Bekijk gratis de handleiding van IFM SF3405 (5 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 15 mensen en kreeg gemiddeld 4.4 sterren uit 8 reviews. Heb je een vraag over IFM SF3405 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/5
Installation Instructions
Flow sensor
SF ceramics
701777 / 03 06 / 2011
UK
2
1 Functions and features
In conjunction with the VS3000 control monitor the flow sensor monitors flows
in liquids. The sensor / control monitor combination senses whether there is a
preset flow rate (= medium flowing) or not (= medium not flowing) and provides a
switched signal.
2 Installation
The sensor tip must be completely immersed in the medium.
In the case of horizontal pipes mount the unit from the side, if possible (fig. 1).
- When the unit is to be mounted at the bottom of the pipe, it should be free
from deposits.
- When the unit is to be mounted at the top of the pipe, it should be completely
filled with the medium to be monitored.
In the case of vertical pipes mount the unit in a place where the medium flows
upwards (fig. 2).
A
B
1
A
B
2
A: mounting bush; B: packing washer
for units with thread
G¼ G½
Mounting bush (A) 15 mm 33 mm
Max. tightening torque 8 Nm 30 Nm
The thread of the mounting bush must be clean, undamaged and comply
with the standard (pipe thread to DIN ISO 228).
For sealing use the supplied PTFE packing washer.
3
UK
To avoid malfunction a minimum distance between the flow monitor and bends,
valves or such like must be observed. Min. 5 x pipe diameter upstream (A), min.
3 x pipe diameter downstream (B).
D
A
B
min.
5 x D
min.
3 x D
3
3 Electrical connection
The unit must only be connected by an electrician.
The national and international regulations for the installation of electrical
equipment must be observed.
Connection to control monitor VS3000; voltage supply to EN50178, SELV,
PELV.
For units with cULus approval and the scope of validity cULus:
The device shall be supplied from an isolating transformer having a sec-
ondary Listed fuse rated either
a) max 5 amps for voltages 0~20 Vrms (0~28.3 Vp) or
b) 100/Vp for voltages of 20~30 Vrms (28.3~42.4 Vp).


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: SF3405

Heb je hulp nodig?

Als je hulp nodig hebt met IFM SF3405 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM AL1590 Handleiding

3 September 2025
IFM

IFM AL1591 Handleiding

3 September 2025
IFM

IFM QCM110 Handleiding

2 September 2025
IFM

IFM VMB301 Handleiding

27 Augustus 2025
IFM

IFM PG1709 Handleiding

15 Augustus 2025
IFM

IFM EVC875 Handleiding

15 Augustus 2025
IFM

IFM PG1743 Handleiding

15 Augustus 2025
IFM

IFM EVM045 Handleiding

15 Augustus 2025
IFM

IFM DTI921 Handleiding

15 Augustus 2025
IFM

IFM PG1708 Handleiding

14 Augustus 2025

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd