Operating instructions
Retro-reflective sensor
OG
701300 / 03 09 / 2005
UK
UK
UK
UK
UK
2
Function and features
In conjunction with a prismatic reflector or reflective tape the retro-reflective
sensor detects objects and materials without contact and indicates their presence
by a switched signal.
Range (r): see type label (value referred to prismatic reflector with Ø 80mm).
Electrical connection
Isolate power, then connect the unit. The device shall be supplied from
an isolating source and protected by an overcurrent device such that the
limited voltage circuit requirements in accordance with UL 508 are met.
Wiring:
L+
L
1
4
3
Installation and alignment
21
Setting button
LEDs yellow, green
Fix prismatic reflector / reflective tape in desired position. Align the photocell
towards the reflector; the light spot must hit the prismatic reflector.
Maximum range is only possible with precise alignment.
1:
2:
3
UK
NB: Commissioning
The retro-reflective sensor is supplied ready to operate (plug and play) set at the
max. sensing range. This is sufficient if the retro-reflective sensor can operate
with maximum excess gain (highest contrast). The following setting procedures
should only be necessary in less straightforward applications, for example if partly
transparent objects must be detected.
Setting of the sensitivity with stationary objects
1
Activate the programming mode of the unit.
Press for about 2s until the LEDs flash.
Yellow and green LEDs flash alternately.
The unit is in the programming mode.
2
Set the sensitivity with object.
Press once.
The yellow and green LEDs go out for approx. 1s, then flash again alternately.
3
Set the sensitivity without object.
Press once.
The yellow and green LEDs go out for approx. 1s, then the green LED is on.
The unit is in the operating mode.
You can also proceed in reverse order: first setting without the object, then with the object.


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: OG5118

Heb je hulp nodig?

Als je hulp nodig hebt met IFM OG5118 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM DP4302 Handleiding

12 April 2024
IFM

IFM EVCB02 Handleiding

11 Maart 2024
IFM

IFM EVCB03 Handleiding

11 Maart 2024
IFM

IFM EVF666 Handleiding

11 Maart 2024
IFM

IFM TM4599 Handleiding

8 Januari 2024
IFM

IFM ZB0074 Handleiding

8 Januari 2024
IFM

IFM EVF661 Handleiding

8 Januari 2024
IFM

IFM IIP201 Handleiding

7 Januari 2024
IFM

IFM DP4200 Handleiding

7 Januari 2024
IFM

IFM IIP200 Handleiding

7 Januari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd