Bekijk gratis de handleiding van IFM E30406 (3 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 287 mensen en kreeg gemiddeld 4.3 sterren uit 144 reviews. Heb je een vraag over IFM E30406 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/3
Installation Instructions
Voltage converter
E30406
704697 / 00 11 / 2009
UK
2
Safety instructions1
Please read this document prior to set-up of the unit. Ensure that the product is
suitable for your application without any restrictions.
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property can occur.
Functions and features2
The unit provides a 24 V voltage for the supply of sensors in electrical systems
with an operating voltage lower than 24 V.
Electrical connection3
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical
equipment must be adhered to.
Voltage supply according to EN 50178, SELV, PELV.
Disconnect power.
Connect the unit as follows:
4
1
3
2
E30406
4
1
3
2OUT2
L+
L
OUT1
OUT2
OUT1
1 Socket M12 connection to the sensor
2 Plug M12 connection to supply voltage
3
UK
Scale drawing4
58
1 m
1 m
Technical data5
Input voltage [V]..................................................................................................... 9...27 DC
Current consumption max. [mA] ..................................................................................... 500
Sensor supply
Supply voltage [V] .................................................................................................... 24 DC
Operating current max. [mA] ......................................................................................... 125
Materials .................................................................................................... housing: PBT GF
cable: PUR; connector housing: TPU orange;
sealing: Viton; nut: brass nickel-plated
Protection ................................................................................................................ IP 40, III
Ambient temperature [°C] ....................................................................................... -25...70
EMC EN 61000-4-2 ESD: ..................................................................................... 4 / 15 kV
EN 61000-4-3 HF radiated: ................................................. 30 V/m (80...1000 MHz)
EN 61000-4-4 Burst: .................................................................. 2 kV coupling clamp
EN 61000-4-6 HF conducted: .................................................. 10 V (0.15...80 MHz)
Further information at
www.ifm.com Select your country Data sheet direct:→ →


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: E30406

Heb je hulp nodig?

Als je hulp nodig hebt met IFM E30406 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM AL1590 Handleiding

3 September 2025
IFM

IFM AL1591 Handleiding

3 September 2025
IFM

IFM QCM110 Handleiding

2 September 2025
IFM

IFM VMB301 Handleiding

27 Augustus 2025
IFM

IFM PG1709 Handleiding

15 Augustus 2025
IFM

IFM EVC875 Handleiding

15 Augustus 2025
IFM

IFM PG1743 Handleiding

15 Augustus 2025
IFM

IFM EVM045 Handleiding

15 Augustus 2025
IFM

IFM DTI921 Handleiding

15 Augustus 2025
IFM

IFM PG1708 Handleiding

14 Augustus 2025

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd