Pagina 1/24
HOB
PI 640 AT EX
Contents
Installation, 2-6
Positioning
Electrical connection
Gas connection
Data plate
Burner and nozzle specifications
Description of the appliance, 7
Overall view
Start-up and use, 8
Practical advice on using the burners
Precautions and tips, 9
General safety
Disposal
Maintenance and care, 10
Switching the appliance off
Cleaning the appliance
Gas tap maintenance
Troubleshooting, 11
Operating Instructions
Français, 12English,1
FR
GB
GB
2
GB
! Before operating your new appliance please read
this instruction booklet carefully. It contains important
information for safe use, installation and care of the
appliance.
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of
the appliance.
Positioning
! Keep packaging material out of the reach of
children. It can become a choking or suffocation
hazard (see Precautions and tips).
! The appliance must be installed by a qualified
professional according to the instructions provided.
Incorrect installation may cause harm to people and
animals or may damage property.
î‚• The room must be equipped with an air extraction
system that expels any combustion fumes. This
may consist of a hood or an electric fan that
automatically starts each time the appliance is
switched on.
î‚• The room must also allow proper air circulation, as
air is needed for combustion to occur normally. The
flow of air must not be less than 2 m3/h per kW of
installed power.
The air circulation system may
take air directly from the
outside by means of a pipe
with an inner cross section of
at least 100 cm2; the opening
must not be vulnerable to any
type of blockages.
The system can also provide
the air needed for combustion
indirectly, i.e. from adjacent
rooms fitted with air circulation
tubes as described above.
However, these rooms must not
be communal rooms,
bedrooms or rooms that may
present a fire hazard.
î‚• Liquid petroleum gas sinks to the floor as it is
heavier than air. Therefore, rooms containing LPG
cylinders must also be equipped with vents to allow
gas to escape in the event of a leak. As a result
LPG cylinders, whether partially or completely full,
must not be installed or stored in rooms or storage
areas that are below ground level (cellars, etc.). It is
advisable to keep only the cylinder being used in
the room, positioned so that it is not subject to heat
produced by external sources (ovens, fireplaces,
stoves, etc. ) which could raise the temperature of
the cylinder above 50°C.
Fitting the appliance
Gas and mixed hobs are manufactured with type X
degree protection against overheating. The following
precautions must be taken when installing the hob:
î‚• Kitchen cabinets adjacent to the appliance and
taller than the top of the hob must be at least 600
mm from the edge of the hob.
î‚• Hoods must be installed according to their relative
installation instruction manuals and at a minimum
distance of 650 mm from the hob.
î‚• Place the wall cabinets adjacent to the hood at a
minimum height of 420 mm from the hob (see
figure).
If the hob is installed beneath a
wall cabinet, the latter must be
situated at a minimum of 700
mm above the hob (see figure).
î‚• The installation cavity should have the dimensions
indicated in the figure.
Installation
Enlarging the ventilation slot
between window and floor.
A j cd a ent
R moo
R moo to be
Vented
A
Examples of ventilation holes
for comburant air.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
Directly to
the utsideO
600mm min.
540mm min.
700mm min.
GB
3
Fastening hooks are provided, allowing you to
fasten the hob to tops that are between 20 and 40
mm thick. To ensure the hob is securely fastened to
the top, we recommend you use all the hooks
provided.
555 mm
55 mm
475 mm
Hook fastening diagram
20
30
Hooking position Hooking position
for top H=20 mm for top H=30 mm
Front
40
Hooking position Back
for top H=40 mm
! Use the hooks contained in the î‚“accessory packî‚”
î‚• Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This
must be placed at a minimum distance of 20 mm
from the lower part of the hob.
Where a hob is installed above an oven without a
forced ventilation cooling system, adequate ventilation
must be provided inside the cabinet by means of air
holes through which air can pass (see figure).
! The hob can only be installed above built-in ovens
with a cooling ventilation system.
Installation of Built-in Cooktops on a CYLINDER
COMPARTMENT
The opening of this compartment have to permit the
easy introduction and removal of the cylinder. The
dimension of the opening and of the inside of the
compartment shall be at least large enough to
accommodate the cylinders (with regulator fitted)
which are the most commonly used in the country.
The total area of the openings in the upper part shall
be at least 1/100 of the floor area of the compartment.
The total area of the openings of the base shall be at
least 1/50 of the floor area of the compartment.
The cylinder support:
î‚• shall have sufficient mechanical strength.
î‚• shall not let the cylinder rest directly in the ground.
î‚• shall not sill higher than the base on which the
cylinder rests.
The cylinder tap have to be readily accessible.
Overflow of liquid from pans of the hotplate shall not
fall onto cylinder or its accessories.
The flexible tube shall not be in contact with sharp
edges.
No internal communication shall exist between the
cylinder compartment and the different parts of the
appliance where burners are placed.
The ventilation openings of the compartment cannot
be obstructed when the appliance is placed in
position.
Electrical connection
Hobs equipped with a three-pole power supply cable
are designed to operate with alternating current at the
voltage and frequency indicated on the data plate
(this is located on the lower part of the appliance). The
earth wire in the cable has a green and yellow cover.
If the appliance is to be installed above a built-in
electric oven, the electrical connection of the hob and


Product specificaties

Merk: Indesit
Categorie: Fornuis
Model: PI 640 AT (IX) EX

Heb je hulp nodig?

Als je hulp nodig hebt met Indesit PI 640 AT (IX) EX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis Indesit

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis