IFM ZZ0692 Handleiding
Pagina's 26 Niet gecategoriseerd
Bekijk de handleiding van IFM ZZ0692 gratis online of download de PDF. Deze handleiding is 2 keer bekeken. Vraag over dit model? Stel een vraag

Operating instructions
Position sensor for valve actuators
MVQ201
ZZ0628
ZZ0629
ZZ0630
ZZ0691
ZZ0692
© ifm electronic gmbh • 11590808 / 00 01 / 2026 • en-GB

MVQ201 ZZ0628 ZZ0629 ZZ0630 ZZ0691 ZZ0692Position sensor for valve actuators
2© ifm electronic gmbh 11590808 / 00 01 / 2026
Contents
1Preliminary note..............................................................................................................................4
1.1Symbols used.......................................................................................................................4
1.2Warnings..............................................................................................................................4
2Safety instructions..........................................................................................................................5
3Intended use..................................................................................................................................6
3.1Restriction of the application area.........................................................................................6
4Items supplied................................................................................................................................7
5Function.........................................................................................................................................8
5.1Position feedback.................................................................................................................8
5.2Switching functions..............................................................................................................8
5.3Overview of sensing ranges..................................................................................................9
5.3.1Tolerance range...........................................................................................................9
5.3.2Hysteresis....................................................................................................................9
5.3.3Leak warning range......................................................................................................10
5.4Timeout................................................................................................................................10
5.5Opening and closing times...................................................................................................10
5.6Communication interruption (watchdog)...............................................................................10
5.7Teach function.....................................................................................................................10
5.7.1Auto teach...................................................................................................................10
5.7.2PLC teach....................................................................................................................10
5.7.3Manual teaching via the teach button...........................................................................11
5.7.3.1Switch point SP1 - valve open............................................................................11
5.7.3.2Switch point SP2 - valve closed..........................................................................11
5.7.3.3Swaping switch points SP1 and SP2..................................................................11
5.7.3.4Locking the unit.................................................................................................12
5.7.3.5Unlocking the device..........................................................................................12
5.8Diagnostics..........................................................................................................................12
5.8.1Movement times...........................................................................................................12
5.8.2Switching cycles counters............................................................................................12
5.8.3Target monitoring.........................................................................................................12
5.8.4Operating hours counter..............................................................................................13
5.8.5Switch-on operations...................................................................................................13
5.8.6Internal temperature.....................................................................................................13
5.8.7BLOBs.........................................................................................................................13
5.9IO-Link.................................................................................................................................13
6Installation......................................................................................................................................15
6.1General notes about compressed air....................................................................................16
6.2Specification of the compressed air purity.............................................................................16
6.3Installation of the solenoid valve............................................................................................16
6.3.1Pneumatic switching symbols of the solenoid valves supplied to DIN ISO 1219............17
7Electrical connection......................................................................................................................18
7.1Output configuration of the solenoid valves in SIO mode.......................................................19
8Operating and display elements......................................................................................................20
8.1Status LEDs.........................................................................................................................20
8.2LED ring...............................................................................................................................20
9Parameter setting...........................................................................................................................21
9.1Adjustable parameters and system commands.....................................................................21
10Operation.......................................................................................................................................23
11Troubleshooting..............................................................................................................................24
11.1Error messages....................................................................................................................24
11.2Diagnostic messages...........................................................................................................24

Position sensor for valve actuatorsMVQ201 ZZ0628 ZZ0629 ZZ0630 ZZ0691 ZZ0692
© ifm electronic gmbh 11590808 / 00 01 / 20263
11.3BLOBS.................................................................................................................................24
11.3.1Opening price / Closing price BLOB.............................................................................25
11.3.2Opening time history / Closing time history BLOB.........................................................25
12Maintenance, repair and disposal...................................................................................................26
Product specificaties
| Merk: | IFM |
| Categorie: | Niet gecategoriseerd |
| Model: | ZZ0692 |
Heb je hulp nodig?
Als je hulp nodig hebt met IFM ZZ0692 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden