Installation instructions
G ½ hygienic fitting adapter
with O-ring / PEEK sealing ring
E43911
80227865 / 00 05 / 2015
UK
2
1 Functions and features
The use of the E43911 kit is required for sensors with G½ hygienic fitting to be in
compliance with 3A requirements.
Use in hygienic areas to 3A requirements:
â–º Make sure that the sensors are integrated into the system in accordance
with 3A.
2 Installation
2.1 Mounting to the sensor
1
A
C
B
â–ºPlace the sealing ring (A) in the groove of
the sensor.
â–ºApply a small amount of lubricating paste
(B) only to the threads to prevent galling.
The paste must be suitable and approved
for the application and compatible with all
components. Prevent the lubricating paste
from coming in contact with the seals.
â–ºPlace the conical sealing ring (C) onto the
conical end of the process adapter. When
installing vertical place conical seal into
the adapter. Ensure the conical seal is
properly aligned.
3
UK
2
D
â–ºScrew the sensor into the adapter (D) until
it is hand-tight. When doing so, ensure
that the conical sealing ring remains in
position against the conical end of the
sensor.
3
E
â–ºClamp the sensor and adapter into a
clamping device (E). Tighten the clamping
device only slightly so that the adapter
does not warp.
â–ºTighten the sensor using a spanner until
you can feel the end stop (this corre-
sponds to a maximum tightening torque
of 25 Nm).
Note: Further tightening may affect the
sealing effect.
To ensure proper sealing use a new conical sealing ring when servicing the
sensor.
2.2 Mounting to the process connection
â–ºWhen the sensor and adapter are fixed to the process connection using a fixing
element (coupling nut, clamp flange, etc.). If it is not possible to slide the fixing
element down over the top of the unit: slide it up over the bottom of the unit
before the adapter is mounted.
3 Technical data and scale drawing
Technical data and scale drawing at www.ifm.com.


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: E43911

Heb je hulp nodig?

Als je hulp nodig hebt met IFM E43911 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM DP4302 Handleiding

12 April 2024
IFM

IFM EVCB02 Handleiding

11 Maart 2024
IFM

IFM EVCB03 Handleiding

11 Maart 2024
IFM

IFM EVF666 Handleiding

11 Maart 2024
IFM

IFM TM4599 Handleiding

8 Januari 2024
IFM

IFM ZB0074 Handleiding

8 Januari 2024
IFM

IFM EVF661 Handleiding

8 Januari 2024
IFM

IFM IIP201 Handleiding

7 Januari 2024
IFM

IFM DP4200 Handleiding

7 Januari 2024
IFM

IFM IIP200 Handleiding

7 Januari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd