LG LB-F4280HL Handleiding

LG Airco LB-F4280HL

Lees hieronder de 📖 handleiding in het Nederlandse voor LG LB-F4280HL (18 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 30 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/18
CEILING DUCT TYPE AIR CONDITIONERS
INSTALLATION INSTRUCTIONS
• Please read this instruction sheet completely before installing the product.
• When the power cord is wanted to replace, replacement work shall be performed by authorized
personnel only.
• Installation work must be performed in accordance with national wiring standards by authorized
personnel only.
P/No.: 3828A30021V
Air lters
Remote Controller
(Side) (Rear)
Air intake vents
Air intake vents
Air outlet vents
Piping
Drain hose
Connecting wire
Control cover
Air outlet vents
(Side) (Rear)
Air outlet
vents
Air intake
vents
Connecting Wire
Drain Hose
Connection Pipe
Control Cover
Indoor Unit
Outdoor Unit
ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH
1.The following should be always observed for safety ...............................3
2. Installation of Indoor, Outdoor unit
3. Connecting Pipes to the Indoor Unit
4. Connecting Pipes to the Outdoor Unit
5. Checking the Drainage ..............................................................................14
6. Connecting Cables between Indoor Unit and Outdoor Unit
7. Air Purging of the Connecting Pipes and the Indoor Unit ....................18
OUT-LINE OF INSTALLATION
Installation works Installation Parts Required tools
1)
Selection of the best
location
............................4
2) Indoor unit installation....5
Four Type “A” screws
Connecting cable
Level
Screw driver
Electric drill
Hole core drill (ø70mm)
1) Preparation of Piping...12
Pipes: Gas side .....1/2", 5/8", 3/4"
Liquid side ............. 1/4", 3/8", 1/2"
Insulated drain hose
Insulation materials
Flaring Tools set
1) Connecting the pipes to
the Outdoor Unit ..........14
Additional Drain hose
(Inner Dia...............25mm)
1) Connecting cables to the
Indoor Unit ...................15
2) Connecting cables to the
Outdoor Unit ................16
3) Form the pipings..........17
Screw driver
Hexagonal Wrench (4mm/5mm)
Gas-leak Detector
2
ENGLISH
3
1. The following should be always observed for safety
• Please report to or take consent by the supply authority before connecting to the system.
• Be sure to read "THE FOLLOWING SHOULD BE ALWAYS OBSERVED FOR SAFETY" before
installing the air conditioner.
• Be sure to observe the cautions specied here as they include important items related to safety.
• The indications and meanings are as follows.
• After reading this manual, be sure to keep it together with the instruction manual in a handy place .
Could lead to death, serious injury, etc.
Do not install it yourself (customer).
Perform the installation securely referring to the
installation manual.
Install the unit securely in a place which can bear the
weight of the unit. Perform electrical work according to the installation
manual and be sure to use an exclusive circuit.
Attac t cover to the indoor unit andh the electrical par
the service panel to the outdoor unit securely.
Be sure to use the part provided or specified parts for
the installation work.
Check that the refrigerant gas do not leak after
installation is completed.
Perf ork securelyorm the drainage/piping w
according to the installation manual.
Use the specified wires to connect the indoor and the
outdoor units securely and attach the wires firmly to
the terminal board connecting sections so the stress
of the wires is not applied to the sections.
Incomplete installation could cause injur ic shock,y due to fire, electr
the unit falling or a leakage of water. Consult the dealer from whom
you purchased the unit or special installer.
• Incomplete installation could cause a personal injury due to
re, electric shock, the unit falling or a leakage of water.
• When installed in an insucient strong place, the unit could fall
causing injured.
• Incomplete connecting and xing could cause re.
If the capacity of the power circuit is insufficient or there is
incomplete electrical w k, it could result in a fire or an electricor
shock.
The use of defective parts could cause an injury or leakage of
water due to a fire, electric shock, the unit falling, etc.
• If there is a defect in the drainage/piping work, water
could drop from the unit and household goods could be
wet and damaged.
Do not install the unit in a place where an
inflammable gas leaks.
If gas leaks and accumulates in the area surrounding the unit, it
could cause an explosion.
If the electrical part cover if the indoor unit and/or the service
panel if the outdoor unit are not attached securely, it could result
in a fire or electric shock due to dust, water, etc.
Could lead to serious injury in particular environments when operated incorrectly.
WARNING
WARNING
CAUTION
CAUTION


Product specificaties

Merk: LG
Categorie: Airco
Model: LB-F4280HL

Heb je hulp nodig?

Als je hulp nodig hebt met LG LB-F4280HL stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco LG

Handleiding Airco

Nieuwste handleidingen voor Airco