MODEL:T1905P
PROGRAM TIME SWITCH
IN TYPE 3R DUSTPROOF/RAINPROOF ENCLOSURE
SUITABLE FOR POOL EQUIPMENT CONTROL IF
INSTALLED 5 FT.
OR MORE FROM EDGE OF POOL
FOR UP TO 48 TIMING OPERATIONS
SWITCH RATING: 20 AMP. 125-480 VOLTS A.C. 1/2 HP-125V 1 HP-250V.
WIRING INSTRUCTIONS
diagram above.
TO PROGRAM TIME SWITCH,Depress tripper(s) into dial at desired
time(s) operation(s) is/are required.
•ON TIME: First tripper turns on the load for 16-20 minutes. Each
additional tripper will lengthen the on time by 15 minutes.
•OFF TIME: First tripper in raised position turns off the load for
10-14 minutes.Each additional space will lengthen the of time by 15
minutes.
SET TIME-OF-DAY: Turn dial in clockwise direction only and align
the exact time-of-day (the time now when switch is being put into
operation) to the “TIME” arrow on insulator.
TIME
DIAL
INSULATOR
MANUAL
LEVER
CAP
NUTS
CLOCK
MOTOR
SUPPLY
NORMALLY CLOSED CIRCUIT
NORMALLY OPEN CIRCUIT
FIG. 1 WIRING DIAGRAM
CLOCK
COM.
N.C.
N.O.
N.C.
LOAD
NO.
LOAD
1.
2.
OPERATING INSTRUCTIONS
TO CONTROL LOADS MANUALLY,Move manual lever (See Figure
1) up. This lever will close normally open circuit and open the normally
closed circuit. To return, to automatic control, move lever back to its
original position .
IN CASE OF POWER FAILURE, reset dial. See step (2) of programming
instructions.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158TS10969
CLOCK MOTOR: 125 VOLTS - 60 HZ.
CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO ORDER
REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.
LR3730