Installation Instructions
Dual sensor INE
IN0131
80275425/00 05/2018
UK
2
1 Preliminary note
Technical data, approvals, accessories and further information at
www.ifm.com.
1.1 Safety instructions
• Read this document before setting up the product and keep it during the entire
service life.
• The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
• Only use the product for its intended purpose (→ Functions and features).
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
• The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
• Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
• The plant manufacturer is responsible for the safety of the plant in which the
device is installed.
• If the device is used in a way that is not intended by the manufacturer, the
protection supported by the device may be impaired.
• Protect units and cables against damage.
2 Function and features
It is designed for use on pneumatic valve actuators.
3 Montage
â–º To reach protection rating IP67 replace the protective dust cap with a suitable
cable gland.
Recommendation: ifm article numbers E12208 and E12209.
â–º Before replacing the cover of the terminal chamber on the sensor ensure that the
sealing surface is clean and undamaged.
Fixing screw M3, tightening torque 0.8 Nm.
3
UK
â–º Fixing the sensor to an actuator:
fixing screw M5, tightening torque 1.8 Nm.
4 Electrical Connection
â–º Disconnect the system from power before working with it.
â–º The device must be connected by a qualified electrician.
â–º The potential of the valve supply must be identical with the sensor potential.
Miniature fuse ≤ 2A (fast acting) according to IEC 60127-2 sheet 1.
Recommendation: Check the safe functioning of the unit after a short circuit.
IN
+
IN
-
A2
A1
2 A
OUT
+
OUT
-
7
8
1
4
3
5
6
2
L1 / L+
1
1: Solenoid valve output


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: IN0131

Heb je hulp nodig?

Als je hulp nodig hebt met IFM IN0131 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM DP4302 Handleiding

12 April 2024
IFM

IFM EVCB02 Handleiding

11 Maart 2024
IFM

IFM EVCB03 Handleiding

11 Maart 2024
IFM

IFM EVF666 Handleiding

11 Maart 2024
IFM

IFM TM4599 Handleiding

8 Januari 2024
IFM

IFM ZB0074 Handleiding

8 Januari 2024
IFM

IFM EVF661 Handleiding

8 Januari 2024
IFM

IFM IIP201 Handleiding

7 Januari 2024
IFM

IFM DP4200 Handleiding

7 Januari 2024
IFM

IFM IIP200 Handleiding

7 Januari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd