IFM PE3003 Handleiding
IFM
Niet gecategoriseerd
PE3003
Bekijk gratis de handleiding van IFM PE3003 (17 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 18 mensen en kreeg gemiddeld 4.3 sterren uit 9.5 reviews. Heb je een vraag over IFM PE3003 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/17

Operating instructions
Pressure sensor
PE30xx
704884 / 00 08 / 2010
UK

2
Contents
1 Preliminary note3
1 Symbols used 3
2 Safety instructions 3
3 Functions and features 4
4 Function 5
41 Processing of the measured signals 5
42 Switching function 5
43 Analogue function 6
5 Installation 6
6 Electrical connection6
7 Operating and display elements 7
8 Menu8
81 Menu structure 8
82 Explanation of the menu 9
9 Parameter setting 10
91 Parameter setting general 10
92 Configuring the display (optional) 12
93 Configuration of output 1 12
931 Setting the output function 12
932 Setting the switching limits 12
94 Configuration of output 2 12
95 User settings (optional) 12
951 Setting the delay time for OUT1 12
952 Setting the damping for OUT1 13
96 Service functions 13
961 Reading the min/max values for the system pressure 13
10 Operation 13
101 Read the set parameter values 13
102 Fault indication 13
11 Scale drawing 14
12 Technical data 14
121 Setting ranges 16
13 Factory setting 17

3
UK
1 Preliminary note
1. Symbols used
►Instruction
> Reaction, result
[…] Designation of buttons, switches or indications
→Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
2 Safety instructions
• Read this document before installing the unit. Ensure that the product is suit-
able for your application without any restrictions.
• Non-adherence to the operating instructions or technical data can lead to
personal injury and/or damage to property.
• In all applications check compliance of the product materials ( chapter 12 →
Technical data) with the media to be measured.
• Use in gases at pressures > 25 bar only after contacting the manufacturer ifm
For units with cULus approval and the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated as noted in the following table.
Overcurrent protection
Control-circuit wire size Maximum protective device rating
Ampere
AWG (mm2)
26 (0.13) 1
24 (0.20) 2
22 (0.32) 3
20 (0.52) 5
18 (0.82) 7
16 (1.3) 10
The Sensor shall be connected only by using any R/C (CYJV2) cord, having suit-
able ratings.
Product specificaties
Merk: | IFM |
Categorie: | Niet gecategoriseerd |
Model: | PE3003 |
Heb je hulp nodig?
Als je hulp nodig hebt met IFM PE3003 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd IFM
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
23 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
Handleiding Niet gecategoriseerd
- Browin
- Deltaco Gaming
- Ordex
- Edge
- Cambo
- Helios Preisser
- Altrad
- View Quest
- Brinno
- Maglite
- Rexel
- AMC
- Tandberg Data
- GANA
- Black Diamond
Nieuwste handleidingen voor Niet gecategoriseerd
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025