Liftmaster HDLGARM Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Liftmaster HDLGARM (8 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 48 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
Swing Gate Operator Long Arm Kit
Model HDLGARM
To reduce the risk of SEVERE INJURY or DEATH:
Disconnect power (AC solar and battery) before servicing or
installing operator.
Turn both the AC and battery switches to off position.
Set the reset switch to the disconnect position.
WARNING: This product can expose you to chemicals including
lead, which are known to the State of California to cause cancer
or birth defects or other reproductive harm. For more information
go to www.P65Warnings.ca.gov
ATTENTION:
A SOLID BRACKET IS ATTACHED TO SHORT ARM LINK ON PACKAGING
FOR SHIPPING PURPOSES ONLY. PLEASE FOLLOW THE INSTRUCTIONS
FOR ARM ASSEMBLY.
Introduction
The long arm kit is for use with LiftMaster®gate operator model HDSW24UL. To optimize performance and extend operator life, the long arm kit is
recommended when installing with gates 16 ft. or longer.
See installation manual for gate operator model HDSW24UL for complete installation and safety instructions.
Determine Location for Concrete Pad and Operator
Refer to the illustration to determine the measurements and location of the concrete pad.
Inside
Outside Inside
Outside
A
F
B
C
D
10"
(25.4 cm)
DISTANCE
E
Long Arm Section
Short Arm Section
Concrete Pad
Gate Hinge Center
NOTE: There should only
be a maximum of
4" (10.2 cm) from the
center of the hinge to the
edge of the post or
column. If the distance is
greater than 4" (10.2 cm),
entrapment protection for
this area is required.
D MINUS 10"
(25.4 cm)
Dimension ( ) thru ( ) are from the center of one pivot point to the center of another pivot point.A E
Suggestion: The dimensions between the gate and the concrete pad is always 10 inches (25.4 cm) less than the dimension D.
Example: D = 42" (106.7 cm), if the dimensions between the gate and the concrete pad is 32" (81.3 cm).
Chart LA
Requires less clearance between gate and wall.
GATE LENGTH A B C D E F DISTANCE
22 ft.
2,500 lbs.max. 88" (2.24 m) 62.5" (1.58 m) 57.5" (1.46 m) 71" (1.80 m) 11" (27.9 cm) 3" (7.6 cm) 70" (1.78 m)
20 ft.
2,750 lbs. max. 80" (2.03 m) 58.25" (1.48 m) 52.25" (1.33 m) 65.5" (1.66 m) 11" (27.9 cm) 3" (7.6 cm) 65.75" (1.67 m)
18 ft,
3,250 lbs. max. 72" (1.83 m) 53" (1.35 m) 47" (1.19 m) 58.5" (1.49 m) 11" (27.9 cm) 3" (7.6 cm) 60.5" (1.54 m)
16 ft.
3,750 lbs. max. 64" (1.63 m) 48.25" (1.23 m) 41.75" (1.06 m) 52.5" (1.33 m) 11" (27.9 cm) 3" (7.6 cm) 55.75" (1.42 m)
14 ft.
4,500 lbs. max. 56" (1.42 m) 44.75" (1.14 m) 37.25" (.95 m) 50" (1.27 m) 11" (27.9 cm) 3" (7.6 cm) 52.25" (1.33 m)
Chart LB - Requires More Clearance Between Gate and Wall
Requires more clearance between gate and wall. Recommended on retrofit installations when operator being replaced is other than LiftMaster ®.
GATE LENGTH A B C D E F DISTANCE
22 ft.
2,500 lbs.max. 88" (2.24 m) 66.25" (1.68 m) 57.25" (1.45 m) 71" (1.80 m) 15" (38.1 cm) 3" (7.6 cm) 73.75" (1.87 m)
20 ft.
2,750 lbs. max. 80" (2.03 m) 61.75" (1.57 m) 52" (1.32 m) 65.5" (1.66 m) 15" (38.1 cm) 3" (7.6 cm) 59.25" (1.51 m)
18 ft.
3,250 lbs. max. 72" (1.83 m) 56.5" (1.44 m) 46.75" (1.19 m) 58.5" (1.49 m) 15" (38.1 cm) 3" (7.6 cm) 64" (1.63 m)
16 ft.
3,750 lbs. max. 64" (1.63 m) 51.75" (1.31 m) 41.5" (1.05 m) 52.5" (1.33 m) 15" (38.1 cm) 3" (7.6 cm) 59.25" (1.51 m)
14 ft.
4,500 lbs. max. 56" (1.42 m) 48.25" (1.23 m) 37" (.94 m) 50" (1.27 m) 15" (38.1 cm) 3" (7.6 cm) 55.75" (1.42 m)
Install the Long Arm
1. Remove the existing output arm from the operator.
2. Attach the long arm to the operator using the long output arm
included in the kit.
Existing
Output Arm
Long Arm
Assembly
1Long Output Arm
2
Secure the Operator Arm
The length of the arm can be adjusted if necessary. If adjusting the
length, ensure that both sections of the arm are adjusted proportionally.
Use a clamp to temporarily hold the arm in place while determining the
correct measurements.
1. Weld the gate bracket to the gate.
2. Weld the short arm section. Plug/slot weld top and bottom.
3. Weld the long arm section. Plug/slot weld top and bottom.
NOTE: Completely weld around the outer tubing and bracket.
4. Adjust the nuts on the operator arm so the operator arm fits snug on
the output shaft yet still allows enough room to swivel (the handle
must be in a 90° position).
5. Tighten the handle by pushing it down. Test to make sure the
operator arm does not slip on the output shaft.
Manual release handle
1
3
45
2
Trousse de bras long d’actionneur de
barrre pivotante
Modèle HDLGARM
Pour réduire le risque de BLESSURES GRAVES, voire MORTELLES:
DÉCONNECTER l’alimentation (c.a. solaire ou à batterie) AVANT
de procéder à l’installation de l’actionneur ou à une intervention
d’entretien sur celui-ci.
Mettre hors fonction les deux interrupteurs d’alimentation c.a. et
par batterie.
gler le commutateur de réinitialisation à la position RESET.
AVERTISSEMENT: Ce produit peut vous exposer à des produits
chimiques, y compris du plomb, reconnus par l’État de la
Californie comme étant cancérigènes ou pouvant causer des
anomalies congénitales ou d’autres préjudices à l’appareil
reproducteur. Pour plus d’information, aller à
www.P65Warnings.ca.gov
ATTENTION:
UN SUPPORT MASSIF EST FIXÉ À LA BIELLE DU BRAS COURT SUR
L’EMBALLAGE À DES FINS D’EXPÉDITION UNIQUEMENT. PRIÈRE DE
SUIVRE LES INSTRUCTIONS POUR L’ASSEMBLAGE DU BRAS.
Introduction
La trousse de biellette longue est prévue pour être utilisée sur l’actionneur de barrière LiftMaster ®de modèle HDSW24UL. Pour optimiser et prolonger la
vie utile de lactionneur, la trousse de biellette longue est recommandée lors de linstallation de barrières de 4,87m (16pi) ou plus.
Consulter le manuel d’installation de l’actionneur de barrière de modèle HDSW24UL pour des instructions complètes d’installation et de sécurité.
Détermination de l’emplacement de la dalle en béton et de l’actionneur
Consulter lillustration pour déterminer les mesures et lemplacement de la dalle en béton.
A
F
B
C
D
25.4 cm
(10 po)
DISTANCE
E
Section de bras long
Section de bras court
Dalle en béton
Centre de la charnière de barrière
D MOINS
25,4 cm (10 po)
Intérieur
Intérieur
Extérieur
Extérieur REMARQUE : La distance
maximale du centre de la
charnière au bord du poteau ou
de la colonne ne devrait pas
dépasser 10,2 cm (4 po). Si cette
distance est supérieure à 10,2 cm
(4 po), un dispositif de protection
contre le piégeage est alors
nécessaire pour cette zone.
Dimension ( ) à ( ) du centre d’un point de pivot au centre d’un autre point de pivot.A E
Suggestion: Les dimensions entre la barrière et la dalle en ton sont toujours de 25,4cm (10po) de moins que la dimensionD.
Exemple: D = 106,7cm (42), si la dimension entre la barrière et la dalle de ton est de 81,3cm (32po).
Tableau LA
cessite un moins grand dégagement entre la barrière et le mur.
LONGUEUR DE LA
BARRIÈRE A B C D E F DISTANCE
6,71m (22pi)
1134kg (2500lb) max. 2,24m (88po) 1,58m (62,5po) 1,46m (57,5po) 1,8m (71po) 27,9cm (11po) 7,6cm (3po) 1,78m (70po)
6,1m (20pi)
1247kg (2750lb) max. 2,03m (80po) 1,48m (58,25po) 1,33m (52,25po) 1,66m (65,5po) 27,9cm (11po) 7,6cm (3po) 1,67m (65,75po)
5,48m (18pi),
1474kg (3250lb) max. 1,83m (72po) 1,35m (53po) 1,19m (47po) 1,49m (58,5po) 27,9cm (11po) 7,6cm (3po) 1,54m (60,5po)
4,88m (16pi)
1701kg (3750lb) max. 1,63m (64po) 1,23m (48,25po) 1,06m (41,75po) 1,33m (52,5po) 27,9cm (11po) 7,6cm (3po) 1,42m (55,75po)
4,27m (14pi)
2041kg (4500lb) max. 1,42m (56po) 1,14m (44,75po) 0,95m (37,25po) 1,27m (50po) 27,9 cm (11po) 7,6cm (3po) 1,33m (52,25po)


Product specificaties

Merk: Liftmaster
Categorie: Niet gecategoriseerd
Model: HDLGARM

Heb je hulp nodig?

Als je hulp nodig hebt met Liftmaster HDLGARM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Liftmaster

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd