IFM E21248 Handleiding


Bekijk gratis de handleiding van IFM E21248 (5 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 10 mensen en kreeg gemiddeld 4.8 sterren uit 5.5 reviews. Heb je een vraag over IFM E21248 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/5
706001 / 00 02 / 2011
Installation instructions
O1D Cooling Box
E21248
UK
2
1 Functions and features
The cooling box is a protective housing with an active cooling system for sensors
of the O1D design. It enables sensor operation at high ambient temperatures.
2 Installation
AB
C
D
E
F
G
H
I
J
3
UK
2.1 Installation of the sensor
Loosen the screws (B) and remove the cover (A)
Feed the electrical connection cable through the cable gland (D).
If using a wirable socket, attach this to the cable.
Refer to the sensor and socket data sheets for the correct wiring. Only angled
sockets may be used.
Connect the socket to the sensor (J)
Insert the hexagon nuts (C) in the cut-outs on the sensor
Insert the sensor in the cooling box and push it towards the front lens (H) until
the end stop has been reached.
Fix it using the screws (G)
Tighten the cable gland (D)
Position the cover again and tighten the screws (B)
Prewired connection cables must be fed through the cable gland from the
inside.
You can find mating sockets at:
www.ifm.com → data sheet search → O1D100 → Accessories
The premounted cable gland (D) can be replaced by another fitting with M16
thread, e.g. for attaching a conduit.
2.2 Connection for cooling
Connect the cooling circuit hoses to the nozzles (E). The direction of the cool-
ing medium flow is not important.
Use jubilee clips to avoid the hoses coming loose.
2.3 Fixing the cooling box
Mounting set E3D103 is suited for the installation of the cooling box.
www.ifm.com → data sheet search → E3D103
The mounting holes (F) have an internal M8 thread.