IFM IN512A Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor IFM IN512A (3 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 15 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
706181/00 04/2012
UK
Operating instructions
(Ex protection related part) for inductive sensors according to EU
directive 94/9/EC annex VIII (ATEX) group II, equipment category
3D
IN512A
2
Remarks for safe use in hazardous areas
Functions and features
• Use in hazardous areas according to the classication
II 3D
(group II, category 3D, apparatus for dust atmosphere).
The requirements of the standards EN 60079-0:2009 and EN 60079-31:2009 are met.
• Marking (see unit or technical data sheet):
II 3D Ex tc IIIC T80°C Dc IP67 X
• Permissible ambient temperature of the application (proper usage) (see unit or technical
data sheet):
-20°C 60°C≤ Ta ≤
Installation / Set-up
The units must only be installed, connected and set up by qualied staff. The qualied staff
must have knowledge of protection classes, regulations and provisions for apparatus in
hazardous areas.
Check whether the classication (see "Marking" above and marking on the unit) is suitable
for the application.
Installation remarks / Installation
• Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
• Avoid electrostatic charging on plastic units and cables.
• To avoid electrostatic charging clean the unit with a damp cloth only.
• To avoid electrostatic charging steps must be taken to ensure the equalisation of potential
of metal parts (plug housing, xing elements, protective housing, etc.).
• Do not mount the unit in the dust ow.
• Avoid dust deposits on the units.
• Protect the units and the cables efciently against damage.
• For the connections and the electrical characteristics please see the unit marking or the
technical data sheet.
• Protect the unit (plastic parts) from UV light.
3
UK
Special conditions for safe operation
• The unit (1) must only be installed in conjunction with the supplied protective housing (2).
• Use the supplied mounting plate (3) to ensure a secure t of the mounting screws (4).
2
4
3
1
1. Proximity sensor
2. Protective housing
3. Mounting plate
4. Mounting screws (supplied with the
unit).
• The cable must be rmly xed at the sensor end.
• Permissible temperature range
- -5°C, if the cable is moved during operation
- -20°C, if the cable is not moved during operation
• The housings are rated for a low mechanical risk and tested with an impact energy of 4
joules.
• The sensing face is not designed for mechanical stress. Therefore the unit must only be
operated with target pucks which exclude mechanical stress on the sensing face.
• Tightening torque of the mounting screws MA = 1 Nm (±10%).
Maintenance / Repair
The unit must not be modiî‹Šed nor can it be repaired. In case of a fault please contact the
manufacturer.
If required, the technical data sheets and EC declarations of conformity can be obtained
from the manufacturer. Indicate the article number.


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: IN512A

Heb je hulp nodig?

Als je hulp nodig hebt met IFM IN512A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM DP4302 Handleiding

12 April 2024
IFM

IFM EVCB02 Handleiding

11 Maart 2024
IFM

IFM EVCB03 Handleiding

11 Maart 2024
IFM

IFM EVF666 Handleiding

11 Maart 2024
IFM

IFM TM4599 Handleiding

8 Januari 2024
IFM

IFM ZB0074 Handleiding

8 Januari 2024
IFM

IFM EVF661 Handleiding

8 Januari 2024
IFM

IFM IIP201 Handleiding

7 Januari 2024
IFM

IFM DP4200 Handleiding

7 Januari 2024
IFM

IFM IIP200 Handleiding

7 Januari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd