Operating instructions
(Ex protection related part) for inductive sensors
according to EU directive 94/9/EC Annex VIII (ATEX)
group II, equipment category 3D
DI003A, DI004A
DI504A, DI505A, DI506A
UK
UK
UK
UKUK
2
Operating instructions (safety-related part ATEX)
Remarks for safe use in
hazardous areas
Functions and features
• Use in hazardous areas according to the classification
II 3D
(group II, category 3D, apparatus for dust atmosphere).
The requirements of the standards EN60079-0 and EN60079-31 are met.
• Marking (see unit or technical data sheet)
II 3D Ex tc IIIC T80°C Dc IP67 U
• Permissible operating temperature of the application (proper usage):
Ta: -20°C...+50°C
Installation / set-up
The units must only be installed, connected and set up by qualified staff. The qualified staff
must have knowledge of protection classes, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification (see "Marking" above and marking on the unit) is suitable
for the application.
Installation remarks / installation
• Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
• Avoid electrostatic charging on plastic units and cables.
• To avoid electrostatic charging clean the unit with a damp cloth only.
Rubbing with non-conductive materials must be strictly avoided.
• To avoid electrostatic charging steps must be taken to ensure the equalisation of potential
of metal parts (plug housing, fixing elements, protective housing, etc.).
• Do not mount the unit in the dust flow.
• Avoid dust deposits on the units.
• Protect the units and the cables efficiently against damage.
• For the connections and the electrical characteristics please see the unit marking or the
technical data sheet.
• Avoid soiling of the connector area. Attach the socket in a clean environment.
• Avoid direct radiation with high UV components (sunlight).
Mount the unit in a protected place.
• M12 plugs may only be opened or closed in a sufficiently clean environment.
3
UK
Special conditions for safe operation
• The units were tested in combination with the supplied impact protection housing in
accordance with table 8 of EN 60079-0 for group II and for a low mechanical risk with an
impact energy of 4 joules.
• Only operate the units with the supplied impact protection housing.
• Position the impact protection housing (1) so that the operating and display elements of
the unit can be seen through the sight (2) and operating holes (3).
• In case of flush installation ensure that only the sensor face is directly exposed to impacts
up to 4 joules. In case of impacts on the edge (e.g. non-flush installation), mount the
impact protection housing for the sensor (5).
• Tightening torque of the clamp screws (4): 3 Nm ±10%
• Tightening torque of the threaded flange (5): 2.5 Nm ±10%
5
6
1: Impact protection housing
2: Sight hole (LED)
3: Operating hole (potentiometer)
4: Clamp screw M4
5: Threaded fl ange
6: Impact protection housing for the sensor
• Use sockets which are suited for hazardous areas, e.g. ifm sockets EVC**A with Ex
certificate (certificate number BVS 08 ATEX E 109 U).
As an alternative you can also use the ifm sockets EVC490 or EVC491.
• Secure the sockets by tightening the hexagon coupling nut sufficiently according to the
requirements of the Ex protection related operating instructions of the socket.
• Do not separate the connector when energized.
• For cable units ensure a sufficient strain relief or lay the cable securely.
• Only use the operating elements of the units in a dry environment.
• Where units require an additional fuse, this must be located outside the hazardous areas.
Maintenance / repair
The unit must not be modified nor can it be repaired. In case of a fault please contact the
manufacturer.
If required, the technical data sheets and EC declarations of conformity can be obtained
from the manufacturer. Indicate the article number.


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: DI504A

Heb je hulp nodig?

Als je hulp nodig hebt met IFM DI504A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM DP4302 Handleiding

12 April 2024
IFM

IFM EVCB02 Handleiding

11 Maart 2024
IFM

IFM EVCB03 Handleiding

11 Maart 2024
IFM

IFM EVF666 Handleiding

11 Maart 2024
IFM

IFM TM4599 Handleiding

8 Januari 2024
IFM

IFM ZB0074 Handleiding

8 Januari 2024
IFM

IFM EVF661 Handleiding

8 Januari 2024
IFM

IFM IIP201 Handleiding

7 Januari 2024
IFM

IFM DP4200 Handleiding

7 Januari 2024
IFM

IFM IIP200 Handleiding

7 Januari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd