Ivation IVA20PDEHU Handleiding
Ivation
Luchtbevochtiger
IVA20PDEHU
Bekijk gratis de handleiding van Ivation IVA20PDEHU (5 pagina’s), behorend tot de categorie Luchtbevochtiger. Deze gids werd als nuttig beoordeeld door 3 mensen en kreeg gemiddeld 4.5 sterren uit 2 reviews. Heb je een vraag over Ivation IVA20PDEHU of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/5

11 Pint Smart-Touch
Dehumidifier
User Guide
IVA20PDEHU
Thank you for purchasing the Ivation® 11 Pint Smart-Touch Dehumidifier. This User
Guide is intended to provide you with guidelines to ensure that operation of this product
is safe and does not pose risk to the user. Any use that does not conform to the guidelines
described in this User Guide may void the limited warranty.
Please read all directions before using the product and retain this guide for reference. This product is intended for household use only.
This product is covered by a limited one-year warranty. Coverage is subject to limits and exclusions. See warranty for details.
Box Contents
Dehumidifier
User guide
Safety Precautions
• Install the unit on flat and hard floor to diminish vibration or noise.
• Never immerse the unit in water or other liquids.
• Never operate the unit if the cable or other connector is damaged, or something abnormal may happen, please call customer
service for help.
• Disconnect the unit from power supply when it is not in use, or before relocating or cleaning it.
• Operate the unit only at the voltage specified.
• The unit is for indoor use only. Don’t use it for other purpose.
• Do not put heavy objects on the appliance.
• Do not tip the unit to any side as spilt water could damage the appliance.
• Never insert any object into the unit body to avoid any hazard or unit failure.
• Do not put the unit close to heat-generating devices or near flammable and dangerous materials.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order
to avoid a hazard.
• The appliance must be positioned so that the plug is accessible.
• The appliance should be installed in accordance with national wiring regulations.
• The ambient temperature range for the appliance is 41°F–95°F (5°C–35°C).
• Don’t try to repair, dismantle or remold the appliance, or it may become damaged. Even changing the power cord should be done
by special qualified person.
1
s

Parts
A. Touch panel
B. Top air outlet
C. Side air inlet
D. Side panel
E. Purify component
F. Turbofan
G. Motor
H. Condenser
I. Evaporator
J. Temperature and humidity sensor
K. Compressor
L. Float
M. Reservoir
N. Filter
O. Back air inlet
Control Panel
A. Ion
B. Timer
C. Reservoir full indicator
D. Power
E. Continuous mode indicator
F. Humidity setting
G. Fan speed
2
A
B
C
E
D
F
G
H
I
J
N
O
K
L
M
A
B
D
E
F
G
C

3
Operation
Power:
1. Press the POWER key to turn the unit on.
a. The dehumidifier will automatically enter continuous mode, and the CONT icon will glow red on the control panel.
b. The fan speed will automatically be set to high, and the SPEED icon will glow red on the control panel.
2. Press the power key again to turn the unit off. The fan will continue running for 10 seconds before powering off.
NOTE 1: When plugged in, the control panel will glow blue.
NOTE 2: When operating, the control panel icons will glow red.
Humidity settings:
1. Press the HUM SET key to exit continuous mode and enter smart mode.
2. Each press of the key will increase the humidity level by 5% from 40%–80%. When the indoor humidity is lower than the set
humidity, the machine would stop automatically.
3. 5 seconds after the humidity is set, the room’s current humidity will be displayed on the control panel.
4. Press and hold the key for 3 seconds to view the current temperature.
NOTE 1: The default humidity level is 60%.
NOTE 2: If the humidity displays as “– –%”, the system is currently in continuous mode.
Timer:
1. Press the TIMER button to set the 24 hour timer.
2. Each press will add 1 hour to the timer, up to 24 hours.
3. To turn off the timer, press the TIMER button until the displayed time is “– –”
NOTE: When the timer is set, the TIMER icon will glow blue.
Fan Speed:
1. Press the SPEED button to switch the fan between high and low speed.
NOTE 1: When high speed is selected, the SPEED icon will glow red.
NOTE 2: When low speed is selected, the SPEED icon will glow blue.
Ion:
1. Press this button to activate the ion feature.
2. This feature can be used independently of the dehumidifying feature.
NOTE: When the ionizer is on, the ION icon will glow blue.
Status codes
LO: the current humidity is below 20%
HI: the current humidity is above 95%
Product specificaties
Merk: | Ivation |
Categorie: | Luchtbevochtiger |
Model: | IVA20PDEHU |
Heb je hulp nodig?
Als je hulp nodig hebt met Ivation IVA20PDEHU stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Luchtbevochtiger Ivation
11 Augustus 2025
11 Augustus 2025
11 Augustus 2025
11 Augustus 2025
Handleiding Luchtbevochtiger
- Suntec
- Winland
- Electrolux
- Trotec
- Arovec
- Orbegozo
- Vornado
- Zojirushi
- Crestron
- Alberello
- Vitek
- Wilfa
- Noveen
- Onlili
- Brune
Nieuwste handleidingen voor Luchtbevochtiger
8 Augustus 2025
8 Augustus 2025
8 Augustus 2025
8 Augustus 2025
5 Augustus 2025
5 Augustus 2025
5 Augustus 2025
5 Augustus 2025
5 Augustus 2025
5 Augustus 2025