Bekijk gratis de handleiding van IFM E37411 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 10 mensen en kreeg gemiddeld 4.5 sterren uit 5.5 reviews. Heb je een vraag over IFM E37411 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
Installation instructions
Welding thermowell
E30403
E374x1
E374x0
80257707 / 00 01 / 2018
UK
ifm electronic gmbh • Friedrichstr. 1 • D 45128 Essen
http://www.ifm.com • e-mail: info@ifm.com
2
1 Welding the thermowell
The welding should only be carried out by qualified personnel.
Use materials and welding operations that are suitable for the housing material.
Use welding techniques according EHEDG requirements (Doc 9) to ensure a
good weld. In order to apply the required 3 mm radius to the inner surface a
second fillet weld is necessary.
Ensure the careful preparation of the components:
- Grind and polish the inside weld to achieve a minimum radius of 3 mm.
- Ensure the surface roughness of Ra ≤ 0.8 μm for optimised cleanability.
2 Welding operation
Apply the fixing points of the thermowell at equal distance (crosswise) with a
sufficient adhesive force.
Apply the welding seams crosswise between the fixing points.
Observe the cooling phases between the individual welding operations.
> They avoid glowing through / warping of the thermowell due to overheating.
Ensure full weld penetration to have no crevice where the weld seam is in
contact with the medium according to EHEDG requirements (Doc 9).
3 After completion of the welding process
Let the workpiece cool down.
Slightly grease the thread using a lubricating paste which is suitable and
approved for the application.
Screw the sensor into the adapter and tighten. Tightening torque: 30...50 Nm.