Bekijk gratis de handleiding van IFM IN0131 (3 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 54 mensen en kreeg gemiddeld 4.8 sterren uit 27.5 reviews. Heb je een vraag over IFM IN0131 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/3

Installation Instructions
Dual sensor INE
IN0131
80275425/00 05/2018
UK

2
1 Preliminary note
Technical data, approvals, accessories and further information at
www.ifm.com.
1.1 Safety instructions
• Read this document before setting up the product and keep it during the entire
service life.
• The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
• Only use the product for its intended purpose (→ Functions and features).
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
• The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
• Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
• The plant manufacturer is responsible for the safety of the plant in which the
device is installed.
• If the device is used in a way that is not intended by the manufacturer, the
protection supported by the device may be impaired.
• Protect units and cables against damage.
2 Function and features
It is designed for use on pneumatic valve actuators.
3 Montage
► To reach protection rating IP67 replace the protective dust cap with a suitable
cable gland.
Recommendation: ifm article numbers E12208 and E12209.
► Before replacing the cover of the terminal chamber on the sensor ensure that the
sealing surface is clean and undamaged.
Fixing screw M3, tightening torque 0.8 Nm.

3
UK
► Fixing the sensor to an actuator:
fixing screw M5, tightening torque 1.8 Nm.
4 Electrical Connection
► Disconnect the system from power before working with it.
► The device must be connected by a qualified electrician.
► The potential of the valve supply must be identical with the sensor potential.
Miniature fuse ≤ 2A (fast acting) according to IEC 60127-2 sheet 1.
Recommendation: Check the safe functioning of the unit after a short circuit.
IN
+
IN
-
A2
A1
2 A
OUT
+
OUT
-
7
8
1
4
3
5
6
2
L1 / L+
1
1: Solenoid valve output
Product specificaties
Merk: | IFM |
Categorie: | Niet gecategoriseerd |
Model: | IN0131 |
Heb je hulp nodig?
Als je hulp nodig hebt met IFM IN0131 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd IFM
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
23 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025