Intermatic T1976R Handleiding
Intermatic
Schakelaar
T1976R
Bekijk gratis de handleiding van Intermatic T1976R (1 pagina’s), behorend tot de categorie Schakelaar. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 4.4 sterren uit 3.5 reviews. Heb je een vraag over Intermatic T1976R of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/1

Model T1976R
PROGRAM TIME SWITCH WITH “SKIPPER
®
”
IN RAINPROOF ENCLOSURE
FOR UP TO 48 TIMING OPERATIONS
ON 24 HOUR SCHEDULE
SINGLE POLE DOUBLE THROW
SWITCH RATING: 20 AMP. 125-480 VOLTS A.C. 1/2 HP-125V 1 HP-250V.
WIRING INSTRUCTIONS
This Time Switch can be wired to control two circuits as Single Pole Double throw,
or to control one circuit as Single Pole Single Throw. Either normally open (NO) or
normally closed (NC). To wire switch see wiring diagram above.
PROGRAMMING INSTRUCTIONS
TO PROGRAM TIME SWITCH, Depress tripper(s) into dial at desired time(s)
operation(s) is/are required.
• ON TIME: First tripper turns on the load for 16-20 minutes. Each additional
tripper will lengthen the on time by 15 minutes. If skipping of selected days is
desired, the skipper tripper (silver color) should be used to initiate the first oper-
ation of the daily program, provided that there is at least 3 hours between the
last operation of the previous day and the first operation of the present day.
• OFF TIME: First tripper in raised position turns off the load for 10-14 minutes.
Each additional space will lengthen the off time by 15 minutes.
SET TIME-OF-DAY: Turn dial in clockwise direction only and align the exact
time-of-day (the time now when switch is being put into operation) to the “TIME”
arrow on insulator.
CHECK SKIPPER WHEEL If switch is to function seven days a week, pull all
pins, in skipper wheel up to “OUT” position. Otherwise depress pin(s) in skipper
wheel for day(s) automatic operation is not required.
• If, after the dial is set to the correct time of day, and the skipper tripper (silver
color) has not yet passed the skipper wheel, turn wheel counter clockwise so
that the previous day is opposite the “DAY” arrow.
• If the skipper tripper has already passed the skipper wheel, set the correct day
opposite the “DAY” arrow.
CLOCK
MOTOR
SUPPLY
NORMALLY CLOSED CIRCUIT
NORMALLY OPEN CIRCUIT
FIG. 1 WIRING DIAGRAM
CLOCK
COM.
N.C.N.O.
N.C.
LOAD
NO.
LOAD
1.
2.
3.
OPERATING INSTRUCTIONS
TO CONTROL LOADS MANUALLY, Move manual lever (See Figure 1) up. This
lever will close normally open circuit and open the normally closed circuit. To return,
to automatic control, move lever back to its original position .
IN CASE OF POWER FAILURE, reset dial. See step (2) of programming instruc-
tions.
TO REMOVE MECHANISM FROM CASE, Disconnect electricity and all wiring.
Depress retainer spring at upper left, then grasp dial and pull mechanism out.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
154--00916
CLOCK MOTOR: 208- 277 VOLTS - 60 HZ.
CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO ORDER
REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.
LR3730
TIME
DIAL
INSULATOR
MANUAL
LEVER
CAP
NUTS
SKIPPER
DAY
TIME
Product specificaties
Merk: | Intermatic |
Categorie: | Schakelaar |
Model: | T1976R |
Heb je hulp nodig?
Als je hulp nodig hebt met Intermatic T1976R stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Schakelaar Intermatic
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
Handleiding Schakelaar
- Intelix
- Cudy
- Smartwares
- Omnitronic
- Emerson
- Nedis
- Fantini Cosmi
- Adviti
- KVM-TEC
- Micro Connect
- Kopp
- Monoprice
- Merlin Gerin
- Juniper
- Wago
Nieuwste handleidingen voor Schakelaar
15 Juni 2025
15 Juni 2025
10 Juni 2025
9 Juni 2025
8 Juni 2025
8 Juni 2025
8 Juni 2025
8 Juni 2025
8 Juni 2025
8 Juni 2025