Intergas Compact HRE 18 SB Handleiding

Intergas CV Ketel Compact HRE 18 SB

Lees hieronder de đź“– handleiding in het Nederlandse voor Intergas Compact HRE 18 SB (4 pagina's) in de categorie CV Ketel. Deze handleiding was nuttig voor 74 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
1
Compact HRE
18 SB
24 SB
30 SB
40 SB
Operating Instructions
Installation of the appliance may only be carried out by an installer/competent person.
Please ask your installer to instruct you on how to fill and bleed the appliance and the
installation and on their operation. Strictly abide by all the instructions and warnings.
Always use the appliance in accordance with the Operating Instructions. It is forbidden to
interfere with a sealed component.
CONTENTS
1 Operation of the appliance 2
1.1 Operation of the central heating ................................................................. 2
1.2 Operation of domestic hot water supply (in combination with an indirectly
heated hot water storage cylinder ............................................................. 2
2 Operation and display read- 2-3 out
2.1 Operating mode on the service display 3 ......................................................
2.2 Changing the settings of the various functions ........................................... 3
3 Start- 3 up
4 Faults 3- 4
5 Filling and bleeding appliance and installation 4
5.1 Central heating system ............................................................................... 4
5.3 Frost protection ........................................................................................... 4
6 Maintenance 4
© 2012 Intergas Heating Ltd Subject to change.
2
Intergas Heating Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic
heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and
promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk.
Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the
product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a
commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales).
All Installations must be notified to Local Aerea Building Control either directly or through a Competent Persons Scheme. A Building Regulations
Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist.
This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service
Record on the Benchmark Checklist after each service. The Benchmark cheklist may be required in the event of any warrranty work and as supporting
documentation relating to home improvements in the optional documents section of the Home Information Pack.
1 OPERATION OF THE APPLIANCE
The purpose of the Intergas Compact HRE SB wall mounted gas fired boiler is to heat water and to supply it to the central heating (CH)
system and when an indirectly heated domestic hot water storage cylinder is installed, apply heat to the domestic hot water (DHW)
installation.
The appliance is fitted with a modulating control. This means that the power is adjusted in line with the required heat. The boiler
controller responds to each call for heat from the heating or the DHW system by igniting the burner and monitoring the flame.
1.1 Operation of the central heating
The call for heat arises as a result of the room temperature being lower than the temperature set on the room thermostat. If at that time
the appliance does not have a call for DHW, the appliance comes on in central heating mode. The central heating temperature control
modulates on the basis of the set central heating supply temperature. This means that when the desired central heating supply
temperature is approached the appliance adjusts the power.
The pump for the central heating has a post purge period of 1 minute. The post purge period may be changed if desired. The pump runs
automatically for 10 seconds once every 24 hours to prevent blocking.
1.2 Operation of domestic hot water supply
By connecting the Compact HRE SB to a DHW storage cylinder the DHW circuit can be heated. The built-in regulation ensures that the
DHW demand takes preference over a CH demand. During delivery of hot tap water no heat is supplied by the appliance to the central
heating system.
2 OPERATION AND DISPLAY READ-OUT
Read-out
Operation
1
On / off
A
On / Off button
2
CH operation or setting maximum CH temperature
B
DHW / CH button, for setting desired temperature
3
DHW operation or setting DHW temperature
C
- button
4
Desired temperature of CH or DHW in °C / CH water pressure (bar) / Fault code/ Time
D
+ button
5
Clock “on” CH enabled
E
Clock function setting
6
Clock “off” CH disabled
F
DHW comfort function off/eco/on (not applicable for Compact HRE SB)
7
DHW comfort function eco (not applicable for Compact HRE SB)
G
Service button
8
DHW comfort function on ((not applicable for Compact HRE SB)
H
Reset button
9
Operating code
10
Flashes to indicate fault
3
2.1 Operating mode on the service display:
Ventilate
Ignite
CH mode
DHW mode
Heat up appliance on (not applicable for Compact HRE SB)
Note: When the red LED above the reset key flashes a fault has occurred. A fault code will then appear on the temperature/clock display.
2.2 Changing the settings of the various functions
Keeping the key pressed for 2 seconds takes you to the user settings menu (LED at display starts to flash). and the
Then each time you press the key a different function LED will start to flash. The value of the function can be set using the
and keys. The value set is displayed on the display.
ď‚· The reset key closes the settings menu and stores the changes.
ď‚· If no key is pressed for 30 seconds, the settings menu is automatically closed and the changes are stored.
ď‚· The on/off key closes the settings menu without storing the changes.
ď‚· The button restores the default setting for the switch moments (hold for 5 seconds).
ď‚· By pressing the or keys the clock can be set and the switch moments can be defined.
ď‚· By pressing the s can be programmed in which the CH is on (switch moments 1 to 4). button 2 time block
ď‚· By pressing the button the new times will be stored in the boiler controller. In the display appears [P] for a short period.
ď‚· Pressing the ditional functions can be activated: button for less than 1 second the following ad
1. t-on (temporary on), the boiler will respond on every CH demand from the room thermostat until the next switch moment.
2. c-on (continuous on), the boiler will respond on every CH demand from the room thermostat without any time limit.
3. OFF, the boiler will not respond on any CH demand from the room thermostat.
. Can be set between 30°C and 90°C (standard setting 80°C). The maximum CH supply temperature
Low setting for moderately cold weather, high setting for colder weather.
DHW temperature. The temperature in the DHW storage cylinder can be set, if it is connected to an external sensor,
between 40°C and 65°C (standard setting 60°C). To prevent the growth of legionella it is advised not to set the DHW
temperature below 60°C.
All other alterations of settings of the boiler may only be carried out by your installer.
3 START- UP
Once the appliance has been connected to water, gas and electricity supplies and
checked by an authorised installer, the appliance can be started.
Please check the following points:
ď‚· The central heating system and domestic hot water system must be well filled and bled.
ď‚· The appliance must be switched off (Horizontal dash on service display, other LEDs off).
ď‚· The water pressure in the central heating system must be between 1 and 2 bar (Shown on the temperature display).
Never switch the appliance on if the appliance, the CH system and the DHW system have not been completely filled and bled.
ď‚· The room thermostat must be set below the temperature in the room.
ď‚· The gas tap must be open.
ď‚· Switch the appliance on with the on/off key in the display (The LED lights up, and the service display goes out). The appliance
may now heat up for purposes of the DHW system until the heat exchanger reaches the set temperature.
 Set the clock and the switch moments. If the boiler is in a time block that CH is not active the boiler must be set in c-on (see §2.2).
ď‚· Set the room thermostat higher than the actual room temperature. The appliance will fire for purposes of the CH system.
4 FAULTS
If the following simple appliance faults occur, they can be resolved as follows. In the case of repeated occurrence or other faults
always notify your installer.
1. The CH system does not heat up or does not become sufficiently warm:
ď‚· Increase the temperature setting at the room thermostat.
ď‚· Open the radiator valves.
 Increase the CH water temperature setting using the key on the operating panel (see §2 and the and ).
ď‚· Bleed the appliance and installation and check the CH water pressure.


Product specificaties

Merk: Intergas
Categorie: CV Ketel
Model: Compact HRE 18 SB

Heb je hulp nodig?

Als je hulp nodig hebt met Intergas Compact HRE 18 SB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding CV Ketel Intergas

Handleiding CV Ketel

Nieuwste handleidingen voor CV Ketel