Bekijk gratis de handleiding van IFM OGT102 (5 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 21 mensen en kreeg gemiddeld 4.8 sterren uit 11 reviews. Heb je een vraag over IFM OGT102 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/5
Operating instructions
Diffuse reflection sensor
OGT1xx
UK
UK
UK
UK
UK
OGT100 / 00 11 / 2009
2
1 Preliminary note
1.1 Symbols used
Instruction
> Reaction, result
Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
2 Functions and features
The diffuse reflection sensor detects objects and materials without contact and
indicates their presence by a switching signal.
Range: packaging or data sheet.
3 Installation
LED1:
setting potentiometer2:
Align the diffuse reflection sensor to the object to be detected.
Secure it to a bracket.
4 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electri-
cal equipment must be adhered to.
Ensure a voltage supply according to EN 50178, SELV, PELV.
Disconnect power.
Connect the unit as follows:
3
UK
DC PNP DC NPN
L+
L
1
4
3
L+
L
1
4
3
Settings
LED1:
setting potentiometer2:
Set the setting potentiometer to the minimum range.
Position the object to be detected in the detection zone.
Increase the range until the LED lights (= minimum value; object detected).
Remove the object from the detection zone.
LED goes out. >
Increase the range until the LED lights (= maximum value; background de-
tected).
Set the range to the middle position between minimum value and maximum
value.
5 Operation
Check whether the unit operates correctly.
Dark-on switching units: the output is switched / the yellow LED is lit when no
object is detected.
Light-on switching units: the output is switched / the yellow LED is lit when an
object is detected.