Bekijk gratis de handleiding van IFM OGH700 (5 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 19 mensen en kreeg gemiddeld 3.6 sterren uit 10 reviews. Heb je een vraag over IFM OGH700 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/5
Operating instructions
Diffuse reflection sensor with
background suppression
OGH7xx
80284281 / 00 04 / 2019
UK
2
1 Preliminary note
1.1 Symbols used
Instruction
> Reaction, result
[…] Designation of pushbuttons, buttons or indications
Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
2 Safety instructions
According to the cULus approval
Caution - Use of controls or adjustments or procedures other than those specified
herein may result in hazardous radiation exposure.
Visible laser light; CLASS 1 LASER PRODUCT.
EN/IEC 60825-1 : 2007 and EN/IEC 60825-1 : 2014 complies with 21 CFR
1040 except for deviations pursuant to Laser Notice No. 50, dated June
2007
Position of the product label Additional label
3 Functions and features
The diffuse reflection sensor detects objects and materials without contact and
indicates their presence by a switching signal.
Range 20 ... 200 mm (on white paper 200 x 200 mm, 90 % remission)
3
UK
4 Installation
1: LED
2: programming buttons
Align the diffuse reflection sensor to the object to be detected.
Secure it to a bracket.
Note:
The objects to be detected are to move
transversally to the lens of the sensor.
In case of other directions of movement
it should be tested before whether safe
switching is guaranteed.
5 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of
electrical equipment must be adhered to.
Voltage supply according to EN 50178.
Disconnect power.
Connect the unit as follows:
DC PNP
pin 1 = L+ ( 10...36 V DC )
pin 3 = L-
pin 4 = load (200 mA)
(pin 2 = not connected)
DC NPN
pin 1 = L+ ( 10...36 V DC )
pin 3 = L-
pin 4 = load (200 mA)
(pin 2 = not connected)


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: OGH700

Heb je hulp nodig?

Als je hulp nodig hebt met IFM OGH700 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM AL1590 Handleiding

3 September 2025
IFM

IFM AL1591 Handleiding

3 September 2025
IFM

IFM QCM110 Handleiding

2 September 2025
IFM

IFM VMB301 Handleiding

27 Augustus 2025
IFM

IFM PG1709 Handleiding

15 Augustus 2025
IFM

IFM EVC875 Handleiding

15 Augustus 2025
IFM

IFM PG1743 Handleiding

15 Augustus 2025
IFM

IFM EVM045 Handleiding

15 Augustus 2025
IFM

IFM DTI921 Handleiding

15 Augustus 2025
IFM

IFM PG1708 Handleiding

14 Augustus 2025

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd