Bekijk gratis de handleiding van Jung 521ZNAUF (4 pagina’s), behorend tot de categorie Stopcontact. Deze gids werd als nuttig beoordeeld door 10 mensen en kreeg gemiddeld 4.5 sterren uit 5.5 reviews. Heb je een vraag over Jung 521ZNAUF of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/4

SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protectionSCHUKO socket with surge voltage protection
Art. no.: A521UF..
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protectionSCHUKO socket with surge voltage protection
Art. no.: 521ZNAUF
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protection
SCHUKO socket with surge voltage protectionSCHUKO socket with surge voltage protection
Art. no.: ..521NAUF..
Operating instructions
Operating instructions
Operating instructions
Operating instructionsOperating instructions
1
1
1
11 Safety instructions
Safety instructions
Safety instructions
Safety instructionsSafety instructions
Installation only by persons with appropriate electrotechnical knowledge and experience
Installation only by persons with appropriate electrotechnical knowledge and experience
Installation only by persons with appropriate electrotechnical knowledge and experience
Installation only by persons with appropriate electrotechnical knowledge and experienceInstallation only by persons with appropriate electrotechnical knowledge and experience
in the following areas:
in the following areas:
in the following areas:
in the following areas:in the following areas:
– The "5 safety rules" to be observed are: disconnect; secure against reconnection; determ-
ine that no voltage is present; ground and short-circuit; cover or block off adjacent live
parts
– Selection of suitable tools, measuring devices and, if necessary, personal protective
equipment
– Evaluation of the measurement results
– Selection of the electrical installation material to ensure the shutdown conditions
– IP degrees of protection
– Installation of the electrical installation material
– Type of mains supply (TN system, IT system, TT system) and the resulting connection re-
quirements (classic earthing, protective earthing, necessary additional measures, etc.)
Improper installation endangers your own life and the lives of users of the electrical system and
there is a risk of serious damage to property, e.g. through fire. You are at risk of personal liabil-
ity for personal injury and damage to property.
Contact an electrical contractor!
Contact an electrical contractor!
Contact an electrical contractor!
Contact an electrical contractor!Contact an electrical contractor!
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.Serious injuries, fire or property damage possible. Please read and follow manual fully.
To protect against high-energy surges, install multistage selective protection. Otherwise con-
To protect against high-energy surges, install multistage selective protection. Otherwise con-
To protect against high-energy surges, install multistage selective protection. Otherwise con-
To protect against high-energy surges, install multistage selective protection. Otherwise con-To protect against high-energy surges, install multistage selective protection. Otherwise con-
nected devices may be damaged.
nected devices may be damaged.
nected devices may be damaged.
nected devices may be damaged.nected devices may be damaged.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.These instructions are an integral part of the product, and must remain with the end customer.
2
2
2
22 Device components
Device components
Device components
Device componentsDevice components
Figure1: Device components
(1) Socket outlet
(2) Red light emitting diode = protection function not in operation
(3) Red light emitting diode = mains voltage present
1 / 4
32515863 22.06.2021
J0082515863

SCHUKO socket with surge voltage protection
3
3
3
33 Intended use
Intended use
Intended use
Intended useIntended use
– Type 3 fine protection for protecting electrical and electronic devices against transient
power surges according to EN 61643-11
– For use only in combination with Type 1 coarse protection and Type 2 medium protection
– For use in TN, TT and IT systems
– Stationary installation indoors in appliance box according to DIN 49073.
4
4
4
44 Instructions for operation
Instructions for operation
Instructions for operation
Instructions for operationInstructions for operation
– The device protects electrical and electronic devices against transient power surges.
– Failure of the protection function is indicated by an acoustic and visual signal.
– Keep cables between loads (5) and surge protection socket outlet (1) as short as possible,
max. 4 m.
– Do not lay protected cables parallel to unprotected cables. There is a danger of surge
voltage coupling.
– When performing insulation measurements on the system, all surge protection products
should always be disconnected, because otherwise the test voltage will be limited by the
protective modules, thus leading to incorrect measurements.
5
5
5
55 Information for electrically skilled persons
Information for electrically skilled persons
Information for electrically skilled persons
Information for electrically skilled personsInformation for electrically skilled persons
5.1
5.1
5.1
5.15.1 Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connectionFitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shock when live parts are touched.
Electrical shock when live parts are touched.
Electrical shock when live parts are touched.Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Electrical shocks can be fatal.
Electrical shocks can be fatal.
Electrical shocks can be fatal.Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the corresponding cir-
Before carrying out work on the device or load, disengage all the corresponding cir-
Before carrying out work on the device or load, disengage all the corresponding cir-
Before carrying out work on the device or load, disengage all the corresponding cir-Before carrying out work on the device or load, disengage all the corresponding cir-
cuit breakers. Cover up live parts in the working environment.
cuit breakers. Cover up live parts in the working environment.
cuit breakers. Cover up live parts in the working environment.
cuit breakers. Cover up live parts in the working environment.cuit breakers. Cover up live parts in the working environment.
Connecting and fitting the device
Connecting and fitting the device
Connecting and fitting the device
Connecting and fitting the deviceConnecting and fitting the device
Figure2: Connection diagram for single socket outlet
2 / 4
32515863 22.06.2021
J0082515863

SCHUKO socket with surge voltage protection
Figure3: Connection diagram for socket outlet combination
(1) Surge protection socket outlet
(4) Socket outlet with normal design
(5) Load
■ Connect surge protection socket outlet according to connection diagram for single socket
outlet (Figure 2) or connection diagram for socket outlet combination (Figure 3).
The maximum continuous voltage (see Technical data) must not be exceeded. In multiple
combinations, when a surge protection socket outlet is used the other socket outlets used
in the combination are also protected in the normal design. For this the socket outlets
have to be installed on the same conductor.
■ Install overvoltage protection socket outlet in appliance box.
■ Mount the cover and frame. Observe correct installation position. Otherwise the LED will
not function.
6
6
6
66 Technical data
Technical data
Technical data
Technical dataTechnical data
Overvoltage protection Type 3 arrester (one port)
Rated voltage AC AC 230 V ~ (± 10%)
Mains frequency 50 / 60 Hz
Maximum continuous voltage AC 255V~ (U
C
)
No-load voltage 4kV (U
OC
)
Rated load current 16A (I
L
)
Short circuit strength 1.5kA (I
SCCR
)
Protection level
L/N ≤ 1.25kV (U
P
)
L/PE;N/PE ≤ 1.25kV (U
P
)
TOV characteristic 442V/5s/120min (U
T
)
Circuit breaker max. 16A (gG/C)
Ambient temperature -5 ... +40 °C
Relative humidity 5 ... 95 % (no moisture condensation)
Clampable conductor cross-section 1.5 ... 2.5mm²
3 / 4
32515863 22.06.2021
J0082515863
Product specificaties
Merk: | Jung |
Categorie: | Stopcontact |
Model: | 521ZNAUF |
Materiaal behuizing: | Kunststof |
Aantal per verpakking: | 1 stuk(s) |
Bedrijfstemperatuur (T-T): | -5 - 40 °C |
Stopcontact type: | Type F |
Frequentieclassificatie: | 50/60 Hz |
Heb je hulp nodig?
Als je hulp nodig hebt met Jung 521ZNAUF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Stopcontact Jung
15 Mei 2025
15 Mei 2025
5 Juli 2024
Handleiding Stopcontact
- Atlona
- Manhattan
- Pancontrol
- Kogan
- Schwaiger
- Philips
- InLine
- AVM
- Perel
- Asus
- Vivanco
- Busch-Jaeger
- AV:link
- PS Audio
- Crestron
Nieuwste handleidingen voor Stopcontact
16 Juni 2025
11 Juni 2025
11 Juni 2025
10 Juni 2025
10 Juni 2025
13 Mei 2025
13 Mei 2025
12 Mei 2025
2 Mei 2025