Jung ES5201HYG Handleiding
Jung
Luchtbevochtiger
ES5201HYG
Bekijk gratis de handleiding van Jung ES5201HYG (7 pagina’s), behorend tot de categorie Luchtbevochtiger. Deze gids werd als nuttig beoordeeld door 49 mensen en kreeg gemiddeld 4.4 sterren uit 25 reviews. Heb je een vraag over Jung ES5201HYG of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/7

Temperature Management Hygrostat
Ref.-no.: ..5201 HYG..
Operating Instructions
Hygrostat
Table of contents
1. Safety instructions............................................................................ 2
2. Device layout ..................................................................................... 2
3. Function ............................................................................................. 2
3.1. Designated use ............................................................................. 2
3.2. Product features............................................................................ 3
3.3. Automatic mode............................................................................ 3
3.4. Manual mode ................................................................................ 3
3.5. Party mode.................................................................................... 3
3.6. Standby mode............................................................................... 3
4. Operation............................................................................................ 4
4.1. Setting the humiditiy manually ...................................................... 4
4.2. Dehumidifying the ambient air manually....................................... 4
4.3. Activating the party mode ............................................................. 4
4.4. Activating the standby mode......................................................... 4
4.5. Switching back to automatic mode ............................................... 5
4.6. Cleaning the hygrostat.................................................................. 5
5. Fitting and electrical connection..................................................... 5
5.1. Fitting and connecting the device ................................................. 5
6. Annex.................................................................................................. 7
6.1. Technical data............................................................................... 7
6.2. Help in case of trouble .................................................................. 7
6.3. Guarantee ..................................................................................... 7
Stand: Sep-09 325 658 03

Temperature Management Hygrostat
Ref.-no.: ..5201 HYG..
1. Safety instructions
Electrical equipment must be installed and fitted by qualified
electricians only.
Before working on the device, disconnect the supply voltage (by
cutting out the circuit breaker) to avoid the risk of an electric shock.
Failure to observe the instructions may cause damage to the device
and result in fire or other hazards.
In rooms with open fires such as fireplaces or gas cookers, room
ventilation systems may only be operated if additional protective
measures are taken. The applicable Building Regulations for hearth
and fireplace installations must be observed.
These operating instructions are part of the product and must be
left with the final customer.
2. Device layout
Fig 1: Front view
(1) Mode-of-operation selector
(2) Control knob
(3) Status LED
3. Function
3.1. Designated use
The hygrostat controls the humidity of the air in order to create agreeable
and healthy conditions in the room and helps to prevent the formation of
detrimental mould.
• Measurement of air humidity in rooms
• Control of 230 V heating and ventilation appliances
• Installation in a flush-mounting box in acc. with DIN 49073
2

Temperature Management Hygrostat
Ref.-no.: ..5201 HYG..
3.2. Product features
• Measurement of room temperature and air humidity to determine
the optimal content of moisture in the air
• Control of heating and ventilation appliances for the removal of
moisture in rooms
• Manual control range approx. 20…95 % or fixed value of 60 %
relative humidity
• Control knob for manual adjustment of the setpoint
• Modes of operation: automatic, manual, party, standby
• Status LED
• Time-controlled continuous operation
3.3. Automatic mode
When the air humidity exceeds the preset value, the hygrostat activates
the connected dehumidification appliance:
• LED yellow: off, LED , LED green: on red: off
When the air humidity is lower than the preset value, the hygrostat
deactivates the connected appliance:
• LED yellow: off, LED , LED green: off red: off
After one hour of continuous operation, the hygrostat switches off the
appliance for 4 hours:
• LED yellow: off off, LED green: , LED red: on
L If the content of water in the ambient air is very high, a
dehumidification by means of a fan is not possible.
3.4. Manual mode
Fan operation is activated manually for abt. one hour.
• LED yellow: on, LED , LED green: on red: off
3.5. Party mode
Fan operation is activated manually for abt. six hours.
• LED yellow: on, LED , LED green: on red: flashing
3.6. Standby mode
Fan operation is deactivated manually for abt. four hours.
• LED yellow: on, LED , LED green: off red: on
3
Product specificaties
Merk: | Jung |
Categorie: | Luchtbevochtiger |
Model: | ES5201HYG |
Heb je hulp nodig?
Als je hulp nodig hebt met Jung ES5201HYG stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Luchtbevochtiger Jung
26 Mei 2023
29 April 2023
6 Maart 2023
1 Maart 2023
Handleiding Luchtbevochtiger
- Ionmax
- Royal Sovereign
- Topcom
- PureGuardian
- Lasko
- Jata
- Sharper Image
- Hyundai
- Panduit
- Scarlett
- Suntec
- IFM
- Philips
- Sogo
- Fibaro
Nieuwste handleidingen voor Luchtbevochtiger
17 Juni 2025
16 Juni 2025
15 Juni 2025
15 Juni 2025
4 Juni 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025