Klein Tools CL2000 Handleiding
Klein Tools Meetapparatuur CL2000
Bekijk gratis de handleiding van Klein Tools CL2000 (2 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 19 mensen en kreeg gemiddeld 4.3 sterren uit 8 reviews. Heb je een vraag over Klein Tools CL2000 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
www.kleintools.com
139540T Rev. 11/13 B
ENGLISH
• TRUE RMS
• AUTO / MANUAL
RANGE
• NON CONTACT
VOLTAGE TESTER
• RELATIVE / ZERO
• BAR GRAPH
• MAX / MIN / HOLD
• 3-3/4 DIGIT
3999 COUNT LCD
• BACKLIGHT
• WORKLIGHT
V
AT
010204030
Apo
600V
400A
CATIII
CL2000
ENGLISH
8. Non Contact Voltage (NCV):
>
25V AC
SYMBOLS USED ON LCD
~
AC MeasurementDC Measurement
-
Negative DC Value
AT
Auto Range Active
O
.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
M
AX
Maximum Reading
%
Duty Cycle ModeFrequency Mode
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in OhmsDiode Test
F
Capacitance in FaradsContinuity Test
Relative / Zero Mode
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
RangeResolutionAccuracy
400mV
˜
400V0.1mV
˜
0.1V± (0.5% + 4 digits)
1000V1V± (0.8% + 10 digits)
Overload Protection: 1000V
AC Voltage Measurement
RangeResolutionAccuracy
400mV
˜
750V0.1mV
˜
1V± (2.0% + 5 digits)
Overload Protection: 750V RMS
Frequency Response: 40 to 400Hz
Minimum Voltage for Frequency Measurement: 200mV
Response: True RMS
Continuity Test
Overload ProtectionOpen Circuit Voltage
600V RMS< 0.44V
Non Contact Voltage Detector
On Voltage
Appx. 25V AC
DC Current Measurement
RangeResolutionAccuracy
400µA0.1µA
± (1.2% + 3 digits)
2000µA1µA
40A0.01A± (2.5% + 15 digits)
400A0.1A± (1.5% + 8 digits)
Overload Protection:
• Voltage: 600V RMS
• Current: 2000µA
AC Current Measurement
RangeResolutionAccuracy
400µA0.1µA± (2.0% + 5 digits)
2000µA1µA± (1.5% + 5 digits)
40A0.01A± (2.9 % + 15 digits)
400A0.1A± (1.9% + 8 digits)
Overload Protection:
• Voltage: 600V RMS
• Current: 2000µA
Frequency: 45 to 400Hz
Minimum Current for Frequency Measurement: 400µA or 20A
Response: True RMS
Resistance Measurement
RangeResolutionAccuracy
400
Ω
˜
4MΩ0.1Ω
˜
0.001MΩ
± (1.0% + 4 digits)
40M
Ω0.01MΩ
± (2.0% + 4 digits)
Overload Protection: 600V RMS
Capacitance Measurement
RangeResolutionAccuracy
40nF
˜
4000µF0.01nF
˜
1µF± (3.5% + 6 digits)
Overload Protection: 600V RMS
Frequency Measurement
RangeResolutionAccuracy
9.999Hz
˜
999.9kHz0.001Hz
˜
0.1kHz± (0.1% + 4 digits)
Overload Protection: 600V RMS
Duty Cycle Measurement
RangeResolutionAccuracy
0.1
˜
99.9%0.1%± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection: 600V RMS
Diode Test
Overload ProtectionRangeTest CurrentOpen Circuit Voltage
600V RMS2.0VAppx. 0.25mA< 1.6V DC
600V
400V
CATIII
CL1000
PRESS
and
HOLD
PRESS
and
HOLD
WARRANTY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution: This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
750V
1000V
400A
Dwg Name:CL2000-139540TART Dwg No:139540T
ECO No:14678 Pkg Dwg Ref:1650Rev: B
Color Reference:CEN-PACK-003-A
Instruction Manual
CL2000
CL2000 Instruction Manuals - MASTER.indd 1-411/20/2013 2:54:10 PM
Product specificaties
| Merk: | Klein Tools |
| Categorie: | Meetapparatuur |
| Model: | CL2000 |
Heb je hulp nodig?
Als je hulp nodig hebt met Klein Tools CL2000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Klein Tools
8 Juli 2025
14 April 2025
13 Januari 2025
13 Januari 2025
18 November 2024
12 November 2024
24 September 2024
21 September 2024
21 September 2024
18 Juni 2024
Handleiding Meetapparatuur
Nieuwste handleidingen voor Meetapparatuur
21 Januari 2026
21 Januari 2026
21 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026
19 Januari 2026