Bekijk gratis de handleiding van IFM VTV12A (5 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 21 mensen en kreeg gemiddeld 4.3 sterren uit 11 reviews. Heb je een vraag over IFM VTV12A of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/5

Operating instructions
Vibration transmitter
VTV12A
80000575/00 04/2013
UK

2
Symbols used
►Instructions
Important note
Non-compliance can result in malfunction or interference.
1 Safety instructions
• Please read the product description prior to set-up of the unit. Ensure that the
product is suitable for your application without any restrictions.
• The unit complies with the relevant regulations and EU directives.
• Improper or non-intended use may lead to malfunctions of the unit or to
unwanted effects in your application.
• That is why installation, electrical connection, set-up, operation and
maintenance of the unit must only be carried out by qualified personnel
authorised by the machine operator.
• Pleaseadheretothenotesonsafeuseinhazardousareas:→operating
instructions (Ex protection related part) for vibration sensors according to the
EU directive 94/9/EC annex VIII (ATEX) group II, equipment category 3G / 3D.
• If no operating instructions (Ex protection related part) or EC declaration of
conformity is supplied with this product in the language of the EU user country,
these can be requested from your dealer (see delivery note) or manufacturer
(see cover sheet / back).
2 Functions and features
The vibration transmitter detects the vibration in the system (measured / evaluated
physical unit = vibration velocity). This is converted into an analogue signal at the
current output.

3
UK
3 Installation
►Mount only in a thick housing wall
(e.g. transport thread).
►Ensure that the signal direction is
correct.
►Ensure a safe vibration
transmission and allow no elastic
intermediate layers.
►Select either the ¼"-28 UNF / M8
(2) or the ¼"-28 UNF (3) threaded
adapter and insert into the unit (1).
Threaded adapters are supplied.
►Tighten using a 3 mm Allen key.
Tightening torque 8 Nm.
►Drill and tap a hole at the mounting
location:
- M8 hole / depth min. 10 mm for
threaded adapter ¼"-28 UNF/ M8.
- Or ¼"-UNF hole / depth min.
13 mm for threaded adapter
¼"-28 UNF.
►Tighten the unit with a tightening torque of 8 Nm.
4 Electrical connection
The unit must be connected by a qualified electrician. The national and
international regulations for the installation of electrical equipment must be
adhered to.
M12
4
12
3
L+
L
1
2
Pin 1: L+ (9.6...32 V DC)
Pin 2: 4...20 mA
Product specificaties
Merk: | IFM |
Categorie: | Niet gecategoriseerd |
Model: | VTV12A |
Heb je hulp nodig?
Als je hulp nodig hebt met IFM VTV12A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd IFM
1 Juli 2025
30 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
23 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
Handleiding Niet gecategoriseerd
- Sven
- Scosche
- Xblitz
- Nyko
- Eminent
- ESI
- Milectric
- OSEE
- Naim
- Morningstar
- Weil
- Little Tikes
- Qualcast
- AddLiving
- XGIMI
Nieuwste handleidingen voor Niet gecategoriseerd
1 Juli 2025
1 Juli 2025
1 Juli 2025
1 Juli 2025
1 Juli 2025
1 Juli 2025
1 Juli 2025
1 Juli 2025
1 Juli 2025
1 Juli 2025