make a connection to the T/TS input. The input should have a latched contact, such as a 2-position maintained
keyswitch to switch between TS and T.
• If the application requires the ability to turn off the flash feature, connect a selector switch to the FD/SIS input terminals for a
flasher defeat. The input device should have a latched contact, such as a 2-position maintained keyswitch. A jumper wire can also
be used to disable the flash function.


Product specificaties

Merk: Liftmaster
Categorie: Niet gecategoriseerd
Model: TLS1CARD

Heb je hulp nodig?

Als je hulp nodig hebt met Liftmaster TLS1CARD stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Liftmaster

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd