For your convenience, write down the following
information. If you call our Consumer Hotline,
these are the first questions you will be asked.
9 Volt Battery-Operated Photoelectric Smoke
Alarm with “HUSH” Control to temporarily silence
nuisance alarms.
Thank you for purchasing this smoke alarm. It is an important
part of your family’s home safety plan. You can trust this
product to provide the highest quality safety protection.
We know you expect nothing less when the lives of your
family are at stake.
Smoke Alarm User Guide
Smoke Alarm Model Number
(located on back of alarm):
Date Code (located on back of alarm):
The National Fire Protection Association
(NFPA) and the manufacturer
recommend replacing this alarm
ten years from the date code.
Date of Purchase:
Where Purchased:
0306-7240-00 Rev.A
P9040
For model: P9040

WARNING! SmOke AlARm CAN NOt Be mOUNted
UNleSS BAtteRY IS PReSeNt. RemOVAl OF BAtteRY WIll
ReNdeR tHe SmOke AlARm INOPeRAtIVe.
ImPORtANt! ReAd All INStRUCtIONS BeFORe
INStAllAtION ANd keeP tHIS mANUAl NeAR tHe AlARm
FOR FUtURe ReFeReNCe.
CONteNtS OF tHIS mANUAl
1 -- ReCOmmeNded lOCAtIONS FOR SmOke AlARmS
2 -- lOCAtIONS tO AVOId
3 -- INStAllAtION INStRUCtIONS
4 -- OPeRAtION ANd teStING
5 -- NUISANCe AlARmS
6 -- mAINteNANCe
7 -- lImItAtIONS OF SmOke AlARmS
8 -- GOOd SAFetY HABItS
9 -- NFPA PROteCtION StANdARd 72
10 --
CAlIFORNIA StAte FIRe mARSHAl ReQUIRed INFORmAtION
11 -- SeRVICe ANd WARRANtY
1. RECOMMENDED LOCATIONS FOR ALARMS
• Locate the first alarm in the immediate area of the bedrooms.
Try to monitor the exit path as the bedrooms are usually farthest
from the exit. If more than one sleeping area exists, locate addi-
tional alarms in each sleeping area.
• Locate additional alarms to monitor any stairway as stairways act
like chimneys for smoke and heat.
• Locate at least one alarm on every floor level.
• Locate an alarm in every bedroom.
• Locate an alarm in every room where electrical appliances are
operated (i.e. portable heaters or humidifiers).
• Locate an alarm in every room where someone sleeps with the
door closed. The closed door may prevent an alarm not located
in that room from waking the sleeper.
• Smoke, heat, and combustion products rise to the ceiling and
spread horizontally. Mounting the smoke alarm on the ceiling in
the center of the room places it closest to all points in the room.
!

Ceiling mounting is preferred in ordinary residential construction.
• For mobile home installation, select locations carefully to avoid
thermal barriers that may form at the ceiling. For more details,
see MOBILE HOME INSTALLATION below.
• When mounting an alarm on the ceiling, locate it at a minimum
of 4” (10cm) from the side wall (see figure 1).
• When mounting the alarm on the wall, use an inside wall with
the top edge of the alarm at a minimum of 4” (10cm) and a
maximum of 12” (30.5cm) below the ceiling (see figure 1).
• Put smoke alarms at both ends of a bedroom hallway or large
room if the hallway or room is more than 30 ft (9.1m) long.
• Install Smoke Alarms on sloped, peaked or cathedral ceilings
at or within 3 ft (0.9m) of the highest point (measured hori-
zontally). NFPA 72 states: “Smoke alarms in rooms with ceiling
slopes greater than 1 ft in 8 ft (.3m in 2.4m) horizontally shall
be located on the high side of the room.” NFPA 72 states: “A
row of alarms shall be spaced and located within 3 ft (0.9m) of
the peak of the ceiling measured horizontally” (see figure 3).
Required
FIGURe 2 FIGURe 3
FIGURe 1
Product specificaties
Merk: | Kidde |
Categorie: | Rookmelder |
Model: | P9040 |
Heb je hulp nodig?
Als je hulp nodig hebt met Kidde P9040 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Rookmelder Kidde
5 September 2025
4 September 2025
4 September 2025
4 September 2025
2 September 2025
2 December 2024
16 November 2024
26 September 2024
26 September 2024
26 September 2024
Handleiding Rookmelder
- Honeywell
- Mercury
- Qolsys
- Eminent
- Mircom
- Pyrexx
- Gewiss
- AngelEye
- Clas Ohlson
- Pristine
- Hochiki
- CodeRED
- Meross
- Nest
- Malmbergs
Nieuwste handleidingen voor Rookmelder
2 September 2025
1 September 2025
1 September 2025
26 Augustus 2025
11 Augustus 2025
27 Juli 2025
9 Juli 2025
4 Juli 2025
4 Juli 2025
1 Juli 2025