AUTOMATIC GARAGE DOOR LOCK
Model 841LM
Before you begin
Installation
For use on Residential Garages with an Entry Door Only. Install On Sectional Doors with Torsion
Assemblies Only. This product is intended for installation only by trained garage door technicians.
Please read and save these instructions with the instruction manual of the garage door opener.
Up to two locks can be installed per compatible garage door opener.
This automatic garage door lock is compatible with LiftMaster
® garage door openers with a
Security Shield.
Carton Inventory: Automatic Garage Door Lock, Template, 1/4"-20x1/2" Screws (2), 33' (10 m) Wire
Tools needed: Stepladder, Drill, 5/16" and 3/4" Drill Bits, Tape Measure, Screwdriver
UNPLUG THE GARAGE DOOR OPENER AND DISCONNECT THE BATTERY (IF APPLICABLE)
BEFORE PROCEEDING. REMOVE ANY MANUAL LOCKS FROM THE GARAGE DOOR.
FOR WALL MOUNT GARAGE DOOR OPENERS CONSULT THE GARAGE
DOOR OPENER MANUAL FOR INSTALLATION STEPS.
Attach template (provided) to track.
TIP: The second roller from the bottom is ideal for
most installations.
Drill holes as marked on template.
Fasten automatic garage door lock to the outside of
the garage door track with the 1/4"-20x1/2" screws.
Run wire (provided) from automatic garage door
lock to garage door opener. Use insulated staples
(not provided) to secure wire in several places.
NOTE: If you are going to cut the wire you will
need to reconnect wire using a wire nut. Do not
tape the ends together. The lock is polarized and
requires you reconnect black to black and white to
white wires.
Plug the connector into one of the lock terminals
on the garage door opener.
NOTE: To install a second automatic garage door
lock, repeat installation steps on the opposite side
of the garage door.
To prevent possible SERIOUS INJURY or DEATH from a closing gate or door:
Automatic Garage Door Lock MUST be installed per the owner’s manual.
Be sure to DISCONNECT ALL ELECTRIC AND BATTERY POWER to the garage door opener
BEFORE installing the garage door lock.
The door MUST be in the fully opened or closed position BEFORE installing the garage door lock.
Be sure to DISASSEMBLE and REMOVE any manual door locks that might be currently installed.
1
2
3
4
5
Approx. 3"
(7.6 cm)
Lock
terminals
123
4
5
WARNING: This product can expose you to chemicals including lead, which are known to
the State of California to cause cancer or birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov
Operation
Typical Operation
1. With the garage door fully closed, the automatic garage door lock bolt should be protruding
through the track.
2. Open the garage door. The automatic garage door lock should retract before the garage door begins
to move.
3. Close the garage door. When the garage door reaches the fully closed position, the automatic
garage door lock should automatically activate to secure the door.
Manual Operation
1. The garage door should be fully closed, if possible.
2. Disengage the automatic garage door lock by sliding the manual release to the open position.
3. Pull the emergency release handle down and back (toward the garage door opener). The garage
door can then be raised and lowered manually as necessary.
4. To reconnect the trolley, pull the emergency release handle straight down. The trolley will reconnect
on the next UP or DOWN operation.
NOTE: The automatic garage door lock will re-engage when garage door opener operation resumes.
Manual
release
To Disconnect Trolley
Emergency
release handle
To Reconnect Trolley Trolley Connected
Troubleshooting
The garage door doesn’t open completely:
Ensure any manual locks are removed from the garage door.
Is something obstructing the garage door? Is the automatic garage door lock in the locked
position? Is the garage door out of balance? Are the springs broken? Remove the obstruction
or repair the garage door.
Automatic garage door lock does not activate when garage door opens or closes:
Ensure your garage door opener is compatible with the automatic garage door lock. All
compatible garage door openers have a Security Shield icon on the outside cover.
Ensure the automatic garage door lock connector is plugged into the logic board correctly.
The wires for the automatic garage door lock may be shorted. Inspect the door lock wire at all
staple points and connection points and replace wire as needed.
Move lock door connector to secondary terminal.
Call a LiftMaster Dealer for replacement automatic garage door lock. If the problem persists,
you may need to replace the garage door opener logic board or transformer.
The garage door opener won’t operate due to power failure:
In battery backup mode, the automatic garage door lock will unlock when the garage door is
opened, and will remain disabled until power is restored.
If the garage door opener battery charge is depleted, use the Manual Operation process.
When power is restored, follow trolley re-engage steps. The automatic garage door lock will
work normally.
If the above recommendations do not fi x the problem please refer to your original garage door
opener manual for additional troubleshooting information.
Warranty
ONE YEAR LIMITED WARRANTY
LiftMaster warrants to the fi rst consumer purchaser of this product that it is free from defect in
materials and/or workmanship for a period of 1 year from the date of purchase.
SERRURE AUTOMATIQUE DE PORTE DE GARAGE
Modèle 841LM
Avant que tu commences
Installation
Réservé strictement à l’usage dans les garages résidentiels avec porte d’entrée. Installer uniquement sur
les portes articulées avec assemblages de torsion. Ce produit est prévu pour être installé uniquement par des
techniciens formés en installation de portes de garage. Prière de lire et conserver ces instructions de même que le
manuel de l’ouvre-porte de garage.
Jusqu’à deux serrures peuvent être installées par ouvre-porte de garage compatible.
Cette serrure automatique de porte de garage est compatible avec les ouvre-portes LiftMaster® avec
Security Shield.
Contenu de la boîte d’emballage: Serrure automatique de porte de garage, gabarit, vis de 1/4 de po-20x1/2 de
po (2), fi l de 10m (33pi)
Outils Nécessaires : Escabeau, perceuse, mèches de 5/16 et de 3/4 de po, ruban à mesurer, tournevis
DÉBRANCHER LOUVRE-PORTE DE GARAGE ET DÉCONNECTER LA BATTERIE (S’IL Y A LIEU) AVANT
DE PROCÉDER. RETIRER TOUTES LES SERRURES MANUELLES DE LA PORTE DE GARAGE.
POUR LES OUVRE-PORTES DE GARAGE À MONTAGE MURAL, CONSULTER LES ÉTAPES
D’INSTALLATION DANS LE MANUEL DE LOUVRE-PORTE DE GARAGE.
Fixer le gabarit (fourni) au rail.
CONSEIL : Le deuxième galet à partir du bas est idéal
pour la plupart des installations.
Percer des trous aux endroits marqués sur le gabarit.
Fixer la serrure automatique de porte de garage à
l’extérieur du rail de la porte de garage avec les vis de
1/4 de po-20x1/2 de po.
Acheminer le l (fourni) de la serrure automatique de
porte de garage à l’ouvre-porte de garage. Utiliser des
agrafes isolées (non fournies) pour fi xer le fi l à plusieurs
endroits.
REMARQUE : S’il faut couper le fi l, celui-ci doit être
raccordé avec un capuchon de connexion. Ne pas coller
les extrémités ensemble avec du ruban. La serrure est
polarisée et exige de raccorder le fi l noir au l noir et le
blanc au blanc.
Brancher le connecteur dans l’une des bornes de la
serrure sur l’ouvre-porte de garage.
REMARQUE : Pour installer une deuxième serrure
automatique de porte de garage, répéter les étapes
d’installation de l’autre côté de la porte de garage.
1
2
3
4
5
Pour prévenir d’éventuelles BLESSURES GRAVES, voire MORTELLES lorsqu’une porte ou une barrière se ferme :
La serrure automatique de porte de garage DOIT être installée conformément aux instructions du manuel du
propriétaire.
S’assurer de DÉCONNECTER TOUTE ALIMENTATION électrique ou par batterie à l’ouvre-porte de garage
AVANT de procéder à l’installation de la serrure de porte de garage.
La porte DOIT être complètement ouverte ou complètement fermée AVANT d’installer les cellules
photoélectriques.
S’assurer de DÉSASSEMBLER et de RETIRER toutes les serrures manuelles actuellement installées.
AVERTISSEMENT : Ce produit peut vous exposer à des produits chimiques comme le plomb, reconnu par
l’État de la Californie comme cause de cancers, d’anomalies congénitales et d’autres problèmes liés à la
reproduction. Pour plus d’informations, visitez www.P65Warnings.ca.gov
Environ
7,6 cm (3 po)
123
4
5
Bornes de
verrouillage


Product specificaties

Merk: Liftmaster
Categorie: Niet gecategoriseerd
Model: 841LM

Heb je hulp nodig?

Als je hulp nodig hebt met Liftmaster 841LM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Liftmaster

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd