Bekijk gratis de handleiding van IFM IF5766 (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 206 mensen en kreeg gemiddeld 4.6 sterren uit 103.5 reviews. Heb je een vraag over IFM IF5766 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/1

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen • Germany • http://www.ifm.com • e-mail:info@ifm.com
UK
80011315 / 00 05 / 2014
Mounting Instructions
Flush mountable tubular switches / CSA Div. 2
Flush mountable switches can be mounted so that the ac-
tive face is flush with a metal surface. Any metal in front
of the switch should be kept at a distance of three times
the nominal sensing range.
s = nominal sensing range
b = maximum thread length
M8 - 8 mm, M12 - 8 mm
M18 - 8 mm, M30 - 16 mm
3xs
b
Two flat nuts are provided to hold the installed switch in
place.
When mounting tubular switches opposite each other, the spacing distance
shown here should be maintained.
Sr = nominal sensing range
8 x Sr
active face
When mounting tubular switches next to each other, the spacing distance
shown here should be maintained.
D = switch diameter
D
DD
active face
active face
CSA for Hazardous Locations
When wired in accordance with CEC and this mounting instructions.
Class I, Div. 2, Groups A, B, C and D
Class II, Div. 2, Groups E, F and G
Class III, T4
Enclosure: Type 4/4x
Temp. range: -13° to 176°F (-25° to 80°C)
ELECTRICAL
DO NOT operate an incandescent light bulb as a load.
The current inrush when the bulb is cold can cause a
current overload.
DO NOT operate a proximity sensor directly from a
voltage supply without a load. This is a short circuit and
can cause damage. Note: insert a miniature fuse accor-
ding to the technical data sheet, if specified.
Concerning Safety... ifm efector makes every effort to build a de-
pendable product, but every product will eventually fail. Therefore,
your equipment must be designed to prevent property damage
and personal injury if our products fail. ifm efector proximity
switches are not designed to be used as stand-alone devices to
protect or guard human life or limb.
WARNING
Explosion Hazard – substitution of components may impair suitability
of Class 1, Div. 2. Do not disconnect while circuit is live unless area is
known to be non-hazardous.
AVERTISSEMENT
Risque d'explosion - La Substitution de composants peut rendre ce
matérielle inacceptable pour les emplacements de classe I division 2.
Ne pas débrancher tant que le circuit est sous tensions, à moins qu'il
ne s'agisse d'un emplacement non dangereux.
CAUTION
Use only ifm efector conduit adapters (U30029, U30030, U30031) or
other CSA ceritifed conduit adapters.
ATTENTION
Utiliser uniquement les adaptateurs tube d'ifm efector (U30029,
U30030, U30031) ou d'autres adaptateurs tube certifiés par CSA.
Product specificaties
Merk: | IFM |
Categorie: | Niet gecategoriseerd |
Model: | IF5766 |
Heb je hulp nodig?
Als je hulp nodig hebt met IFM IF5766 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd IFM
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
23 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
Handleiding Niet gecategoriseerd
- Finnlo
- Alpatronix
- Viessmann
- KED
- Beautifly
- ATen
- Lumag
- ATN
- Ovation
- Hive
- Laserluchs
- Covercraft
- BrightSign
- GRE
- Playtive Junior
Nieuwste handleidingen voor Niet gecategoriseerd
18 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025