Bekijk gratis de handleiding van IFM O4H200 (3 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 12 mensen en kreeg gemiddeld 4.8 sterren uit 6.5 reviews. Heb je een vraag over IFM O4H200 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/3
Installation Instructions
Diffuse-reflection sensor
with background suppression
O4H200
706272 / 00 11 / 2012
UK
2
Functions and features
The diffuse-reflection sensor detects objects and materials without contact and
indicates their presence by a switched signal.
Range: see type label.
Installation
Align the photocell and fasten to a mounting device.
 

The objects to be detected are to move tran-
versally to the lens of the unit. In case of other
directions of movement it should be tested before
whether safe functioning is guaranteed.
Electrical connection
Disconnect power before connecting the sensor. Connection strictly to the
indications on the type label.
3
UK
Setting of the sensitivity
 

2
1
1: LED
2: setting potentiometer sensing range
Proceed as follows:
1. Set the potentiometer to the smallest sensing range (1).
2. Place the object to be detected within the sensing range.
3. Increase the sensing range until the LED lights (= minimum value; object
detected).
4. Remove the object from the sensing range (LED goes off).
5. Increase the sensing range until the LED lights (= maximum value; background
detected).
6. Set the potentiometer to the medium position between minimum and maximum
value.
Operation
Check the safe functioning of the sensor.
• The LED lights if light is received (= object detected).
Maintenance
Keep the lens of the sensor free from soiling.
For cleaning do not use any solvents or cleaning agents which could damage the
plastic lenses.
Technical data
You can download the data sheet from the Internet address www.ifm.com if
required.