IFM E43322 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor IFM E43322 (7 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 127 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/7
Installation instructions
Variable clamp fitting
E43322
E43349
80228529 / 00 05 / 2015
UK
2
1 Safety instructions
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property can occur. That is why installation, set-up
and maintenance of the article must only be carried out by qualified personnel
authorised by the machine operator.
• Before installing and removing the clamp fitting: Make sure that no pressure
is applied to the system and there is no medium in the pipe or the tank. Also
always note the potential dangers related to extreme machine or medium
temperatures.
• Install the security cable (Figure 2) according to the instructions. This secures
the sensor in applications subjected to pressure and with insufficient adhesive
force of the clamp fitting (e.g. with insufficient tightening torque).
• Observe the max. admissible tank pressure: 6 bar
• No changes to the clamp fitting, in particular to the security cable and its
fixtures, must be made.
1.1 General notes
For use in hygienic areas to EHEDG: Adhere to the applicable EHEDG
guideline and the documentation of the respective sensor.
2 Functions and features
• Installation of binary level sensors without dead zone according to table:
Sensor Accessories
LMT104 E43349
LMT105 E43322
• The installation depth of the sensors can be adjusted to suit the individual
application(→2.1Applicationexamples).
The clamp fitting is intended for installation in existing G½ hygienic
adaptations(www.ifm.com→Datasheetsearch→Accessories).
Maximum tank pressure: 6 bar
3
UK
2.1 Application examples
Fig. 1
A
B
C
A : Use as overspill protection, variable setting of the response height.
B : Use in applications with deposits; deeper positioning in the tank.
C : Use in insulated tanks, bridging the insulation layer right into the tank
When mounted in restricted spaces: Adhere to the probe length and the
minimum distances as indicated in the operating instructions of the sensor
to avoid malfunction and damage to the sensor.


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: E43322

Heb je hulp nodig?

Als je hulp nodig hebt met IFM E43322 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM DP4302 Handleiding

12 April 2024
IFM

IFM EVCB02 Handleiding

11 Maart 2024
IFM

IFM EVCB03 Handleiding

11 Maart 2024
IFM

IFM EVF666 Handleiding

11 Maart 2024
IFM

IFM TM4599 Handleiding

8 Januari 2024
IFM

IFM ZB0074 Handleiding

8 Januari 2024
IFM

IFM EVF661 Handleiding

8 Januari 2024
IFM

IFM IIP201 Handleiding

7 Januari 2024
IFM

IFM DP4200 Handleiding

7 Januari 2024
IFM

IFM IIP200 Handleiding

7 Januari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd