Bekijk gratis de handleiding van Liberty Pumps AE34=3-171 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 10 mensen en kreeg gemiddeld 4.0 sterren uit 2 reviews. Heb je een vraag over Liberty Pumps AE34=3-171 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
PROGRAMMING INSTRUCTIONS
WITH POWER ON, HOAs OFF, FLOATS OFF OR DISCONNECTED, PRESS DESIRED FLOAT BUTTON RAPIDLY 4 TIMES AND HOLD
**PUMP LEDs WILL FLASH UPON SUCCESSFUL PROGRAMMING**
OPTIONSFLOAT BUTTONDEFAULTOPERATION
PUMP FAIL ALARMSTOPONACTIVATES IF A PUMP CAUSES “LAG” 3 CYCLES IN A ROW
MANUAL ALARM RESETLEADOFFLATCHES HIGH ALARM: CLEAR WITH EXTERNAL TEST SWITCH
SEAL FAIL HORNLAGOFFACTIVATES HORN UPON SEAL FAIL
ALARM FLASHERALARMOFFFLASHES BEACON UPON HIGH ALARM
ALARM CONDITIONS
ALARMBEACONCONTROLLER LEDHORN
PUMP FAILFLASHINGRED PUMP LIGHTNO
SEAL FAILFLASHINGSF1, SF2PROG
FLOAT FAILFLASHINGBAD FLOAT NOT LITNO
HIGH ALARMSOLIDALARM FLOATYES
STOPLEADLAGALARM
PUMP
1
PUMP
2
HAND
AUTO
HAND
AUTO
NO C NC
OFF
1-2 ALT 2-1
SF1
SF2
25K
5K
NC
150K
100K
125K50K
15K
OFF ON
TESTTESTTESTTEST
SEAL FAIL
POWER
3
4
1
2
5
6
7
8
9
10
AUX
1-2 ALT 2-1
SF1
SF2
SEAL FAIL
LEAD / LAG
SELECTOR
25K
5K
NC
150K
100K
125K50K
15K
SF1
100K
LAGALARM
TESTTESTTESTTESTTEST
AUX
CONTACTS
NO C NC
678910
TB2
H
O
A
TM
H
O
A
PUMP 1PUMP 2
H
O
A
PUMP 1PUMP 2
H
O
A
H
O
A
TM
H
O
A
1-2 ALT 2-1
LEAD / LAG
SELECTOR
PUMP 1PUMP 1
STOP
TESTTEST
H
O
A
L1 N
ON OFF
12
TM
H
O
A
43
1054970
DUPLEX
CONTROLLER
PUMP 1PUMP 1
STOP
TESTTEST
H
O
A
L1 N
ON OFF
12
TM
H
O
A
4
3
1054970
DUPLEX
CONTROLLER
PUMP 1PUMP 2PUMP 1PUMP 2
STOPLEADLAGALARM
TESTTESTTESTTESTTESTTESTTEST
AUX
CONTACTS
NO C NC
45678910
3
TB1
L1 N
ON OFF
12
43
1054970
DUPLEX
CONTROLLER
TB1
ON OFF
L1 N
ON OFF
12
1054970
DUPLEX
CONTROLLER
TB1
AUX
CONTACTS
NO C NC
10
STOPLEADLAGALARM
PUMP
1
PUMP
2
HAND
AUTO
HAND
AUTO
NO C NC
OFF
1-2 ALT 2-1
SF1
SF2
25K
5K
NC
150K
100K
125K50K
15K
OFF ON
TESTTESTTESTTEST
SEAL FAIL
POWER
3
4
1
2
5
6
7
8
9
10
AUX
SF1
100K
LAGALARM
TESTTESTTESTTESTTEST
AUX
CONTACTS
NO C NC
678910
TB2
PUMP 1PUMP 2PUMP 1PUMP 2
STOPLEADLAGALARM
TESTTESTTESTTESTTESTTESTTEST
AUX
CONTACTS
NO C NC
45678910
3
TB1
L1 N
3
TB1
PUMP 1PUMP 1
STOP
TESTTEST
H
O
A
L1 N
ON OFF
12
TM
H
O
A
43
1054970
DUPLEX
CONTROLLER
PUMP 1PUMP 1
H
O
A
H
O
A
OFFON
POWER
1
2
22650 County Highway 6
Detroit Lakes, MN 56501 USA
Tel: 218-847-1317
Web: www.sjerhombus.com
PUMP 1PUMP 2
H
O
A
PUMP 1PUMP 2
H
O
A
STOPLEADLAGALARM
TESTTESTTESTTESTTESTTESTTEST
AUX
CONTACTS
H
O
A
L1 N
ON OFF
12
H
O
A
NO C NC
456789103
1-2 ALT 2-1
SF1
SF2
SEAL FAIL
LEAD / LAG
SELECTOR
25K
5K
NC
150K
100K
125K50K
15K
1058484A
TB1TB2
DUPLEX
CONTROLLER
1055156
a
b
c
e
d
g
l
k
i
j
h
COMPONENTS
a. ON/OFF Switch - Control/Alarm Powerg. Simulate Float Buttons x4
b. 120V Incoming Power Terminalsh. Float Terminals x8
c. Power LED - (Green)i. Lead/Lag Selecter Switch
d. Pump HOA Switchesj. Dual Seal Fail Pot - (Optional)
e. Float LEDs - (Red) x4k. Dual Seal Fail LEDs - (Red) - (Optional)
f. Pump LEDs
Pump Run - (Green)
Pump Fail - (Red)
l. Auxiliary Alarm Terminals
Model shown contains optional Seal Fail circuitry.
Three Phase Duplex
This control panel must be installed and serviced by a licensed electrician in
accordance with the National Electric Code NFPA-70, state and local electrical codes.
UL Type 4X enclosures are for indoor or outdoor use.
Warranty void if panel is modied.
A Family and Employee Owned Company
Liberty Pumps oers a three-year limited warranty.
For complete terms and conditions, please visit www.libertypumps.com.
Products returned must be cleaned, sanitized, or decontaminated as necessary
prior to shipment to ensure that employees will not be exposed to health
hazards in handling said material. All applicable laws and regulations shall apply.
?
Three Phase
Duplex
Installation
and Operation Manual
This control panel must be installed
and serviced by a licensed electrician
in accordance with the National Electric
Code NFPA-70, state and local electrical
codes.
UL Type 4X enclosures are for indoor or
outdoor use.
Technical support,
service questions:
1-800-543-2550
Monday - Friday
7:00 AM to 6:00 PM EST
?
Manufactured by SJE Rhombus®
AE4=3-131, AE34=3-141, AE34=3-171,
AE34=3-191, AE34=3-511, AE34=4-131,
AE34=4-141, AE34=4-171, AE34=4-191,
AE34=4-511, AE54=3-121, and AE54=4-121
Parts Included
x3
or
x4
Control panel may be
ordered with or
without these items.
x4
AE34=3-131, AE34=3-141, AE34=3-171,
AE34=3-191, AE34=3-511, AE34=4-131,
AE34=4-141, AE34=4-171, AE34=4-191,
AE34=4-511, AE54=3-121, and AE54=4-121
Installation and Operation Manual
Manufactured by SJE Rhombus
®
Call factory with servicing questions:
1-800-543-2550
f
© 2019 SJE, Inc. All Rights Reserved.
SJE RHOMBUS is a trademark of SJE, INC.
PN 1038909E • Rev 08/19
Copyright © Liberty Pumps, Inc. 2019 All rights reserved. Specications subject to change without notice. 7228000E P4
7000 Apple Tree Avenue Bergen, NY 14416
Phone 800-543-2550
Fax 585-494-1839
Web www.LibertyPumps.com
Copyright © Liberty Pumps, Inc. 2019 All rights reserved. Specications subject to change without notice. 7228000E P1
7000 Apple Tree Avenue Bergen, NY 14416
Phone 800-543-2550
Fax 585-494-1839
Web www.LibertyPumps.com
Cable Weight available
separately. Order Liberty
Pumps Kit #001388

Beoordeel deze handleiding

4.0/5 (2 Beoordelingen)

Product specificaties

Merk: Liberty Pumps
Categorie: Niet gecategoriseerd
Model: AE34=3-171

Heb je hulp nodig?

Als je hulp nodig hebt met Liberty Pumps AE34=3-171 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden